Reliability of the transverse acetabular ligament as a landmark for functional cup anteversion in total hip arthroplasty

被引:0
|
作者
Jassim, Shivan S. [1 ,5 ]
Bhatia, Tejasvi [2 ]
McMahon, Jack R. D. [1 ,3 ]
Pierrepont, Jim W. [4 ]
McMahon, Stephen J. [1 ,3 ]
机构
[1] Malabar Orthopaed Clin, Windsor, Vic, Australia
[2] Bhatia Orthopaed Ctr, Karnal, India
[3] Monash Univ, Melbourne, Vic, Australia
[4] Univ Sydney, Sydney, Australia
[5] Malabar Orthopaed Clin, 43 Ave, Windsor, Vic 3181, Australia
关键词
Anatomy; anteversion; cup orientation; total hip replacement; transverse acetabular ligament; COMPONENT ORIENTATION; REPLACEMENT; DISLOCATION; POSITION; RISK;
D O I
10.1177/11207000241243035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The transverse acetabular ligament (TAL) can be a useful and reproducible landmark in the orientation of the acetabular cup in total hip arthroplasty (THA). Its role in guiding cup orientation when aiming to implant in a functional anteversion orientation is unclear. The aim of this study was to assess the relationship between the TAL and the planned acetabular cup anteversion when implanted in a function orientation. Material and Methods: In a retrospective study the anteversion of the TAL in the contralateral un-replaced hip was measured in CT scans of patients undergoing THA and compared to the functional cup anteversion using the patient-specific spinopelvic parameters. Comparative measurements of the native acetabular version were made from the superior rim to the inferior rim and at 10 mm intervals between the 2, all in reference to the anterior pelvic plane. Results: 96 hips were measured. The mean TAL anteversion angle was 17.2 degrees +/- 4.5 degrees. The mean planned acetabular cup anteversion angle was 26.3 degrees +/- 4.7 degrees. Pearson's correlation coefficient of this measurement with the TAL was -0.03 (p = 0.769). There was a significant difference between the planned acetabular cup anteversion and the measurement of the TAL (p < 0.0001). Conclusions: If cups are implanted parallel to the TAL, almost 80% will be >5 degrees different to targeted functional cup version. It should be aimed to implant cups with more anteversion than the TAL indicates.
引用
收藏
页码:608 / 613
页数:6
相关论文
共 50 条
  • [31] Relation of native acetabular anteversion to the orientation of transverse acetabular ligament
    Kuchar, Michal
    Pelc, Ondrej
    Moravek, Alexander
    Henys, Petr
    Heinemann, Axel
    Ondruschka, Benjamin
    Kucera, Tomas
    HIP INTERNATIONAL, 2024, 34 (06) : 754 - 763
  • [32] Exposing the transverse acetabular ligament in the presence of large floor osteophytes in primary total hip arthroplasty
    Sun, Huaqiang
    Li, Shufeng
    He, Yeteng
    Wang, Teng
    Yu, Zhaolong
    Yan, Xinfeng
    HIP INTERNATIONAL, 2016, 26 (05) : 498 - 502
  • [33] A precise method for determining acetabular component anteversion after total hip arthroplasty
    Murphy, M. P.
    Killen, C. J.
    Ralles, S. J.
    Brown, N. M.
    Hopkinson, W. J.
    Wu, K.
    BONE & JOINT JOURNAL, 2019, 101B (09): : 1042 - 1049
  • [34] The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty
    Shin, W. C.
    Lee, S. M.
    Lee, K. W.
    Cho, H. J.
    Lee, J. S.
    Suh, K. T.
    BONE & JOINT JOURNAL, 2015, 97B (05): : 611 - 616
  • [35] Use of a sentinel pin as a guide to acetabular component anteversion in total hip arthroplasty
    Goldstein, Wayne M.
    Jimenez, Matthew L.
    Gordon, Alexander C.
    Branson, Jill Jasperson
    Berland, Kimberly
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 97 - 100
  • [36] RADIOLOGICAL MEASUREMENT OF THE ANTEVERSION OF THE ACETABULAR CUP AFTER CHARNLEY TOTAL HIP-REPLACEMENT
    CHEVROT, A
    NAJMAN, G
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1983, 69 (06): : 483 - 485
  • [37] Influence of sagittal degenerative spondylolisthesis on anteversion of the acetabular component in total hip arthroplasty
    Shen, Kaiwei
    Lin, Liqiong
    Feng, Eryou
    Zhang, Yiyuan
    Xiao, Lili
    Lin, Feitai
    Li, Zhanglai
    ORTHOPADE, 2021, 50 (08): : 664 - 673
  • [38] Sagittal Imbalance Does Not Influence Cup Anteversion in Total Hip Arthroplasty Dislocations
    Haws, Brittany E.
    Khechen, Benjamin
    Patel, Dil, V
    Louie, Philip K.
    Iyer, Sravisht
    Cardinal, Kaitlyn L.
    Guntin, Jordan A.
    Singh, Kern
    CLINICAL SPINE SURGERY, 2019, 32 (01): : E31 - E36
  • [39] EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING
    GOERGEN, TG
    RESNICK, D
    BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568): : 259 - 260
  • [40] The influence of sagittal spinal deformity on anteversion of the acetabular component in total hip arthroplasty
    Phan, D.
    Bederman, S. S.
    Schwarzkopf, R.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1017 - 1023