Experimental Study on Direct Shear Strength of Fiber Reinforced Self Compacting Concrete under Acid and Sulfate Attack

被引:0
作者
Awrahman, Ahmad Haydar [1 ]
Eren, Necip Altay [2 ]
Cevik, Abdulkadir [1 ]
Mohammed, Azad Abdulkadir [3 ]
机构
[1] Gaziantep Univ, Fac Engn, Dept Civil Engn, TR-27310 Gaziantep, Turkiye
[2] Gaziantep Univ, Tech Sci Vocat Sch, Dept Construct, TR-27310 Gaziantep, Turkiye
[3] Univ Sulaimani, Coll Engn, Civil Engn Dept, Zone 501 Sulaimani, Sulaymaniyah, Kurdistan, Iraq
来源
PERIODICA POLYTECHNICA-CIVIL ENGINEERING | 2024年 / 68卷 / 02期
基金
英国科研创新办公室;
关键词
fiber reinforced self-compacting concrete; polypropylene fiber; steel fiber; direct shear strength; workability; SKIN FRICTION; PERFORMANCE;
D O I
10.3311/PPci.22519
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study primary is to investigate the shear strength of self-compacting concrete (SCC) reinforced by steel-fiber (SF) and polypropylene-fiber (PPF) in different environmental conditions: the air, sulfate (MgSO4 with a concentration of 5%) and acid (H2SO4 with a concentration of 5%). The study also examines the effect of fiber volume fraction on the workability, shear strength, compressive strength, and splitting tensile strength of fiber reinforced SCC. The article aims to determine the durability effects of both fibers and their resistance to aggressive environmental conditions. The contribution of this article is an experimental investigation on the shear strength of SCC reinforced by SF as well as PPF in 3 different environmental conditions after 30 days of exposure. The study also investigated the fresh and mechanical properties of 5 different mixtures of SCC with/out 0.1% and 0.2% fibers. The study also concluded that PPF decreased the workability of SCC badly, and special care must be taken when selecting its volume fraction. Also, it was found that generally shear strength of SCC mixes enhanced with increasing SF and PPF volume fraction. Moreover, it was found that both fibers have good durability effects, and resist aggressive environmental conditions, with the best results obtained from samples containing 0.2% SF. In the air condition, while the compressive strength, shear strength and tensile strength results were 52.6MPa, 6.43MPa and 3.91MPa, in the sulfate condition those were 46.37MPa, 6.55MPa and 3.59MPa, and in the acid condition those were 34.4MPa, 5.5MPa and 3.46MPa, respectively.
引用
收藏
页码:392 / 402
页数:11
相关论文
共 42 条
  • [1] ACI Committee 318, 2011, ACI 318-011) and Commentary (ACI 318R-11)
  • [2] AHMED S., 2006, 31 C OUR WORLD CONCR, P63
  • [3] AL-Ameeri A., 2013, AM J CIVIL ENG, V1, P102
  • [4] Amin MM, 2008, PORT ELECTROCHIM ACT, V26, P235
  • [5] [Anonymous], 2019, 52019 IOS
  • [6] [Anonymous], 2016, 2123R16 ACI
  • [7] [Anonymous], 2007, Self-Consolidating Concrete (ACI 237R-04)
  • [8] [Anonymous], 2017, ASTM C39/C39M-21, P1, DOI [DOI 10.1520/C0039, DOI 10.1520/C0039C0039M-21, 10.1520/C0039C0039M-21, DOI 10.1520/C0150]
  • [9] ASTM, 2005, C1611C1611M05 ASTM, DOI [10.1520/C1611_C1611M-05, DOI 10.1520/C1611_C1611M-05]
  • [10] ASTM International, 2002, STANDARD TEST METHOD, P1, DOI [DOI 10.1520/D4318-17E01, 10.1520/D079017.2]