The applicability of decentralized ventilation equipment in radon mitigation from existing homes

被引:0
|
作者
Mares, I. C. [1 ]
Catalina, T. [1 ]
机构
[1] Tech Univ Civil Engn Bucharest, Fac Engn Installat, Bucharest, Romania
来源
8TH CONFERENCE OF THE SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT EENVIRO 2022 | 2023年 / 1185卷
关键词
INDOOR RADON; SOIL; HOUSE;
D O I
10.1088/1755-1315/1185/1/012011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article exposes the results of radon mitigation in existing homes using decentralized ventilation equipment with heat recovery. The experimental measurement has been conducted in a large study about radon mitigation from existing homes in Romania Various methods were treated separately to clearly expose the advantages and disadvantages for each method applied. This article focusses on the use of decentralized mechanical ventilation equipment with heat recovery. The analyzed dwelling is located in Cluj County, a radon prone area located in the west part of Romania The preliminary measurements shown a high radon level inside the analyzed house. To prevent the high radon accumulation in the analyzed dwelling, a decentralized ventilation equipment was installed. The mean radon level inside the house decreases from 510 Bq/m3 (value recorded one year before mitigation), to approximately 361 Bq/m3 after the mitigation methods were applied, showing an reduction efficiency of approximately 30%.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] Testing radon mitigation techniques in a pilot house from Baita-Stei radon prone area (Romania)
    Cosma, Constantin
    Papp, Botond
    Cucos , Alexandra
    Sainz, Carlos
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 140 : 141 - 147
  • [2] Radon gas emission from home appliances: Understanding sources, implications, and mitigation strategies
    Abed, Talib K.
    Fayad, Mohammed A.
    Al-Amiery, Ahmed A.
    Wahhab, Hasanain A. Abdul
    Mohammed, Jabbar K.
    Majdi, Hassan Sh.
    RESULTS IN ENGINEERING, 2024, 22
  • [3] No flow meter method for measuring radon exhalation from the medium surface with a ventilation chamber
    Tan, Yanliang
    Yuan, Hongzhi
    Xie, Yuxi
    Liu, Can
    Liu, Xiaosong
    Fan, Zhongkai
    Kearfott, Kimberlee
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [4] Radiometric evaluation of indoor radon levels with influence of building characteristics in residential homes from southwestern Nigeria
    Kehinde Aladeniyi
    Adeseye Muyiwa Arogunjo
    Alcides J. S. C. Pereira
    Oladele Samuel Ajayi
    Ibiyinka Agboola Fuwape
    Environmental Monitoring and Assessment, 2020, 192
  • [5] Radiometric evaluation of indoor radon levels with influence of building characteristics in residential homes from southwestern Nigeria
    Aladeniyi, Kehinde
    Arogunjo, Adeseye Muyiwa
    Pereira, Alcides J. S. C.
    Ajayi, Oladele Samuel
    Fuwape, Ibiyinka Agboola
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (12)
  • [6] Comprehensive survey on radon mitigation and indoor air quality in energy efficient buildings from Romania
    Burghele, B. D.
    Botos, M.
    Beldean-Galea, S.
    Cucos, A.
    Catalina, T.
    Dicu, T.
    Dobrei, G.
    Florica, S.
    Istrate, A.
    Lupulescu, A.
    Moldovan, M.
    Nita, D.
    Papp, B.
    Pap, I.
    Szacsvai, K.
    Sainz, C.
    Tunyagi, A.
    Tenter, A.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 751