Navigation in reverse shoulder arthroplasty: how the lateralization of glenosphere can affect the clinical outcome

被引:5
作者
Tarallo, Luigi [1 ]
Giorgini, Andrea [1 ]
Micheloni, Gianmario [1 ]
Montanari, Marta [1 ]
Porcellini, Giuseppe [1 ]
Catani, Fabio [1 ]
机构
[1] Univ Modena & Reggio Emilia Modena, Orthoped & Traumatol Dept, Via Pozzo 71, I-41125 Modena, Italy
关键词
RSA navigation system; Glenosphere lateralization; COMPLICATIONS; ARTHRITIS; REVISION; DESIGN; RANGE;
D O I
10.1007/s00402-023-04879-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionOne of the main causes of RSA failure is attributable to the malpositioning of the glenoid component. Initial experiences with computer-assisted surgery have shown promising results in increasing the accuracy and repeatability of placement of the glenoid component and screws. The aim of this study was to evaluate the functional clinical results, in terms of joint mobility and pain, by correlating them with intraoperative data regarding the positioning of the glenoid component. The hypothesis was that the lateralization more than 25 mm of the glenosphere can led to better stability of the prosthesis but should pay in term of a reduced range of movement and increased pain.Materials and methods50 patients were enrolled between October 2018 and May 2022; they underwent RSA implantation assisted by GPS navigation system. Active ROM, ASES score and VAS pain scale were recorded before surgery. Preoperative data about glenoid inclination and version were collected by pre-op X-Rays an CT. Intraoperative data-inclination, version, medialization and lateralization of the glenoid component-were recorded using computer-assisted surgery. 46 patients had been further clinically and radiographically re-evaluated at 3-months, 6-months, 1-year, and 2-years follow-up.ResultsWe found a statistically significant correlation between anteposition and glenosphere lateralization value (DM - 6.057 mm; p = 0.043). Furthermore a statistically significant correlation has been shown between abduction movement and the lateralization value (DM - 7.723 mm; p = 0.015). No other statistically significant associations were found when comparing the values of glenoid inclination and version with the range of motion achieved by the patients after reverse shoulder arthroplasty.ConclusionWe observed that the patients with the best anteposition and abduction results had a glenosphere lateralization between 18 and 22 mm. When increasing the lateralization above 22 mm or reducing it below 18 mm, on the other hand, both movements considered decreased their range.
引用
收藏
页码:5649 / 5656
页数:8
相关论文
共 50 条
  • [31] Early clinical and radiological outcomes of reverse shoulder arthroplasty with an eccentric all-polyethylene glenosphere to treat failed hemiarthroplasty and the sequelae of proximal humeral fractures
    Merolla, Giovanni
    Tartarone, Antonio
    Sperling, John W.
    Paladini, Paolo
    Fabbri, Elisabetta
    Porcellini, Giuseppe
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (01) : 141 - 148
  • [32] Does glenohumeral offset affect clinical outcomes in a lateralized reverse total shoulder arthroplasty?
    Wolf, G. Jacob
    Reid, Jared J.
    Rabinowitz, Justin R.
    Barcel, D. Anthony
    Barfield, William R.
    Eichinger, Josef K.
    Friedman, Richard J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (01) : 50 - 58
  • [33] Lateralization in reverse shoulder arthroplasty: a descriptive analysis of different implants in current practice
    Werthel, Jean-David
    Walch, Gilles
    Vegehan, Emilie
    Deransart, Pierric
    Sanchez-Sotelo, Joaquin
    Valenti, Philippe
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) : 2349 - 2360
  • [34] The use of an eccentric glenosphere compared with a concentric glenosphere in reverse total shoulder arthroplasty: two-year minimum follow-up results
    De Biase, Carlo Felice
    Ziveri, Giovanni
    Delcogliano, Marco
    de Caro, Francesca
    Gumina, Stefano
    Borroni, Mario
    Castagna, Alessandro
    Postacchini, Roberto
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) : 1949 - 1955
  • [35] Finite element analysis of glenoid-sided lateralization in reverse shoulder arthroplasty
    Denard, Patrick J.
    Lederman, Evan
    Parsons, Bradford O.
    Romeo, Anthony A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (07) : 1548 - 1555
  • [36] Comparative Analysis of Eccentric Glenosphere in Reverse Total Shoulder Arthroplasty A Computer Simulation Study
    Xu, Xiaopei
    Sun, Qingnan
    Liu, Yang
    Wang, Dong
    Diao, Shuo
    Wang, Hanzhou
    Gao, Yuling
    Lu, Tianchao
    Zhou, Junlin
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 4691 - 4704
  • [37] How Reverse Shoulder Arthroplasty Works
    Walker, Matthew
    Brooks, Jordan
    Willis, Matthew
    Frankle, Mark
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) : 2440 - 2451
  • [38] Reverse shoulder arthroplasty for fracture sequelae: Clinical outcome and prognostic factors
    Pastor, Marc-Frederic
    Kieckbusch, Max
    Kaufmann, Melena
    Ettinger, Max
    Wellmann, Mathias
    Smith, Tomas
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (02) : 237 - 242
  • [39] Difference in clinical outcome between total shoulder arthroplasty and reverse shoulder arthroplasty used in hemiarthroplasty revision surgery
    Hartel, Bas Pieter
    Alta, Tjarco D.
    Sewnath, Miguel E.
    Willems, Willem J.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2015, 9 (03): : 69 - 73
  • [40] Posterior and inferior glenosphere position in reverse total shoulder arthroplasty supports deltoid efficiency for shoulder flexion and elevation
    Meisterhans, Michel
    Bouaicha, Samy
    Meyer, Dominik C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (08) : 1515 - 1522