Navigation in reverse shoulder arthroplasty: how the lateralization of glenosphere can affect the clinical outcome

被引:5
作者
Tarallo, Luigi [1 ]
Giorgini, Andrea [1 ]
Micheloni, Gianmario [1 ]
Montanari, Marta [1 ]
Porcellini, Giuseppe [1 ]
Catani, Fabio [1 ]
机构
[1] Univ Modena & Reggio Emilia Modena, Orthoped & Traumatol Dept, Via Pozzo 71, I-41125 Modena, Italy
关键词
RSA navigation system; Glenosphere lateralization; COMPLICATIONS; ARTHRITIS; REVISION; DESIGN; RANGE;
D O I
10.1007/s00402-023-04879-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionOne of the main causes of RSA failure is attributable to the malpositioning of the glenoid component. Initial experiences with computer-assisted surgery have shown promising results in increasing the accuracy and repeatability of placement of the glenoid component and screws. The aim of this study was to evaluate the functional clinical results, in terms of joint mobility and pain, by correlating them with intraoperative data regarding the positioning of the glenoid component. The hypothesis was that the lateralization more than 25 mm of the glenosphere can led to better stability of the prosthesis but should pay in term of a reduced range of movement and increased pain.Materials and methods50 patients were enrolled between October 2018 and May 2022; they underwent RSA implantation assisted by GPS navigation system. Active ROM, ASES score and VAS pain scale were recorded before surgery. Preoperative data about glenoid inclination and version were collected by pre-op X-Rays an CT. Intraoperative data-inclination, version, medialization and lateralization of the glenoid component-were recorded using computer-assisted surgery. 46 patients had been further clinically and radiographically re-evaluated at 3-months, 6-months, 1-year, and 2-years follow-up.ResultsWe found a statistically significant correlation between anteposition and glenosphere lateralization value (DM - 6.057 mm; p = 0.043). Furthermore a statistically significant correlation has been shown between abduction movement and the lateralization value (DM - 7.723 mm; p = 0.015). No other statistically significant associations were found when comparing the values of glenoid inclination and version with the range of motion achieved by the patients after reverse shoulder arthroplasty.ConclusionWe observed that the patients with the best anteposition and abduction results had a glenosphere lateralization between 18 and 22 mm. When increasing the lateralization above 22 mm or reducing it below 18 mm, on the other hand, both movements considered decreased their range.
引用
收藏
页码:5649 / 5656
页数:8
相关论文
共 50 条
  • [21] Reverse Total Shoulder Arthroplasty Biomechanical Considerations and the Concept of Lateralization
    Luthringer, Tyler A.
    Larose, Gabriel
    Kwon, Young
    Zuckerman, Joseph D.
    Virk, Mandeep S.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2022, 80 (01): : 65 - 74
  • [22] Does arm lengthening affect the functional outcome in onlay reverse shoulder arthroplasty?
    Werner, Birgit S.
    Ascione, Francesco
    Bugelli, Giulia
    Walch, Gilles
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (12) : 2152 - 2157
  • [23] Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome?
    Holschen, Malte
    Kiriazis, Alexandros
    Bockmann, Benjamin
    Schulte, Tobias L.
    Witt, Kai-Axel
    Steinbeck, Jorn
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (02) : 307 - 315
  • [24] Treatment of proximal humerus fractures using reverse shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical outcome and tuberosity healing?
    Holschen, Malte
    Koerting, Maria
    Khourdaji, Patrick
    Bockmann, Benjamin
    Schulte, Tobias L.
    Witt, Kai-Axel
    Steinbeck, Joern
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (12) : 3817 - 3826
  • [25] Does Humeral Component Lateralization in Reverse Shoulder Arthroplasty Affect Rotator Cuff Torque? Evaluation in a Cadaver Model
    Chan, Kevin
    Langohr, G. Daniel G.
    Mahaffy, Matthew
    Johnson, James A.
    Athwal, George S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (10) : 2564 - 2571
  • [26] Biomechanical consequences of glenoid and humeral lateralization in reverse total shoulder arthroplasty
    Liu, Bei
    Kim, Young Kyu
    Nakla, Andrew
    Chung, Min-Shik
    Kwak, Daniel
    McGarry, Michelle H.
    Lee, Thay Q.
    Oh, Joo Han
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (08) : 1662 - 1672
  • [27] Reverse shoulder arthroplasty glenoid lateralization influences scapular spine strains
    Kerrigan, Alicia M.
    Reeves, Jake
    Langohr, G. Daniel G.
    Johnson, James A.
    Athwal, George S.
    SHOULDER & ELBOW, 2021, 13 (06) : 610 - 619
  • [28] Assessing glenosphere position: superior approach versus deltopectoral for reverse shoulder arthroplasty
    Aibinder, William R.
    Clark, Nicholas J.
    Schoch, Bradley S.
    Steinmann, Scott P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (03) : 455 - 462
  • [29] A nondestructive method to verify the glenosphere-baseplate assembly in reverse shoulder arthroplasty
    Leuridan, Steven
    Goossens, Quentin
    Pastrav, Leonard
    Van Tongel, Alexander
    De Wilde, Lieven
    Debeer, Philippe
    Denis, Kathleen
    Desmet, Wim
    Sloten, Jos Vander
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : E156 - E165
  • [30] The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion
    Langohr, G. Daniel G.
    Giles, Joshua W.
    Athwal, George S.
    Johnson, James A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (06) : 972 - 979