A new heating system for the air pre-purification of air separation units

被引:11
|
作者
Zhang, Peikun [1 ]
Liang, Jiayue [1 ]
Yang, Yuehan [1 ]
Wang, Li [1 ]
机构
[1] Univ Sci & Technol, Sch Energy & Environm Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Air separation unit; Air pre-purification unit; Thermal regeneration; Energy-saving; SWING ADSORPTION PROCESS; PACKED-BEDS; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.120194
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new heating system is disclosed to reduce the regeneration heating electric consumption for air prepurification of air separation units. The new heating system is of great energy-saving significance, as air separation units are energy-intensive installations that account for a considerable proportion (around 4.97 %) of China's total national electricity consumption. Unlike the traditional electric heater, the new heating system integrates components such as a compressor, a heat exchanger, and an expander to meet the heat requirement of the pre-purification unit, while also providing cooling capacity to reduce the refrigeration load of the pre-cooling system of an air separation unit, thereby realizing the efficient comprehensive utilization of electric energy. Furthermore, a regenerator is employed to enable the continuous operation and downsizing of the system. Mathematical models were established for each process in the new heating system, and then the simulation and calculation were carried out based on the field data of an industrial-scale air separation unit. Inlet and outlet parameters and power of the compressor, expander, and heat exchanger were obtained. The temperature and pressure bed profiles of the regenerator and the temperature history curves of the cold and hot ends of the regenerator were obtained. Then, the energy-saving effect of the new heating system relative to the traditional electric heater was obtained. In addition, an economic evaluation of the new heating system was conducted based on its energy-saving effect. The conclusions drawn are as follows: compared with a traditional electric heater, the new heating system can save about 55.5 % of electric energy, and the payback period of the new heating system retrofitted from a traditional electric heater is about 2.3 years.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Waste heat recovery method for the air pre-purification system of an air separation unit
    Tong, L. G.
    Zhang, P.
    Yin, S. W.
    Zhang, P. K.
    Liu, C. P.
    Li, N.
    Wang, L.
    APPLIED THERMAL ENGINEERING, 2018, 143 : 123 - 129
  • [2] Flexible Operation of Air Separation Units
    Klein, Harald
    Fritsch, Philipp
    Haider, Patrick
    Kender, Robert
    Roessler, Felix
    Rehfeldt, Sebastian
    Freko, Pascal
    Hoffmann, Rainer
    Thomas, Ingo
    Wunderlich, Bernd
    CHEMBIOENG REVIEWS, 2021, 8 (04): : 357 - 374
  • [3] Flexible Operation of Air Separation Units
    Klein, Harald
    Fritsch, Philipp
    Haider, Patrick
    Kender, Robert
    Roessler, Felix
    Rehfeldt, Sebastian
    Freko, Pascal
    Hoffmann, Rainer
    Thomas, Ingo
    Wunderlich, Bernd
    CHEMIE INGENIEUR TECHNIK, 2020, 92 (12) : 1921 - 1940
  • [4] Thermodynamic analysis of an organic Rankine-vapor compression cycle (ORVC) assisted air compression system for cryogenic air separation units
    Zhou, Xia
    Rong, Yangyiming
    Fang, Song
    Wang, Kai
    Zhi, Xiaoqin
    Qiu, Limin
    Chi, Xuelin
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [5] Air Separation, flue gas compression and purification units for oxy-coal combustion systems
    Tranier, Jean-Pierre
    Dubettier, Richard
    Darde, Arthur
    Perrin, Nicolas
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 966 - 971
  • [6] Preemptive Dynamic Operation of Cryogenic Air Separation Units
    Cao, Yanan
    Swartz, Christopher L. E.
    Flores-Cerrillo, Jesus
    AICHE JOURNAL, 2017, 63 (09) : 3845 - 3859
  • [7] Type selection and maintenance of the control system of large-scale air separation units
    DONG Zhenning Energy & Environment Department
    Baosteel Technical Research, 2009, 3 (03) : 13 - 17
  • [8] Thermoeconomic analysis on a cascade energy utilization system for compression heat in air separation units
    Rong, Yangyiming
    Zhi, Xiaoqin
    Wang, Kai
    Zhou, Xia
    Cheng, Xingwang
    Qiu, Limin
    Chi, Xuelin
    ENERGY CONVERSION AND MANAGEMENT, 2020, 213
  • [9] Oxygen Specific Power Consumption Comparison for Air Separation Units
    Alsultanny, Yas A.
    Al-Shammari, Nayef N.
    ENGINEERING JOURNAL-THAILAND, 2014, 18 (02): : 67 - 80
  • [10] Ventilation Pre-heating Effectiveness of a PCM Solar Air Collector with Ventilated Window System
    Hu, Yue
    Heiselberg, Per Kvols
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1700 - 1707