Impact of time off anticoagulation in patients with continuous-flow left ventricular assist devices

被引:2
|
作者
Inchaustegui, Christian A. [1 ,7 ,8 ]
Patel, Ashley [1 ]
Lamba, Harveen K. [2 ]
Brown, Andrew [1 ]
Arunthamakun, Justin [1 ]
Ting, Kevin [1 ]
Chatterjee, Subhasis [3 ,4 ,5 ]
Nair, Ajith P. [6 ]
George, Joggy K. [5 ,6 ]
Shafii, Alexis E. [2 ,3 ]
Liao, Kenneth K. [2 ]
Civitello, Andrew B. [2 ,5 ,6 ]
机构
[1] Baylor Coll Med, Dept Med, McNair Campus MCHA A10-193 MS BCM903, Houston, TX 77040 USA
[2] Baylor Coll Med, Michael E DeBakey Dept Surg, Div Cardiothorac Transplantat & Circulatory Suppo, Houston, TX 77030 USA
[3] Baylor Coll Med, Michael E DeBakey Dept Surg, Div Cardiothorac Surg, Houston, TX 77030 USA
[4] Baylor Coll Med, Michael E DeBakey Dept Surg, Div Gen Surg, Houston, TX 77030 USA
[5] Texas Heart Inst, Houston, TX 77025 USA
[6] Baylor Coll Med, Dept Med, Div Cardiol, Houston, TX 77030 USA
[7] Texas Heart Inst, Dept Cardiopulm Transplantat, 6770 Bertner Ave, Houston, TX 77030 USA
[8] Texas Heart Inst, Ctr Cardiac Support, 6770 Bertner Ave, Houston, TX 77030 USA
关键词
Ventricular assist device; Anticoagulation; End-stage heart failure; Thrombosis; VON-WILLEBRAND SYNDROME; HEART; SOCIETY; WARFARIN; OUTCOMES; SUPPORT; LONG;
D O I
10.1007/s10047-022-01367-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patients with left ventricular assist devices (LVADs) receive anticoagulation to decrease the risk of thrombosis. Various circumstances require discontinuing anticoagulation in LVAD patients, but the risks entailed are not well defined. In a retrospective review of LVAD implantation procedures, we examined the effect of time off anticoagulation on thrombosis and mortality rates after implantation. An international normalized ratio <= 1.5 was used to screen for patients taken off anticoagulation. Patients were divided into three groups by the cumulative number of days off anticoagulation: no discontinuation, short-term discontinuation (< 30 days), and long-term discontinuation (>= 30 days). Rates of ischemic stroke, pump thrombosis, and mortality were compared among groups. Of 245 patients who underwent LVAD implantation during the study, 70 (28.6%) were off anticoagulation during follow-up: 37 (15.1%) had short-term discontinuation (median, 11 days), and 33 (13.5%) had long-term discontinuation (median, 124 days). Patients with long-term discontinuation had a higher rate of ischemic stroke (adjusted hazard ratio 8.5, p = 0.001) and death (adjusted hazard ratio 3.9, p = 0.001). The three groups did not differ in pump thrombosis rate. We conclude that after LVAD implantation, discontinuing anticoagulation for >= 30 days is independently associated with an increased risk of ischemic stroke and death.
引用
收藏
页码:275 / 286
页数:12
相关论文
共 50 条
  • [21] Impact of the HeartMate 3 continuous-flow left ventricular assist device in patients with small body size
    Tonai, Kohei
    Fukushima, Satsuki
    Tadokoro, Naoki
    Kainuma, Satoshi
    Kawamoto, Naonori
    Kakuta, Takashi
    Koga-Ikuta, Ayumi
    Watanabe, Takuya
    Seguchi, Osamu
    Tsukamoto, Yasumasa
    Fukushima, Norihide
    Fujita, Tomoyuki
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 34 (05) : 902 - 908
  • [22] Noninvasive measurement of arterial blood pressure in patients with continuous-flow left ventricular assist devices: a systematic review
    Alvarez, Paulino A.
    Ponnapureddy, Rakesh
    Voruganti, Dinesh
    Duque, Ernesto Ruiz
    Briasoulis, Alexandros
    HEART FAILURE REVIEWS, 2021, 26 (01) : 47 - 55
  • [23] Continuous-flow left ventricular assist devices induce Left ventricular reverse remodeling
    Jacobs, Steven
    Geens, Jef
    Rega, Filip
    Burkhoff, Daniel
    Meyns, Bart
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04) : 466 - 468
  • [24] Cerebrovascular events in children on intracorporeal continuous-flow left ventricular assist devices
    Sert, Dogan Emre
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    Karahan, Mehmet
    Beyazal, Osman Fehmi
    Akdi, Mustafa
    Yilmaz, Abdulkadir
    Catav, Zeki
    ARTIFICIAL ORGANS, 2020, 44 (12) : 1251 - 1258
  • [25] Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices
    Frazier, O. H.
    Baldwin, Andrew C. W.
    Demirozu, Zumrut T.
    Segura, Ana Maria
    Hernandez, Ruben
    Taegtmeyer, Heinrich
    Mallidi, Hari
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06) : 766 - 772
  • [26] Functional and haemodynamic recovery after implantation of continuous-flow left ventricular assist devices in comparison with pulsatile left ventricular assist devices in patients with end-stage heart failure
    Pruijsten, Ralph V.
    Lok, Sjoukje I.
    Kirkels, Hans H.
    Klopping, Corinne
    Lahpor, Jaap R.
    de Jonge, Nicolaas
    EUROPEAN JOURNAL OF HEART FAILURE, 2012, 14 (03) : 319 - 325
  • [27] Characteristics of Ventricular Tachycardia Ablation in Patients With Continuous Flow Left Ventricular Assist Devices
    Sacher, Frederic
    Reichlin, Tobias
    Zado, Erica S.
    Field, Michael E.
    Viles-Gonzalez, Juan F.
    Peichl, Petr
    Ellenbogen, Kenneth A.
    Maury, Philippe
    Dukkipati, Srinivas R.
    Picard, Francois
    Kautzner, Josef
    Barandon, Laurent
    Koneru, Jayanthi N.
    Ritter, Philippe
    Mahida, Saagar
    Calderon, Joachim
    Derval, Nicolas
    Denis, Arnaud
    Cochet, Hubert
    Shepard, Richard K.
    Corre, Jerome
    Coffey, James O.
    Garcia, Fermin
    Hocini, Meleze
    Tedrow, Usha
    Haissaguerre, Michel
    d'Avila, Andre
    Stevenson, William G.
    Marchlinski, Francis E.
    Jais, Pierre
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) : 592 - 597
  • [28] Gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A comprehensive review
    Del Rio-Pertuz, Gaspar
    Nair, Nandini
    ARTIFICIAL ORGANS, 2023, 47 (01) : 12 - 23
  • [29] Outcomes from a recovery protocol for patients with continuous-flow left ventricular assist devices
    Knierim, Jan
    Heck, Roland
    Pieri, Marina
    Schoenrath, Felix
    Soltani, Sajjad
    Stawowy, Philipp
    Dreysse, Stephan
    Stein, Julia
    Mueller, Marcus
    Mulzer, Johanna
    Dandel, Michael
    Falk, Volkmar
    Krabatsch, Thomas
    Potapov, Evgenij
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04) : 440 - 448
  • [30] Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics
    Karahan, Mehmet
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    Sert, Dogan Emre
    Aygun, Emre
    Tola, Muharrem
    Demirkan, Burcu
    Mungan, Semra
    Kursun, Oguzhan
    Catav, Zeki
    Pac, Mustafa
    ARTIFICIAL ORGANS, 2020, 44 (05) : 457 - 464