Closed-Loop Insulin Delivery May Help Prevent Metabolic Complications During Bariatric Surgery in Patients with Type 1 Diabetes: A Case Report

被引:0
作者
Cornu, Erika [1 ]
Gaulier, Camille [2 ]
Juttet, Pauline [1 ]
Beauvy, Julie [1 ]
Mezzarobba, Vincent [1 ]
Proust, Anne-Laure [2 ]
Le Berre, Jean-Philippe [1 ]
Paepegaey, Anne-Cecile [1 ,3 ]
机构
[1] Medipole, Dept Endocrinol, Lyon Villeurbanne, Villeurbanne, France
[2] Medipole, Dept Endocrinol Surg, Lyon Villeurbanne, Villeurbanne, France
[3] Meipole Lyon Villeurbanne, Dept Endocrinol, 158 Ave Leon Blum, F-69100 Villeurbanne, France
关键词
Closed-loop system; Closed-loop insulin delivery; Bariatric surgery; Type; 1; diabetes; Case report; OBESE-PATIENTS;
D O I
10.1089/dia.2023.0551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Obesity in patients with type 1 diabetes (T1D) may worsen their prognosis. Bariatric surgery in these patients can be associated with complications such as diabetic ketoacidosis and severe hypoglycemic episodes. Closed-loop insulin delivery could be a solution to avoid them.Case Report: A 45-year-old woman with T1D and obesity (body mass index of 38.4 kg/m2) was included in our preoperative course of bariatric surgery. Three months before surgery, a closed-loop insulin delivery was instituted due to one prior severe hypoglycemia. Patient did not have immediate or late postoperative hypoglycemia despite consuming a weak amount of carbohydrate. Three months after surgery glycemic control was on target with 86% of time in range 70-180 mg/dL and no time below 70 mg/dL.Conclusion: This case report shows that the use of a closed-loop insulin delivery made it possible to perform bariatric surgery in complete safety for our patient.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 50 条
  • [21] Insulin Requirements According to Sex and Weight in a Population of 9036 Adult Persons With Type 1 Diabetes Using Closed-Loop Insulin Delivery
    Lebbad, Hocine
    Desir, Chesner
    Vesin, Aurelien
    Adenis, Alice
    Charpentier, Guillaume
    Benhamou, Pierre-Yves
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [22] Short-term fully closed-loop insulin delivery using faster insulin aspart compared with standard insulin aspart in type 2 diabetes
    Bally, Lia
    Herzig, David
    Ruan, Yue
    Wilinska, Malgorzata E.
    Semmo, Mariam
    Vogt, Andreas
    Wertli, Maria M.
    Vogt, Bruno
    Stettler, Christoph
    Hovorka, Roman
    DIABETES OBESITY & METABOLISM, 2019, 21 (12) : 2718 - 2722
  • [23] Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes
    Garg, Satish K.
    Weinzimer, Stuart A.
    Tamborlane, William V.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Bailey, Timothy S.
    Brazg, Ronald L.
    Ilany, Jacob
    Slover, Robert H.
    Anderson, Stacey M.
    Bergenstal, Richard M.
    Grosman, Benyamin
    Roy, Anirban
    Cordero, Toni L.
    Shin, John
    Lee, Scott W.
    Kaufman, Francine R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) : 155 - 163
  • [24] Cost-Effectiveness Analysis of an Advanced Hybrid Closed-Loop Insulin Delivery System in People with Type 1 Diabetes in Greece
    Lambadiari, Vaia
    Saltik, Asli Zeynep Ozdemir
    de Portu, Simona
    Buompensiere, Maria Ida
    Kountouri, Aikaterini
    Korakas, Emmanouil
    Sharland, Helen
    Cohen, Ohad
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (05) : 316 - 323
  • [25] Faster insulin action is associated with improved glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy in adults with type 1 diabetes
    Ruan, Yue
    Thabit, Hood
    Leelarathna, Lalantha
    Hartnell, Sara
    Wilinska, Malgorzata E.
    Tauschmann, Martin
    Dellweg, Sibylle
    Benesch, Carsten
    Mader, Julia K.
    Holzer, Manuel
    Kojzar, Harald
    Evans, Mark L.
    Pieber, Thomas R.
    Arnolds, Sabine
    Hovorka, Roman
    DIABETES OBESITY & METABOLISM, 2017, 19 (10) : 1485 - 1489
  • [26] Impact of the CamAPS FX hybrid closed-loop insulin delivery system on sleep traits in older adults with type 1 diabetes
    Thabit, Hood
    Boughton, Charlotte
    Mubita, Womba
    Rubio, Jose
    Mader, Julia K.
    Narendran, Parth
    Evans, Mark
    Leelarathna, Lalantha
    Wilinska, Malgorzata E.
    Fullwood, Catherine
    Gregory, Alice M.
    Hovorka, Roman
    Rutter, Martin K.
    DIABETES OBESITY & METABOLISM, 2023, 25 (03) : 889 - 893
  • [27] Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy
    Fuchs, Julia
    Hovorka, Roman
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (07) : 707 - 720
  • [28] Hybrid Closed-Loop System Achieves Optimal Perioperative Glycemia in a Boy With Type 1 Diabetes: A Case Report
    Dominguez-Riscart, Jesus
    Buero-Fernandez, Nuria
    Garcia-Zarzuela, Ana
    Marmolejo-Franco, Fernando A.
    Perez-Guerrero, Ana C.
    Lechuga-Sancho, Alfonso M.
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [29] Closed-Loop Insulin Delivery Effects on Glycemia During Sleep and Sleep Quality in Older Adults with Type 1 Diabetes: Results from the ORACL Trial
    Chakrabarti, Anindita
    Trawley, Steven
    Kubilay, Erin
    Alipoor, Andisheh Mohammad
    Vogrin, Sara
    Fourlanos, Spiros
    Lee, Melissa H.
    O'Neal, David N.
    O'Regan, Niamh A.
    Sundararajan, Vijaya
    Ward, Glenn M.
    MacIsaac, Richard J.
    Colman, Peter G.
    McAuley, Sybil A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (09) : 666 - 671
  • [30] Hybrid Closed-loop to Manage Gastroparesis in People With Type 1 Diabetes: a Case Series
    Daly, Aideen
    Hartnell, Sara
    Boughton, Charlotte K.
    Evans, Mark
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (06): : 1216 - 1223