Experimental and numerical analysis of the thermal performance of pebble solar thermal collector

被引:5
作者
Naik, N. Channa Keshava [1 ]
Priya, R. Krishna [2 ]
Agulut, Umit [3 ]
Gurel, Ali Etem [4 ]
Shaik, Saboor [5 ]
Alzaed, Ali Nasser [6 ]
Alwetaishi, Mamdooh [7 ]
Alahmadi, Ahmad Aziz [8 ]
机构
[1] Visvesvaraya Technol Univ, BGS Coll Engn & Technol, Dept Mech Engn, Bengaluru 560086, Karnataka, India
[2] Univ Technol & Appl Sci, Coll Engn & Technol, Engn Dept, Musandam, Oman
[3] Yildiz Tech Univ, Mech Engn Fac, Dept Mech Engn, TR-34349 Istanbul, Turkiye
[4] Duzce Univ, Duzce Vocat Sch, Dept Elect & Energy, TR-81010 Duzce, Turkiye
[5] Vellore Inst Technol, Sch Mech Engn, Vellore 632014, Tamil Nadu, India
[6] Taif Univ, Coll Engn, Dept Architecture Engn, Taif 21944, Saudi Arabia
[7] Taif Univ, Coll Engn, Dept Civil Engn, Taif 21944, Saudi Arabia
[8] Taif Univ, Coll Engn, Dept Elect Engn, Taif 21944, Saudi Arabia
关键词
Pebbles; Flat plate collector; Heat gain enhancement; Thermal efficiency; CFD; ABSORBER PLATE; AIR HEATER; WATER; ENERGY; STILL; STORAGE; SYSTEM; ROUNDNESS; EXERGY; DESIGN;
D O I
10.1016/j.heliyon.2024.e24218
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this work, pebbles of higher specific heat than the conventional absorber materials like aluminium or copper are proposed as a absorber in the solar flat plate collector. The proposed collector are integrated into the building design and constructed with masonry. Tests were conducted by varying the operating parameters which influence its performance, like the flow rate of the heat-absorbing medium, and the tilt of the collector using both coated and uncoated pebbles. The maximum temperature difference that could be measured for a conventional absorber was approximately 8 degrees C for a flow rate of 0.6 L/min. While for a coated and uncoated absorber, it was 7 degrees C and 5.5 degrees C respectively. This difference decreased with an increase in flow rates from 0.6 L/min to 1.2 L/min. For all the flow rates, it was observed that the average difference in efficiency between the coated and the conventional absorber collector is 5.82 %, while the difference between the coated and uncoated absorber collector is 15.68 %. Thus, it is very much evident that by replacing the conventional absorber with the proposed coated pebble absorber, the overall loss in efficiency is just 5.82 %, but the advantages are enormous. Along with the experimental study, numerical analysis was also carried out with CFD modeling. The numerical results agreed well with experimental results with the least error. Therefore, CFD simulation can be further used to optimize the design of the collector.
引用
收藏
页数:22
相关论文
共 50 条
[41]   Flat-Plate Solar Collector Thermal Performance and Optimal Operation Mode by Exergy Analysis and Numerical Simulation [J].
Yemeli Wenceslas Koholé ;
Fodoup Cyrille Vincelas Fohagui ;
Ghislain Tchuen .
Arabian Journal for Science and Engineering, 2021, 46 :1877-1897
[42]   Flat-Plate Solar Collector Thermal Performance and Optimal Operation Mode by Exergy Analysis and Numerical Simulation [J].
Kohole, Yemeli Wenceslas ;
Fohagui, Fodoup Cyrille Vincelas ;
Tchuen, Ghislain .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (02) :1877-1897
[43]   A Review of Experimental and Numerical Analyses of Solar Thermal Walls [J].
Sornek, Krzysztof ;
Papis-Fraczek, Karolina ;
Calise, Francesco ;
Cappiello, Francesco Liberato ;
Vicidomini, Maria .
ENERGIES, 2023, 16 (07)
[44]   Evacuated tube solar thermal collector with enhanced phase change material thermal storage: An experimental study [J].
Senobar, Hossein ;
Aramesh, Mohamad ;
Shabani, Bahman .
JOURNAL OF ENERGY STORAGE, 2022, 46
[45]   Experimental and numerical analysis of the collector roof height effect on the solar chimney performance [J].
Ayadi, Ahmed ;
Bouabidi, Abdallah ;
Driss, Zied ;
Abid, Mohamed Salah .
RENEWABLE ENERGY, 2018, 115 :649-662
[46]   An Experimental Performance on Solar Photovoltaic Thermal Collector with Nanofluids for Sustainable Development [J].
Gundala, Srinivasulu ;
Basha, M. Mahaboob ;
Madhurima, V ;
Praveena, N. ;
Kumar, S. Venkatesh .
JOURNAL OF NANOMATERIALS, 2021, 2021
[47]   Experimental study of solar photovoltaic/thermal (PV/T) air collector drying performance [J].
Kong, Decheng ;
Wang, Yunfeng ;
Li, Ming ;
Keovisar, Vanhkeo ;
Huang, Mengxiao ;
Yu, Qiongfen .
SOLAR ENERGY, 2020, 208 :978-989
[48]   Thermal Performance Enhancement in Flat Plate Solar Collector Solar Water Heater: A Review [J].
Azha, Nurril Ikmal Shamsul ;
Hussin, Hilmi ;
Nasif, Mohammad Shakir ;
Hussain, Tanweer .
PROCESSES, 2020, 8 (07)
[49]   Performance Analysis of a Two-way Hybrid Photovoltaic/Thermal Solar Collector [J].
Mortezapour, H. ;
Ghobadian, B. ;
Khoshtaghaza, M. H. ;
Minaei, S. .
JOURNAL OF AGRICULTURAL SCIENCE AND TECHNOLOGY, 2012, 14 (04) :767-780
[50]   Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector [J].
Daghigh, Roonak ;
Shafieian, Abdellah .