Effect of UV-C LED arrangement on the sterilization of Escherichia coli in planar water disinfection reactors

被引:5
作者
Wang, Chien-Ping [1 ]
Liao, Jun-You [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Mech Engn, Taipei, Taiwan
关键词
UV-C LED; Water disinfection; Hydrodynamics; UV fluence; COMPUTATIONAL FLUID-DYNAMICS; LIGHT-EMITTING-DIODES; PERFORMANCE; INACTIVATION; FLOW; OPTIMIZATION;
D O I
10.1016/j.jwpe.2023.104399
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a planar UV reactor with five distinct UV-C LED arrangements was proposed to treat drinking water. The particle tracing method combined with computational fluid dynamics were used to simulate water velocity field, microbial trajectory and residence time. The ray tracing method was used to determine the irradiance distribution in water. The simulated variables were then integrated to determine the distribution of fluence in water. Both experimental and theoretical results among the five distinct UV light modules used in this study, turn-enhanced emission exhibited the highest efficiency in sterilizing Escherichia coli owning to the synergic effect of hydrodynamics and UV radiation. Turn-enhanced emission combined with turn-induced secondary flow effectively improved the reactor performance. At a flow rate of 300 mL/min, turn-enhanced emission resulted in an inactivation value of 4.56 log, which was approximately 0.90, 0.82, 0.84, and 2.41 log higher than the values obtained with top, staggered, lined, and side emission, respectively. According to the particle count and cu-mulative count of the fluid particles, turn-enhanced emission effectively enhanced the UV fluence to which microbes in water were subjected. In conclusion, optimal combinations of LED arrangements and channel configurations effectively improve the sterilization efficiency of UV reactors.
引用
收藏
页数:9
相关论文
共 39 条
  • [1] Aral MM, 2017, J ENVIRON ENG, V143, DOI [10.1061/(ASCE)EE.1943-7870.0001266, 10.1061/(asce)ee.1943-7870.0001266]
  • [2] A study of enhanced performance of VUV/UV process for the degradation of micropollutants from contaminated water
    Bagheri, Mehdi
    Mohseni, Madjid
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2015, 294 : 1 - 8
  • [3] Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy
    Beck, Sara E.
    Ryu, Hodon
    Boczek, Laura A.
    Cashdollar, Jennifer L.
    Jeanis, Kaitlyn M.
    Rosenblum, James S.
    Lawal, Oliver R.
    Linden, Karl G.
    [J]. WATER RESEARCH, 2017, 109 : 207 - 216
  • [4] Multivariate optimization of fecal bioindicator inactivation by coupling UV-A and UV-C LEDs
    Chevremont, A. -C.
    Farnet, A. -M.
    Sergent, M.
    Coulomb, B.
    Boudenne, J. -L.
    [J]. DESALINATION, 2012, 285 : 219 - 225
  • [5] Cifuentes G., 2017, Chem. Eng. Trans, V57, P1291
  • [6] Influence of turn geometry on turbulent fluid flow and heat transfer in a stationary two-pass square duct
    Erelli, Ramesh
    Saha, Arun K.
    Panigrahi, P. K.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 667 - 684
  • [7] New water disinfection system using UVA light-emitting diodes
    Hamamoto, A.
    Mori, M.
    Takahashi, A.
    Nakano, M.
    Wakikawa, N.
    Akutagawa, M.
    Ikehara, T.
    Nakaya, Y.
    Kinouchi, Y.
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2007, 103 (06) : 2291 - 2298
  • [8] Inactivation credit of UV radiation for viruses, bacteria and protozoan (oo)cysts in water: A review
    Hijnen, WAM
    Beerendonk, EF
    Medema, GJ
    [J]. WATER RESEARCH, 2006, 40 (01) : 3 - 22
  • [9] Modeling a continuous flow ultraviolet Light Emitting Diode reactor using computational fluid dynamics
    Jenny, Richard M.
    Simmons, Otto D., III
    Shatalov, Max
    Ducoste, Joel J.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2014, 116 : 524 - 535
  • [10] Experimental and computational evaluation of a flow-through UV-LED reactor for MS2 and adenovirus inactivation
    Keshavarzfathy, Majid
    Hosoi, Yamato
    Oguma, Kumiko
    Taghipour, Fariborz
    [J]. CHEMICAL ENGINEERING JOURNAL, 2021, 407