Comparison of Manual (2D) and Digital (3D) Methods in the Assessment of Simulated Facial Edema

被引:4
作者
Dallazen, Eduardo [1 ]
Baccaro, Gabriela Cristina [1 ]
Santos, Anderson Maikon de Souza [1 ,5 ]
Queiroz, Mariana Elias [2 ]
Santiago Junior, Joel Ferreira [3 ]
Hochuli-Vieira, Eduardo
Faverani, Leonardo [1 ,4 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Dent, Dept Diag & Surg, Aracatuba, SP, Brazil
[2] Sao Paulo State Univ UNESP, Sch Dent, Dept Dent Mat & Prosthesis, Aracatuba, SP, Brazil
[3] Unisagrado, Sch Dent, Div Prosthesis, Bauru, SP, Brazil
[4] Araraquara Dent Sch, Dept Diag & Surg, Sao Paulo, Brazil
[5] Paraiba State Univ, Div Oral Surg, Araruna, Brazil
基金
巴西圣保罗研究基金会;
关键词
PRECISION; ACCURACY; LASER;
D O I
10.1016/j.joms.2023.05.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: An edema assessment following dental surgeries is essential to improving the dental surgeon ' s technique and, consequentially, patient comfort. Purpose: Two-dimensional (2D) methods are limited in analyzing 3-dimensional (3D) surfaces. Currently, 3D methods are used to investigate postoperative swelling. However, there are no studies that directly compare 2D and 3D methods. The goal of this study is to directly compare 2D and 3D methods used in the assessment of postoperative edema. Study design and sample: The investigators implemented a prospective, cross-sectional study with each subject serving as its own control. The sample was composed of dental student volunteers without facial deformities. Predictor variable: The predictor variable is the method used to measure edema. After simulating edema, manual (2D) and digital (3D) techniques were used to measure edema. The manual method used direct facial perimeter measurements. The two digital methods were photogrammetry using a smartphone (iPhone 11, Apple Inc, Cupertino, California), and facial scanning with a smartphone application (Bellus3D FaceApp, Bellus3D Inc, Campbell, California) [3D measurements] Main outcome variable: The coefficient of variation (CV) (CV = standard deviation /mean) was used to assess homogeneity of edema measurements. Analysis: The Shapiro-Wilk and equal variance tests were applied to assess data homogeneity. Next, one-way analysis of variance was performed, followed by a correlation analysis. Finally, the data were submitted to Tukey's test. The statistical significance threshold was set at 5% (P <.05). Results: The sample was composed of 20 subjects aged 18-38 years. The CV showed higher values using the manual (2D) method (47%; 4.88% +/- 2.99), compared with the photogrammetry method (18%; 8.55 mm +/- 1.52) and the smartphone application (21%; 8.97 mm +/- 1.93). A statistically significant difference was observed between the manual method values and those of the other two groups (P <.001). There was no difference between the facial scanning and photogrammetry groups (3D methods) (P =.778) Conclusion and Relevance: Both digital measuring methods (3D) demonstrated greater homogeneity than the manual method in analyzing facial distortions caused by the same swelling simulation. Therefore, it can be affirmed that digital methods may be more reliable that manual methods for assessing facial edema. (c) 2023 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1146 / 1154
页数:9
相关论文
共 50 条
  • [31] Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors
    Zhang, Dandan
    Wang, Bin
    Zhang, Guangshun
    Ma, Charlie
    Deng, Xiaowu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 230 - 238
  • [32] An in vitro comparison of subjective image quality of panoramic views acquired via 2D or 3D imaging
    Pittayapat, P.
    Galiti, D.
    Huang, Y.
    Dreesen, K.
    Schreurs, M.
    Couto Souza, P.
    Rubira-Bullen, I. R. F.
    Westphalen, F. H.
    Pauwels, R.
    Kalema, G.
    Willems, G.
    Jacobs, R.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 293 - 300
  • [33] Agreement between 2D and 3D radiographic outcome assessment one year after periapical surgery
    von Arx, T.
    Janner, S. F. M.
    Hanni, S.
    Bornstein, M. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 915 - 925
  • [34] Establishment and Comparison of Piecewise Linear Regression Models to Measure Thyroid Volume by 2D and 3D Ultrasound
    Wang, Yue-Gui
    Yang, Shu-Ping
    Cai, Ming-Yong
    Chen, Ke-Yue
    Li, Ting-Ting
    Shen, Hao-Lin
    CURRENT MEDICAL IMAGING, 2024, 20
  • [35] Shape optimization of 2D structures using simulated annealing
    Sonmez, Fazil O.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2007, 196 (35-36) : 3279 - 3299
  • [36] Optimization of plotting trajectory for precision 2D and 3D laser cutting
    Veiko, VP
    Yakovlev, AG
    Timofeev, BP
    Tretyakov, SA
    COMPUTER-CONTROLLED MICROSHAPING, 1999, 3822 : 184 - 191
  • [37] LEARNING 3D WHITE MATTER MICROSTRUCTURE FROM 2D HISTOLOGY
    Nath, Vishwesh
    Schilling, Kurt G.
    Remedios, Samuel
    Bayrak, Roza G.
    Gao, Yurui
    Blaber, Justin A.
    Huo, Yuankai
    Landman, Bennett A.
    Anderson, A. W.
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 186 - 190
  • [38] A Study on the Errors of 2D Circular Trajectories Generated on a 3D Printer
    Munteanu, Adriana
    Chitariu, Dragos-Florin
    Horodinca, Mihaita
    Dumitras, Catalin-Gabriel
    Negoescu, Florin
    Savin, Anatolie
    Chifan, Florin
    APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [39] Drawing Portraits and Still Lifes From 2D and 3D Sources
    Carson, Linda
    Siva, Parthipan
    Danckert, James
    PSYCHOLOGY OF AESTHETICS CREATIVITY AND THE ARTS, 2021, 15 (04) : 746 - 757
  • [40] Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures
    Hammerle, Diego
    Osterhoff, Georg
    Allemann, Florin
    Werner, Clement Max Leonard
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (03) : 557 - 563