Mini-implant mandibular overdentures under a two-step immediate loading protocol: A 4-6-year retrospective study

被引:7
作者
Park, Jin-Hong [1 ]
Shin, Sang-Wan [2 ]
Lee, Jeong-Yol [3 ,4 ]
机构
[1] Korea Univ Med, Korea Univ Guro Hosp, Dept Prosthodont, Seoul, South Korea
[2] Korea Univ Med, Seoul, South Korea
[3] Korea Univ, Grad Sch Clin Dent, Dept Adv Prosthodont, Seoul, South Korea
[4] Korea Univ, Dept Prosthodont, Guro Hosp, 148 Gurodong Ro, Seoul 08308, South Korea
关键词
dental implants; dentures; mandibular prosthesis; mini-implant; treatment outcome; QUALITY-OF-LIFE; PRIMARY STABILITY; DENTAL IMPLANTS; PATIENTS SATISFACTION; EDENTULOUS PATIENTS; DIAMETER IMPLANTS; COMPLETE DENTURES; SURVIVAL; SUCCESS;
D O I
10.1111/ger.12683
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This retrospective study to evaluate the treatment outcomes of mandibular mini--implant overdentures (MIODs) placed under a two--step immediate loading protocol. Background: The mini--implant overdenture emphasises the advantages of simplicity using flapless surgery and immediate loading. However, some mini--implant have lowe initial stability. Materials and Methods: A total of 30 participants who used mandibular MIODs and maxillary removable complete dentures (RCDs) over 4 years were included. Four one-piece mini--implants (<3 mm in diameter) were placed by a flapless surgical approach after fabrication of new RCDs, and the O--ring attachment was attached at least 8 weeks after implant placement. Results: The average observation period was 58.9 +/- 9.2 months after mini--implant loading. The survival rate of the implants was 100.0%, and the overall change in mean marginal bone level (Delta MBL) was -0.9 +/- 1.1 mm. The implant success rate was 83.3% at the implant level, and 66.7% at the patient level. The mean initial Periotest value was 0.9 +/- 3.1, and it was positively associated with Delta MBL and implant success (P <.05). Patient satisfaction improved after conversion from RCDs to MIODs (P <.05), and mastication and pain showed greater satisfaction with longer loading time (P <.05). Conclusions: The mandibular MIODs could be chosen as an alternative treatment under a two--step immediate--loading protocol in edentulous patients with limited alveolar bone volume. To ensure superior treatment outcomes of MIODs, initial stability of implant must be obtained using as wide a diameter as possible within the anatomically allowable limits.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 49 条
[1]   Relationship Between Implant Stability Measurements Obtained by Two Different Devices: A Systematic Review [J].
Andreotti, Agda Marobo ;
Goiato, Marcelo Coelho ;
Nobrega, Adhara Smith ;
Freitas da Silva, Emily Vivianne ;
Gennari Filho, Humberto ;
Pellizzer, Eduardo Piza ;
dos Santos, Daniela Micheline .
JOURNAL OF PERIODONTOLOGY, 2017, 88 (03) :281-288
[2]   Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability [J].
Arosio, Paolo ;
Greco, Gian Battista ;
Zaniol, Terry ;
Iezzi, Giovanna ;
Perrotti, Vittoria ;
Di Stefano, Danilo Alessio .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (02) :151-159
[3]   MINI IMPLANTS FOR DEFINITIVE PROSTHODONTIC TREATMENT: A SYSTEMATIC REVIEW [J].
Bidra, Avinash S. ;
Almas, Khalid .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (03) :156-164
[4]  
Branemark PI., 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[5]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[6]   The future of complete dentures in oral rehabilitation. A critical review [J].
Carlsson, G. E. ;
Omar, R. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (02) :143-156
[7]   Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study [J].
Degidi, Marco ;
Daprile, Giuseppe ;
Piattelli, Adriano .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :37-41
[8]   Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone [J].
Dilek, Ozkan ;
Tezulas, Emre ;
Dincel, Mert .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02) :E20-E27
[9]   Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque [J].
Duyck, Joke ;
Corpas, Livia ;
Vermeiren, Stephanie ;
Ogawa, Toru ;
Quirynen, Marc ;
Vandamme, Katleen ;
Jacobs, Reinhilde ;
Naert, Ignace .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) :877-884
[10]   Refusal of implant supported mandibular overdentures by elderly patients [J].
Ellis, Janice S. ;
Levine, Alissa ;
Bedos, Christophe ;
Mojon, Phillippe ;
Rosberger, Zeer ;
Feine, Jocelyne ;
Thomason, J. Mark .
GERODONTOLOGY, 2011, 28 (01) :62-68