In vitro study on the accuracy of sleeveless guided endodontics and treatment of a complex upper lateral incisor

被引:8
|
作者
Torres, A. [1 ,2 ]
Dierickx, M. [2 ]
Coucke, W.
Pedano, M. S. [2 ]
Lambrechts, P. [2 ]
Jacobs, R. [1 ,3 ,4 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci, Endodontol, Leuven, Belgium
[3] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[4] Univ Leuven, St Raphael Hosp, Fac Med, Dept Imaging & Pathol,OMFS IMPATH Res Grp, Kapucijnenvoer 7, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; BEAM COMPUTED-TOMOGRAPHY; CALCIFICATION; SYSTEM;
D O I
10.1016/j.jdent.2023.104466
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study aims to assess the accuracy of sleeveless guided endodontics for root canal treatment of severe pulp canal obliteration (PCO) in 3D printed jaws. Additionally, the treatment of a complex lateral incisor is presented to illustrate the use of sleeveless guides in a clinical situation. Methods: Two cone-beam computed tomography (CBCT) volumes of an upper and lower jaw were selected to design 3D printed models with PCO. Virtual planning of the access cavities was performed from right to left second premolar. Then, the models were mounted into a phantom head to simulate an actual patient. Two operators with different levels of experience in endodontics performed guided access cavities. The handpiece was guided by guiding rails placed against each other on the sides of the tooth. A post-operative CBCT scan was taken for analysis. Results: Eighty-eight guided access cavities (44 per operator) were drilled on eight 3D printed models. The mean length of the access cavities was 15.3 mm, with a mean coronal and apical deviation of 0.5 mm and 0.7 mm respectively. The mean angular deviation was 1.5 degrees. No statistically significant difference was found between operators for the three measured parameters. Conclusions: This study demonstrates, within its limitations, that sleveless guides represent an accurate method for guided endodontic treatment. No statistically significant difference between operators was found when using the guide. Clinical significance: This method offers a valuable alternative to conventional endodontic guides with similar accuracy results.
引用
收藏
页数:10
相关论文
共 39 条
  • [21] The accuracy of a novel image-guided hybrid robotic system for dental implant placement: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Lan, Kengliang
    Zhuang, Minjie
    Wang, Shigang
    Wang, Feng
    Chen, Xiaojun
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01)
  • [22] Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study
    Reiff, Florian Sebastian
    Bischoff, Charlotte
    Woelfler, Henriette
    Roehling, Stefan
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 28 (04): : 1491 - 1500
  • [23] Examining the Influence of Freehand, Pilot-Guided, and Fully Guided Surgical Protocols on the Accuracy of Immediately Placed Implants-An In Vitro Study
    Pitman, Jeremy
    Cosyn, Jan
    Christiaens, Veronique
    Younes, Faris
    De Bruyckere, Thomas
    Vervaeke, Stijn
    Glibert, Maarten
    APPLIED SCIENCES-BASEL, 2024, 14 (20):
  • [24] The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: An in vitro study
    Wang, Xiao-yu
    Liu, Lin
    Guan, Miao-sheng
    Liu, Qian
    Zhao, Tong
    Li, Hong-bo
    JOURNAL OF DENTISTRY, 2022, 124
  • [25] Evaluation of Three Different Validation Procedures regarding the Accuracy of Template-Guided Implant Placement: An In Vitro Study
    Vasak, Christoph
    Strbac, Georg D.
    Huber, Christian D.
    Lettner, Stefan
    Gahleitner, Andre
    Zechner, Werner
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 142 - 149
  • [26] Accuracy of a Template-Guided Implant Surgery System with a CAD/CAM-Based Measurement Method: An In Vitro Study
    Brandt, Jan
    Brenner, Martin
    Lauer, Hans-Christoph
    Brandt, Silvia
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 328 - 334
  • [27] Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study
    Adams, Coleman R.
    Ammoun, Rami
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 62 - 70
  • [28] Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study
    Kaya, Gozde
    Bilmenoglu, Caglar
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (06) : 388 - 398
  • [29] Evaluation of the Accuracy of Linear Measurements on Lateral Cephalograms Obtained From Cone-Beam Computed Tomography Scans With Digital Lateral Cephalometric Radiography: An In Vitro Study
    Shokri, Abbas
    Khajeh, Samira
    Khavid, Atefeh
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (05) : 1710 - 1713
  • [30] Does guided level (fully or partially) influence implant placement accuracy at post-extraction sockets and healed sites? An in vitro study
    Zhaozhao Chen
    Junying Li
    Priscila Ceolin Meneghetti
    Matthew Galli
    Gustavo Mendonça
    Hom-Lay Wang