In vitro study on the accuracy of sleeveless guided endodontics and treatment of a complex upper lateral incisor

被引:8
|
作者
Torres, A. [1 ,2 ]
Dierickx, M. [2 ]
Coucke, W.
Pedano, M. S. [2 ]
Lambrechts, P. [2 ]
Jacobs, R. [1 ,3 ,4 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci, Endodontol, Leuven, Belgium
[3] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[4] Univ Leuven, St Raphael Hosp, Fac Med, Dept Imaging & Pathol,OMFS IMPATH Res Grp, Kapucijnenvoer 7, B-3000 Leuven, Belgium
关键词
3-Dimensional printing; Accuracy; Cone beam computed tomography; Dental pulp calcification; Guided endodontics; ACCESS CAVITY PREPARATION; PULP CANAL OBLITERATION; BEAM COMPUTED-TOMOGRAPHY; CALCIFICATION; SYSTEM;
D O I
10.1016/j.jdent.2023.104466
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study aims to assess the accuracy of sleeveless guided endodontics for root canal treatment of severe pulp canal obliteration (PCO) in 3D printed jaws. Additionally, the treatment of a complex lateral incisor is presented to illustrate the use of sleeveless guides in a clinical situation. Methods: Two cone-beam computed tomography (CBCT) volumes of an upper and lower jaw were selected to design 3D printed models with PCO. Virtual planning of the access cavities was performed from right to left second premolar. Then, the models were mounted into a phantom head to simulate an actual patient. Two operators with different levels of experience in endodontics performed guided access cavities. The handpiece was guided by guiding rails placed against each other on the sides of the tooth. A post-operative CBCT scan was taken for analysis. Results: Eighty-eight guided access cavities (44 per operator) were drilled on eight 3D printed models. The mean length of the access cavities was 15.3 mm, with a mean coronal and apical deviation of 0.5 mm and 0.7 mm respectively. The mean angular deviation was 1.5 degrees. No statistically significant difference was found between operators for the three measured parameters. Conclusions: This study demonstrates, within its limitations, that sleveless guides represent an accurate method for guided endodontic treatment. No statistically significant difference between operators was found when using the guide. Clinical significance: This method offers a valuable alternative to conventional endodontic guides with similar accuracy results.
引用
收藏
页数:10
相关论文
共 39 条
  • [1] Guided Endodontics: Use of a Sleeveless Guide System on an Upper Premolar with Pulp Canal Obliteration and Apical Periodontitis
    Torres, Andres
    Lerut, Kathleen
    Lambrechts, Paul
    Jacobs, Reinhilde
    JOURNAL OF ENDODONTICS, 2021, 47 (01) : 133 - 139
  • [2] Guided endodontics: a comparative in vitro study on the accuracy and effort of two different planning workflows
    Krug, Ralf
    Reich, Sebastian
    Connert, Thomas
    Kess, Stefan
    Soliman, Sebastian
    Reymus, Marcel
    Krastl, Gabriel
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2020, 23 (02) : 119 - 128
  • [3] The accuracy of using guided endodontics in access cavity preparation and the temperature changes of root surface: An in vitro study
    Zhang, Cuifeng
    Zhao, Xiao
    Chen, Cheng
    Wang, Jingyan
    Gu, Peiyu
    Ma, Junchi
    Wu, Daming
    Li, Jin
    BMC ORAL HEALTH, 2022, 22 (01)
  • [4] Guided endodontics: accuracy of access cavity preparation and discrimination of angular and linear deviation on canal accessing ability-an ex vivo study
    Su, Yinghui
    Chen, Chenghui
    Lin, Chiahua
    Lee, Huina
    Chen, Kerkong
    Lin, Yenkun
    Fuhsiung Chuang
    BMC ORAL HEALTH, 2021, 21 (01)
  • [5] Novel method for augmented reality guided endodontics: An in vitro study
    Farronato, Marco
    Torres, Andres
    Pedano, Mariano S.
    Jacobs, Reinhilde
    JOURNAL OF DENTISTRY, 2023, 132
  • [6] The accuracy of using guided endodontics in access cavity preparation and the temperature changes of root surface: An in vitro study
    Cuifeng Zhang
    Xiao Zhao
    Cheng Chen
    Jingyan Wang
    Peiyu Gu
    Junchi Ma
    Daming Wu
    Jin Li
    BMC Oral Health, 22
  • [7] Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling Accuracy in Guided Endodontics: An In-Vitro Study
    Henaut, Marine
    Meire, Maarten
    Vandomme, Jerome
    Robberecht, Lieven
    EUROPEAN ENDODONTIC JOURNAL, 2025, 10 (02): : 127 - 133
  • [8] Dynamic navigation: a laboratory study on the accuracy and potential use of guided root canal treatment
    Torres, Andres
    Boelen, Gerd-Jan
    Lambrechts, Paul
    Pedano, Mariano Simon
    Jacobs, Reinhilde
    INTERNATIONAL ENDODONTIC JOURNAL, 2021, 54 (09) : 1659 - 1667
  • [9] Guided endodontics: accuracy of access cavity preparation and discrimination of angular and linear deviation on canal accessing ability—an ex vivo study
    Yinghui Su
    Chenghui Chen
    Chiahua Lin
    Huina Lee
    Kerkong Chen
    Yenkun Lin
    Fuhsiung Chuang
    BMC Oral Health, 21
  • [10] Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study
    Yi, Chun
    Li, Sha
    Wen, Aonan
    Wang, Yong
    Zhao, Yijiao
    Zhang, Yu
    BMC ORAL HEALTH, 2022, 22 (01)