Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation

被引:5
|
作者
Hochreiter, Bettina [1 ]
Meisterhans, Michel [1 ]
Zindel, Christoph [1 ]
Calek, Anna-Katharina [1 ]
Gerber, Christian [1 ,2 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Orthopaed Res Ctr, Balgrist Campus, Zurich, Switzerland
关键词
Reverse total shoulder arthroplasty; RTSA; Internal rotation; Extension; Neck shaft angle; Baseplate; Orientation; Position; NECK-SHAFT ANGLE; GLENOID LATERALIZATION; PROXIMAL HUMERUS; MOTION; RANGE; DESIGN; RETROVERSION; INCLINATION; PROSTHESIS; POSITION;
D O I
10.1186/s40634-023-00580-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeFunctional internal rotation (IR) is a combination of extension and IR. It is clinically often limited after reverse total shoulder arthroplasty (RTSA) either due to loss of extension or IR in extension. It was the purpose of this study to determine the ideal in-vitro combination of glenoid and humeral components to achieve impingement-free functional IR.MethodsRTSA components were virtually implanted into a normal scapula (previously established with a statistical shape model) and into a corresponding humerus using a computer planning program (CASPA). Baseline glenoid configuration consisted of a 28 mm baseplate placed flush with the posteroinferior glenoid rim, a baseplate inclination angle of 96 degrees (relative to the supraspinatus fossa) and a 36 mm standard glenosphere. Baseline humeral configuration consisted of a 12 mm humeral stem, a metaphysis with a neck shaft angle (NSA) of 155 degrees (+ 6 mm medial offset), anatomic torsion of -20 degrees and a symmetric PE inlay (36mmx0mm). Additional configurations with different humeral torsion (-20 degrees, + 10 degrees), NSA (135 degrees, 145 degrees, 155 degrees), baseplate position, diameter, lateralization and inclination were tested. Glenohumeral extension of 5, 10, 20, and 40 degrees was performed first, followed by IR of 20, 40, and 60 degrees with the arm in extension of 40 degrees-the value previously identified as necessary for satisfactory clinical functional IR. The different component combinations were taken through simulated ROM and the impingement volume (mm(3)) was recorded. Furthermore, the occurrence of impingement was read out in 5 degrees motion increments.ResultsIn all cases where impingement occurred, it occurred between the PE inlay and the posterior glenoid rim. Only in 11 of 36 combinations full functional IR was possible without impingement. Anterosuperior baseplate positioning showed the highest impingement volume with every combination of NSA and torsion. A posteroinferiorly positioned 26 mm baseplate resulting in an additional 2 mm of inferior overhang as well as 6 mm baseplate lateralization offered the best impingement-free functional IR (5/6 combinations without impingement). Low impingement potential resulted from a combination of NSA 135 degrees and + 10 degrees torsion (4/6 combinations without impingement), followed by NSA 135 degrees and -20 degrees torsion (3/6 combinations without impingement) regardless of glenoid setup.ConclusionThe largest impingement-free functional IRs resulted from combining a posteroinferior baseplate position, a greater inferior glenosphere overhang, 90 degrees of baseplate inclination angle, 6 mm glenosphere lateralization with respect to baseline setup, a lower NSA and antetorsion of the humeral component. Surgeons can employ and combine these implant configurations to achieve and improve functional IR when planning and performing RTSA.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The effect of body mass index on internal rotation and function following anatomic and reverse total shoulder arthroplasty
    Eichinger, Josef K.
    Rao, Meghana V.
    Lin, Jackie J.
    Goodloe, Jonathan B.
    Kothandaraman, Venkatraman
    Barfield, William R.
    Parada, Stephen A.
    Roche, Christopher
    Friedman, Richard J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (02) : 265 - 272
  • [32] A pilot-study focusing on internal rotation after reverse total shoulder arthroplasty using the Activities of Daily Living which require Internal Rotation (ADLIR) score
    Beckers, Joris J.
    Lafosse, Laurent
    Caruso, Giovanni
    Kopel, Luc
    Commeil, Paul
    Mariaux, Sandrine
    Lafosse, Thibault
    SHOULDER & ELBOW, 2022, 14 (06) : 657 - 662
  • [33] Implant impingement during internal rotation after reverse shoulder arthroplasty. The effect of implant configuration and scapula anatomy: A biomechanical study
    Kraemer, Manuel
    Baeunker, Alexandra
    Wellmann, Mathias
    Hurschler, Christof
    Smith, Tomas
    CLINICAL BIOMECHANICS, 2016, 33 : 111 - 116
  • [34] Functional improvements in active elevation, external rotation, and internal rotation after reverse total shoulder arthroplasty with isolated latissimus dorsi transfer: surgical technique and midterm follow-up
    Popescu, Ion-Andrei
    Bihel, Thomas
    Henderson, Daniel
    Becerra, Javier Martin
    Agneskirchner, Jens
    Lafosse, Laurent
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (12) : 2356 - 2363
  • [35] Failure after reverse total shoulder arthroplasty: what is the success of component revision?
    Black, Eric M.
    Roberts, Susanne M.
    Siegel, Elana
    Yannopoulos, Paul
    Higgins, Laurence D.
    Warner, Jon J. P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (12) : 1908 - 1914
  • [36] Preoperative external rotation deficit does not predict poor outcomes or lack of improvement after reverse total shoulder arthroplasty
    Parsons, Moby
    Routman, Howard D.
    Roche, Christopher P.
    Friedman, Richard J.
    JOURNAL OF ORTHOPAEDICS, 2020, 21 : 379 - 383
  • [37] Impact of humeral and glenoid component variations on range of motion in reverse geometry total shoulder arthroplasty: a standardized computer model study
    Arenas-Miquelez, Antonio
    Murphy, Richard J.
    Rosa, Andrea
    Caironi, Davide
    Zumstein, Matthias A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (04) : 763 - 771
  • [38] Analysis of in vivo humeral rotation of reverse total shoulder arthroplasty patients during shoulder abduction on the scapular plane with a load
    Takahashi, Yuji
    Nishinaka, Naoya
    Furuya, Kanji
    Ikeda, Takashi
    Jinno, Tetsuya
    Okawa, Atsushi
    Sakai, Tomoko
    ARTHROPLASTY, 2023, 5 (01)
  • [39] Adjusting Implant Size and Position Can Improve Internal Rotation After Reverse Total Shoulder Arthroplasty in a Three-dimensional Computational Model
    Huish, Eric G., Jr.
    Athwal, George S.
    Neyton, Lionel
    Walch, Gilles
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 198 - 204
  • [40] Sports after shoulder arthroplasty: a comparative analysis of hemiarthroplasty and reverse total shoulder replacement
    Liu, Joseph N.
    Garcia, Grant H.
    Mahony, Gregory
    Wu, Hao-Hua
    Dines, David M.
    Warren, Russell F.
    Gulotta, Lawrence V.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 920 - 926