Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty

被引:5
作者
Riechelmann, Felix [1 ]
Lettner, H. [2 ]
Mayr, R. [1 ]
Tandogan, R. [3 ,4 ]
Dammerer, D. [5 ]
Liebensteiner, M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Orthopaed & Traumatol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Anichstr 35, A-6020 Innsbruck, Austria
[3] Ortoklinik, Ankara, Turkiye
[4] Halic Univ, Dept Orthopaed & Traumatol, Istanbul, Turkiye
[5] Univ Hosp Krems, Krems, Austria
关键词
Total knee arthroplasty; Digital templating; Accuracy; EndoCert; Operative time; Storage cost; REPLACEMENT;
D O I
10.1007/s00402-023-04772-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.).Materials and methodsThe study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of +/- one size (at the femur or tibia or both) was classified "accurate." A deviation of +/- two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis.ResultsA total of 482 cases [33.6% male, 66.4% female, age 69 +/- 11, body mass index (BMI) 30.3 +/- 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.ConclusionsThe accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods.
引用
收藏
页码:4705 / 4711
页数:7
相关论文
共 50 条
  • [31] Preoperative predictors of implant size in patients undergoing total knee arthroplasty: a retrospective cohort study
    Mohsen Ostovar
    Mahmoud Jabalameli
    Mohammad Reza Bahaeddini
    Abolfazl Bagherifard
    Mansour Bahardoust
    Alireza Askari
    BMC Musculoskeletal Disorders, 24
  • [32] Preoperative predictors of implant size in patients undergoing total knee arthroplasty: a retrospective cohort study
    Ostovar, Mohsen
    Jabalameli, Mahmoud
    Bahaeddini, Mohammad Reza
    Bagherifard, Abolfazl
    Bahardoust, Mansour
    Askari, Alireza
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [33] Demographic data is more predictive of component size than digital radiographic templating in total knee arthroplasty
    Stephen J. Wallace
    Michael P. Murphy
    Corey J. Schiffman
    William J. Hopkinson
    Nicholas M. Brown
    Knee Surgery & Related Research, 32
  • [34] A deep learning based automatic two-dimensional digital templating model for total knee arthroplasty
    Park, Jaeseok
    Kim, Sung Eun
    Kim, Back
    Lee, Sanggyu
    Lee, Jae-Jun
    Ro, Du Hyun
    KNEE SURGERY & RELATED RESEARCH, 2024, 36 (01)
  • [35] Development of Preoperative Prediction Models for Pain and Functional Outcome After Total Knee Arthroplasty Using The Dutch Arthroplasty Register Data
    Tolk, Jaap J.
    Waarsing, J. H.
    Janssen, Rob P. A.
    van Steenbergen, Liza N.
    Bierma-Zeinstra, Sita M. A.
    Reijman, Max
    JOURNAL OF ARTHROPLASTY, 2020, 35 (03) : 690 - +
  • [36] Prediction of postoperative pain by preoperative pain response to heat stimulation in total knee arthroplasty
    Lunn, Troels H.
    Gaarn-Larsen, Lissi
    Kehlet, Henrik
    PAIN, 2013, 154 (09) : 1878 - 1885
  • [37] Preoperative Templating for Total Hip Arthroplasty: A Method for Calibrating Digital Radiographs Using Patient Demographics and Anthropometric Measurements
    Attwood, Joseph
    Banks, Philippa
    Sidhom, Adam
    Pandit, Hemant
    Sidhom, Sameh
    van Duren, Bernard
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [38] Preoperative haemoglobin cut-off values for the prediction of post-operative transfusion in total knee arthroplasty
    Yeh, Jared Ze Yang
    Chen, Jerry Yongqiang
    Bin Abd Razak, Hamid Rahmatullah
    Loh, Bryan Huai Gu
    Hao, Ying
    Yew, Andy Khye Soon
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (10) : 3293 - 3298
  • [39] Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty
    Jaehyun Kim
    Seongyun Park
    Ji Hyun Ahn
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2065 - 2074
  • [40] Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty
    Kim, Jaehyun
    Park, Seongyun
    Ahn, Ji Hyun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (08) : 2065 - 2074