Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty

被引:5
作者
Riechelmann, Felix [1 ]
Lettner, H. [2 ]
Mayr, R. [1 ]
Tandogan, R. [3 ,4 ]
Dammerer, D. [5 ]
Liebensteiner, M. [1 ]
机构
[1] Med Univ Innsbruck, Dept Orthopaed & Traumatol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Anichstr 35, A-6020 Innsbruck, Austria
[3] Ortoklinik, Ankara, Turkiye
[4] Halic Univ, Dept Orthopaed & Traumatol, Istanbul, Turkiye
[5] Univ Hosp Krems, Krems, Austria
关键词
Total knee arthroplasty; Digital templating; Accuracy; EndoCert; Operative time; Storage cost; REPLACEMENT;
D O I
10.1007/s00402-023-04772-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.).Materials and methodsThe study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of +/- one size (at the femur or tibia or both) was classified "accurate." A deviation of +/- two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis.ResultsA total of 482 cases [33.6% male, 66.4% female, age 69 +/- 11, body mass index (BMI) 30.3 +/- 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.ConclusionsThe accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods.
引用
收藏
页码:4705 / 4711
页数:7
相关论文
共 50 条
  • [1] Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
    Felix Riechelmann
    H. Lettner
    R. Mayr
    R. Tandogan
    D. Dammerer
    M. Liebensteiner
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4705 - 4711
  • [2] Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty
    Kobayashi, Atsushi
    Ishii, Yoshinori
    Takeda, Mitsuhiro
    Noguchi, Hideo
    Higuchi, Hiroshi
    Toyabe, Sinichi
    COMPUTER AIDED SURGERY, 2012, 17 (02) : 96 - 101
  • [3] The accuracy of preoperative implant size prediction achieved by digital templating in total knee arthroplasty is not affected by the quality of lateral knee radiographs
    Pichler, Lorenz
    Klein, Leonhard
    Perka, Carsten F.
    Gwinner, Clemens
    El Kayali, Moses K. D.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    KNEE, 2016, 23 (01) : 149 - 151
  • [5] Algorithm based automatic templating is less accurate than manual digital templating in total knee arthroplasty
    Seaver, Thomas
    McAlpine, Kenneth
    Garcia, Enrique
    Niu, Ruijia
    Smith, Eric L.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (07) : 1472 - 1476
  • [6] Preoperative Templating and Computer-Assisted Total Knee Arthroplasty for Arthritic Valgus Knee
    Chou, Wen-Yi
    Siu, Ka-Kit
    Ko, Jih-Yang
    Chen, Jung-Ming
    Wang, Ching-Jen
    Wang, Feng-Sheng
    Wong, To
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10) : 1781 - 1787
  • [7] Precision of preoperative digital templating in total hip arthroplasty
    Efe, Turgay
    El Zayat, Bilal Farouk
    Heyse, Thomas J.
    Timmesfeld, Nina
    Fuchs-Winkelmann, Susanne
    Schmitt, Jan
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 616 - 621
  • [8] The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
    Smith, Joshua B. V.
    Bishi, Habeeb
    Wang, Chao
    Asopa, Vipin
    Field, Richard E.
    Sochart, David H.
    EFORT OPEN REVIEWS, 2021, 6 (11) : 1020 - 1039
  • [9] Preoperative CT-Based Three-Dimensional Templating in Robot-Assisted Total Knee Arthroplasty More Accurately Predicts Implant Sizes than Two-Dimensional Templating
    Pietrzak, J. R. T.
    Rowan, F. E.
    Kayani, B.
    Donaldson, M. J.
    Huq, S. S.
    Haddad, F. S.
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 642 - 648
  • [10] Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty
    Hernandez-Vaquero, Daniel
    Abat, Ferran
    Sarasquete, Juan
    Carlos Monllau, Juan
    WORLD JOURNAL OF ORTHOPEDICS, 2013, 4 (04): : 287 - 290