Thermal-hydraulic performance of printed circuit heat exchangers with various channel shapes under rolling conditions

被引:3
|
作者
Yang, Xian [1 ]
Zhang, Zenghui [1 ]
Tian, Ke [2 ]
Wang, Jin [1 ]
Ma, Ting [2 ]
Sunden, Bengt [3 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Thermo Fluid Sci & Engn, MOE, Xian 710049, Peoples R China
[3] Lund Univ, SE-22100 Lund, Sweden
基金
中国国家自然科学基金;
关键词
Liquefied natural gas; Printed circuit heat exchanger; Zigzag channel; Rolling condition; Heat transfer enhancement; NATURAL-GAS LIQUEFACTION; ZIGZAG CHANNEL; PRESSURE-DROP; FLOW; STRAIGHT; CIRCULATION; PARAMETERS; DESIGN; FINS;
D O I
10.1016/j.applthermaleng.2024.122779
中图分类号
O414.1 [热力学];
学科分类号
摘要
The floating liquefied natural gas (LNG) facilities are located in deep oceans, where the harsh ocean conditions cause the facilities to sway and tilt. The rolling conditions in floating LNG systems affect the uniformity of gas-liquid distribution in heat exchangers. Thermal and hydraulic performances of printed circuit heat exchangers (PCHEs) with straight, zigzag, and trapezoidal channels are investigated under static and rolling conditions. The results reveal that all channels enhance heat transfer near the pseudo-critical point of LNG at a rolling period of 2 s and a rolling amplitude of 15 degrees. The Nusselt number for the PCHE with a zigzag channel increases by 32.2% and 72.5% compared to those with straight and trapezoidal channels. The highest increase in comprehensive performance is obtained for the zigzag channel with an evaluation index of 1.23 under the rolling condition. Compared with under the static condition, the Nusselt number and Fanning friction factor for the zigzag channel increase by 12% and 28% under the rolling condition. The thermal performance is weakened by the nonuniform flow velocity and improved by the enhancement of flow turbulence. The thermal-hydraulic performance increases with the rolling period from 1 s to 3 s and the rolling amplitude from 15 degrees to 45 degrees. The maximum improvement of 65.3% and 97.2% in Nusselt number and Fanning friction factors is observed at a rolling period of 1 s and a rolling amplitude of 45 degrees. The methods to suppress the deterioration of heat transfer in microfluidic channels under rolling conditions are proposed to satisfy the requirement of LNG with low-resistance and high-efficiency microfluidic structure.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Printed circuit heat exchanger thermal-hydraulic performance in supercritical CO2 experimental loop
    Nikitin, Konstantin
    Kato, Yasuyoshi
    Ngo, Lam
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (05): : 807 - 814
  • [42] Experimental and numerical study on thermal-hydraulic performance of printed circuit heat exchanger for liquefied gas vaporization
    Zhao, Zhongchao
    Chen, Xudong
    Zhang, Xiao
    Ma, Xiaolong
    Yang, Shan
    ENERGY SCIENCE & ENGINEERING, 2020, 8 (02) : 426 - 440
  • [43] Numerical study of thermal-hydraulic performance of sCO2-molten salt printed circuit heat exchanger with discontinuous fins channel
    Yang, Yanchun
    Lu, Yuanwei
    Wei, Haijiao
    Wu, Yuting
    Gao, Qi
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 84 (03) : 198 - 218
  • [44] Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review
    Xiong, Tong
    Liu, Guoqiang
    Gao, Qiang
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF BUILDING ENGINEERING, 2023, 64
  • [45] A review on improving thermal-hydraulic performance of fin-and-tube heat exchangers
    Nickolas, N.
    Moorthy, P.
    Oumer, A. N.
    Ishak, M.
    4TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING RESEARCH (ICMER2017), 2017, 257
  • [46] Enhanced thermal-hydraulic performance in tubes of reciprocating scraped surface heat exchangers
    Solano, J. P.
    Martinez, D. S.
    Vicente, P. G.
    Viedma, A.
    APPLIED THERMAL ENGINEERING, 2023, 220
  • [47] Thermal-hydraulic performance of small scale micro-channel and porous-media heat-exchangers
    Jiang, PX
    Fan, MH
    Si, GS
    Ren, ZP
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (05) : 1039 - 1051
  • [48] THERMAL AND HYDRAULIC PERFORMANCE OF HEAT-EXCHANGERS UNDER CONDITIONS OF CHANGING FLOW REGIME
    ELKANZI, EM
    SAID, A
    INDIAN JOURNAL OF TECHNOLOGY, 1988, 26 (09): : 411 - 415
  • [49] Thermal-hydraulic performance enhancement of fin-and-tube heat exchangers using carbon nanotube coatings under dry and wet conditions
    Seok, Heuijun
    Han, Changho
    Lee, Dongchan
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2023, 231
  • [50] The thermal-hydraulic characteristics of staggered circular finned-tube heat exchangers under dry and dehumidifying conditions
    Jang, JY
    Lai, JT
    Liu, LC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (21) : 3321 - 3337