Soft Magnetic-Actuation-Based Haptic Interface for a Robot-Assisted Vascular Interventional System: A Feasibility Study

被引:4
作者
Li, Xinming [1 ]
Guo, Shuxiang [2 ,3 ,4 ]
Suzuki, Keisuke [1 ]
Shi, Peng [1 ]
Jin, Xiaoliang [1 ]
机构
[1] Kagawa Univ, Grad Sch Engn, Takamatsu, Kagawa 7610396, Japan
[2] Southern Univ Sci & Technol, Dept Elect & Elect Engn, Shenzhen 518055, Peoples R China
[3] Beijing Inst Technol, Sch Life Sci, Beijing 100081, Peoples R China
[4] Beijing Inst Technol, Minist Ind & Informat Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Beijing 100081, Peoples R China
基金
日本学术振兴会;
关键词
Haptic interfaces; Robot sensing systems; Robots; Sensors; Surgery; Safety; Manipulators; Haptic sensing; robot-assisted vascular interventional system (VIS); safety operation strategy; soft magnetic-actuation-based haptic interface; GUIDEWIRE;
D O I
10.1109/JSEN.2023.3332041
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a promising alternative for minimally invasive vascular surgery, robot-assisted vascular interventional system (VIS) has expressed considerable benefits in preventing radiation, decreasing workload for surgeons, improving surgical environment, and reducing postoperative risk for patients. However, the existing robotic VISs ignore to employ proper haptic feedback for robot-assisted surgery owing to the short of flexible and controllable capabilities of haptic perception. In this work, we develop a dual-instrument operating robotic VIS to manipulate guidewire and catheter, which is capable for multi-instrument surgical tasks. Most importantly, a soft magnetic-actuation-based haptic interface, a prospective solution for haptic sensing based on flexible combination of soft material and magnetic material, is proposed to provide adjustable haptic information for operators. Moreover, a safety operation strategy based on the proposed haptic interface is designed to ensure a safer operating environment for interaction between master side and slave side. Four kinds of experiments are performed to demonstrate the feasibility of soft magnetic-actuation-based haptic feedback and evaluate the tracking performance and operating performance of developed robot-assisted VIS. Results prove the engineering feasibility (haptic sensing range: 0.01-1.49 N) of the proposed haptic interface and the operating effectiveness of developed robot-assisted VIS (maximum linear error is 1.87 mm). Besides, this effort probably has a potential impact on the implementation of soft haptic feedback, research of multi-instrument device, and improvement of safety operation for robotic systems.
引用
收藏
页码:710 / 721
页数:12
相关论文
共 28 条
  • [1] Abdelaziz MEMK, 2019, IEEE INT C INT ROBOT, P5411, DOI [10.1109/IROS40897.2019.8968237, 10.1109/iros40897.2019.8968237]
  • [2] Multilevel Operation Strategy of a Vascular Interventional Robot System for Surgical Safety in Teleoperation
    Bao, Xianqiang
    Guo, Shuxiang
    Guo, Yangming
    Yang, Cheng
    Shi, Liwei
    Li, Youxiang
    Jiang, Yuhua
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2022, 38 (04) : 2238 - 2250
  • [3] Operation evaluation in-human of a novel remote-controlled vascular interventional robot
    Bao, Xianqiang
    Guo, Shuxiang
    Xiao, Nan
    Li, Youxiang
    Yang, Cheng
    Shen, Rui
    Cui, Jinxin
    Jiang, Yuhua
    Liu, Xinke
    Liu, Keyun
    [J]. BIOMEDICAL MICRODEVICES, 2018, 20 (02)
  • [4] A cooperation of catheters and guidewires-based novel remote-controlled vascular interventional robot
    Bao, Xianqiang
    Guo, Shuxiang
    Xiao, Nan
    Li, Youxiang
    Yang, Cheng
    Jiang, Yuhua
    [J]. BIOMEDICAL MICRODEVICES, 2018, 20 (01)
  • [5] Novel, Flexible, and Ultrathin Pressure Feedback Sensor for Miniaturized Intraventricular Neurosurgery Robotic Tools
    Chen, Tianhao
    Saadatnia, Zia
    Kim, Jongwoo
    Looi, Thomas
    Drake, James
    Diller, Eric
    Naguib, Hani E.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (05) : 4415 - 4425
  • [6] Chi WQ, 2020, IEEE INT CONF ROBOT, P2414, DOI [10.1109/icra40945.2020.9196912, 10.1109/ICRA40945.2020.9196912]
  • [7] Dagnino G, 2018, IEEE INT C INT ROBOT, P1770, DOI 10.1109/IROS.2018.8593628
  • [8] A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force Feedback
    Guo, Shuxiang
    Song, Yu
    Yin, Xuanchun
    Zhang, Linshuai
    Tamiya, Takashi
    Hirata, Hideyuki
    Ishihara, Hidenori
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2019, 35 (03) : 685 - 696
  • [9] Integral-Free Spatial Orientation Estimation Method and Wearable Rotation Measurement Device for Robot-Assisted Catheter Intervention
    Hooshiar, Amir
    Sayadi, Amir
    Dargahi, Javad
    Najarian, Siamak
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2022, 27 (02) : 766 - 776
  • [10] Active Suppression Method of Dangerous Behaviors for Robot-Assisted Vascular Interventional Surgery
    Jin, Xiaoliang
    Guo, Shuxiang
    Guo, Jian
    Shi, Peng
    Kawanishi, Masahiko
    Hirata, Hideyuki
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71