Sub-aperture ultrafast volumetric ultrasound imaging for fully sampled dual-mode matrix array

被引:0
作者
Qiang, Yu [1 ,2 ,3 ]
Wang, Xingying [1 ,2 ,3 ]
Liu, Rong [1 ,2 ]
Han, Xuan [1 ,2 ]
Zheng, Hairong [1 ,2 ,3 ]
Qiu, Weibao [1 ,2 ,3 ]
Zhang, Zhiqiang [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen 518055, Peoples R China
[2] Shenzhen Key Lab Ultrasound Imaging & Therapy, Shenzhen 518055, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
基金
国家重点研发计划; 美国国家科学基金会;
关键词
Volumetric ultrasound imaging; Sub-aperture imaging; Dual-mode matrix array; Imaging guidance; INTENSITY FOCUSED ULTRASOUND;
D O I
10.1016/j.ultras.2023.107172
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Fully sampled dual-mode matrix array ultrasound transducer is capable of performing imaging and therapeutic ultrasound in three dimensions (3D). It is a promising tool for many clinical applications because of its precise multi-focus therapy with imaging guidance by itself. Our team previously designed a 256-element fully sampled dual-mode matrix array transducer, while its imaging quality needs to be further improved. In this work, we propose a high-contrast sub-aperture volumetric imaging strategy to improve the imaging quality of the dual mode matrix array. We first analyzed the effect of various parameters of sub-aperture imaging on the imaging quality by Field II. Based on the optimized parameters, we compared the resolution and signal to noise ratio (SNR) of sub-aperture imaging with those of full aperture imaging on phantoms and rabbit brain. The experimental results showed the proposed sub-aperture imaging method could obtain a comparable resolution to full aperture imaging. Moreover, the average intensity of noise signal near the wire phantom decreased by about 5 dB and the SNR of tissue phantom image increased by 8 %. The proposed sub-aperture imaging method also enabled clearer and more accurate imaging of the rabbit brain. The obtained results indicate the proposed sub-aperture imaging is a promising method for practical use of a fully sampled dual-mode matrix array for volumetric ultrasound imaging.
引用
收藏
页数:7
相关论文
共 38 条
  • [1] Adaptive Transthoracic Refocusing of Dual-Mode Ultrasound Arrays
    Ballard, John R.
    Casper, Andrew J.
    Wan, Yayun
    Ebbini, Emad S.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 93 - 102
  • [2] High-frame-rate volume imaging using sparse-random-aperture compounding
    Bernal, Miguel
    Cunitz, Bryan
    Rohrbach, Daniel
    Daigle, Ron
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
  • [3] Whole-Brain 3D Activation and Functional Connectivity Mapping in Mice using Transcranial Functional Ultrasound Imaging
    Bertolo, Adrien
    Nouhoum, Mohamed
    Cazzanelli, Silvia
    Ferrier, Jeremy
    Mariani, Jean-Charles
    Kliewer, Andrea
    Belliard, Benoit
    Osmanski, Bruno-Felix
    Deffieux, Thomas
    Pezet, Sophie
    Lenkei, Zsolt
    Tanter, Mickael
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (168):
  • [4] Imaging Performance for Two Row-Column Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Nikolov, Svetoslav Ivanov
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) : 1209 - 1221
  • [5] Real-time Implementation of a Dual-Mode Ultrasound Array System: In Vivo Results
    Casper, Andrew
    Haritonova, Alyona
    Liu, Dalong
    Ballard, John
    Ebbini, Emad
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2164 - 2167
  • [6] An image-guided high intensity focused ultrasound device for uterine fibroids treatment
    Chan, AH
    Fujimoto, VY
    Moore, DE
    Martin, RW
    Vaezy, S
    [J]. MEDICAL PHYSICS, 2002, 29 (11) : 2611 - 2620
  • [7] Couade M., 2009, 2009 IEEE INT ULTR S
  • [8] Focused Ultrasound for Neuromodulation
    Darrow, David P.
    [J]. NEUROTHERAPEUTICS, 2019, 16 (01) : 88 - 99
  • [9] 2-DIMENSIONAL RANDOM ARRAYS FOR REAL-TIME VOLUMETRIC IMAGING
    DAVIDSEN, RE
    JENSEN, JA
    SMITH, SW
    [J]. ULTRASONIC IMAGING, 1994, 16 (03) : 143 - 163
  • [10] Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications
    Fomenko, Anton
    Neudorfer, Clemens
    Dallapiazza, Robert F.
    Kalia, Suneil K.
    Lozano, Andres M.
    [J]. BRAIN STIMULATION, 2018, 11 (06) : 1209 - 1217