Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study

被引:0
作者
Sibar, Kemal [1 ]
Alemdaroglu, Kadir Bahadir [1 ]
Elibol, Fatma Kubra Erbay [2 ]
Caliskan, Ozde Irem [2 ]
Demir, Teyfik [3 ]
机构
[1] SBU Ankara Training & Res Hosp, Ankara, Turkiye
[2] TOBB ETU, Biomed Engn, Ankara, Turkiye
[3] TOBB ETU Mech Engn, TR-06560 Ankara, Turkiye
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷 / 10期
关键词
Talon screw; Cannulated screw; Posterior column fracture; Acetabular fracture; Biomechanical; Axial loading; Static loading; Maximum torque; Dynamic loading; Stiffness; PERCUTANEOUS FIXATION; INTERNAL-FIXATION; BLOOD-LOSS; SCREW; REDUCTION; OUTCOMES; HIP;
D O I
10.1016/j.injury.2023.110964
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To compare the amount of displacement and rigidity at the fracture line under static & dynamic axial loading and torsional stress of conventional cannulated screw (CS), plate screw fixation including inter-fragmentary screw (PL), and talon cannulated compression device or talon screw in other words (TS) in posterior column fracture models. Synthetic hemipelvis bone models presenting a posterior column fracture were used in this study. Group PL, CS, and TS were created with ten bone models prepared for each group for dynamic and static loading tests and another ten for torsional tests. Rigidity and displacement amounts before and after loading were measured at the reference points AL, BL, and CL, located at the acetabulum's top, middle, and bottom, respectively. Torsional tests for each group were used to calculate torsional rigidity and maximum torque values. In dynamic axial loading tests, Group CS showed more displacement than PL at the BL point (p = 0,032) and Group TS at AL (p = 0,032) and CL (p = 0,004) points. In static axial loading tests, Group CS significantly displaced more than TS at AL and CL points (p = 0,05 and p = 0,014, respectively). Group PL and Group TS exhibited similar behavior in dynamic, static axial loading tests and torsional rigidity. The maximum torque that Group PL could withstand was statistically significantly higher than the other two groups (p <0,001). Talon cannulated screws had promising results in posterior column fractures of the acetabulum, which may decline the need for open surgery for stable fixation.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comparison of posterior ring fixation with combined anterior and posterior ring fixation for the treatment of lateral compression type 2 pelvic fractures
    Zhang, Bin-Fei
    Shang, Kun
    Wang, Peng-Fei
    Ke, Chao
    Han, Shuang
    Yang, Kun
    Fei, Chen
    Xu, Xin
    Zhang, Kun
    Zhuang, Yan
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (06) : 1187 - 1193
  • [42] Minimally Invasive Fixation of Fractures of the Phalanges and Metacarpals With Intramedullary Cannulated Headless Compression Screws
    del Pinal, Francisco
    Moraleda, Eduardo
    Ruas, Jaime S.
    de Piero, Guillermo H.
    Cerezal, Luis
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (04): : 692 - 700
  • [43] A BIOMECHANICAL STUDY OF ODONTOID FRACTURES AND FRACTURE FIXATION
    DOHERTY, BJ
    HEGGENESS, MH
    ESSES, SI
    SPINE, 1993, 18 (02) : 178 - 184
  • [44] Fractures of the posterior wall of the acetabulum: Treatment using internal fixation of two parallel reconstruction plates
    Li, Heng
    Yang, Honghang
    Wang, Dan
    Xu, Yi
    Min, Jikang
    Xu, Xuchun
    Li, Zhanchun
    Yuan, Yongjian
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (04): : 709 - 714
  • [45] Finite element analysis of the stability of combined plate internal fixation in posterior wall fractures of acetabulum
    Liu, Xi-Ming
    Pan, Chang-Wu
    Wang, Guo-Dong
    Cai, Xian-Hua
    Chen, Lei
    Meng, Cheng-Fei
    Huang, Jin-Cheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13393 - 13397
  • [46] Study of anatomical parameters and intraoperative fluoroscopic techniques for transiliac crest anterograde lag screws fixation of the posterior column of the acetabulum
    Yangyang Sun
    Jian Chen
    Fanxiao Liu
    Zhixue Chen
    Xiaohui Li
    Fuxin Lv
    Journal of Orthopaedic Surgery and Research, 18
  • [47] Primary stability of multi-hole acetabular cup combined with posterior column plating for the fixation of complex acetabular fractures in elderly patients: a biomechanical analysis
    Yan, Shuang G.
    Wang, Zhi
    Cui, Yiliang
    Hua, Xingyi
    Liu, Fanxiao
    Li, Di
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3697 - 3703
  • [48] An Alternative Patellar Fracture Fixation: A Biomechanical Study
    Banks, Kristine E.
    Ambrose, Catherine G.
    Wheeless, James S.
    Tissue, Camden M.
    Sen, Milan
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (06) : 345 - 351
  • [49] Biomechanical Evaluation of a New Device for Internal Fixation of Femoral Neck Fractures
    Yang, Ming
    Chen, Jianhai
    Zhang, Dianying
    Wang, Jing
    Yu, Kai
    Fu, Zhongguo
    Zhang, Hongbo
    Jiang, Baoguo
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2011, 39 (04): : 252 - 258
  • [50] Comparison of Cannulated Screw With Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (CompresSURE) in Patella Fractures-A Cadaveric Biomechanical Study
    Domby, Brian
    Henderson, Eric
    Nayak, Aniruddh
    Erdogan, Murat
    Gutierrez, Sergio
    Santoni, Brandon G.
    Sagi, H. Claude
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (12) : 678 - 683