Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study

被引:0
|
作者
Sibar, Kemal [1 ]
Alemdaroglu, Kadir Bahadir [1 ]
Elibol, Fatma Kubra Erbay [2 ]
Caliskan, Ozde Irem [2 ]
Demir, Teyfik [3 ]
机构
[1] SBU Ankara Training & Res Hosp, Ankara, Turkiye
[2] TOBB ETU, Biomed Engn, Ankara, Turkiye
[3] TOBB ETU Mech Engn, TR-06560 Ankara, Turkiye
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷 / 10期
关键词
Talon screw; Cannulated screw; Posterior column fracture; Acetabular fracture; Biomechanical; Axial loading; Static loading; Maximum torque; Dynamic loading; Stiffness; PERCUTANEOUS FIXATION; INTERNAL-FIXATION; BLOOD-LOSS; SCREW; REDUCTION; OUTCOMES; HIP;
D O I
10.1016/j.injury.2023.110964
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To compare the amount of displacement and rigidity at the fracture line under static & dynamic axial loading and torsional stress of conventional cannulated screw (CS), plate screw fixation including inter-fragmentary screw (PL), and talon cannulated compression device or talon screw in other words (TS) in posterior column fracture models. Synthetic hemipelvis bone models presenting a posterior column fracture were used in this study. Group PL, CS, and TS were created with ten bone models prepared for each group for dynamic and static loading tests and another ten for torsional tests. Rigidity and displacement amounts before and after loading were measured at the reference points AL, BL, and CL, located at the acetabulum's top, middle, and bottom, respectively. Torsional tests for each group were used to calculate torsional rigidity and maximum torque values. In dynamic axial loading tests, Group CS showed more displacement than PL at the BL point (p = 0,032) and Group TS at AL (p = 0,032) and CL (p = 0,004) points. In static axial loading tests, Group CS significantly displaced more than TS at AL and CL points (p = 0,05 and p = 0,014, respectively). Group PL and Group TS exhibited similar behavior in dynamic, static axial loading tests and torsional rigidity. The maximum torque that Group PL could withstand was statistically significantly higher than the other two groups (p <0,001). Talon cannulated screws had promising results in posterior column fractures of the acetabulum, which may decline the need for open surgery for stable fixation.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Transgluteal Posterior Column Screw Stabilization for Fractures of the Acetabulum: A Technical Trick
    Connelly, Camille L.
    Archdeacon, Michael T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) : E193 - E197
  • [22] Percutaneous Anterior Column Fixation for Acetabulum Fractures, Does It Have to Be Difficult?-The New Axial Pedicle View of the Anterior Column for Percutaneous Fixation
    Zhang, Lihai
    Zhang, Wei
    Mullis, Brian
    Liu, Daohong
    Xiong, Qi
    Lv, Houchen
    Ji, Xinran
    Peng, Ye
    Tang, Peifu
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (01) : E30 - E35
  • [23] A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall
    Wu, Xinbao
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (03) : 673 - 679
  • [24] A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures
    Han, Shuai
    Li, Dongdong
    Zhang, Peixun
    Yin, Xiaofeng
    Kou, Yuhui
    Han, Na
    Fu, Zhongguo
    ORTHOPEDICS, 2018, 41 (05) : E643 - E648
  • [25] Management of the posterior wall fracture in associated both column fractures of the acetabulum
    Michael J. Chen
    Ian Hollyer
    Harsh Wadhwa
    Seth S. Tigchelaar
    Noelle L. Van Rysselberghe
    Julius A. Bishop
    Michael J. Bellino
    Michael J. Gardner
    European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 1047 - 1054
  • [26] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964
  • [27] Antegrade versus retrograde screw fixation of anterior column acetabular fractures: a biomechanical in vitro study
    Georg Osterhoff
    Dag Wulsten
    Satish Babu
    Mark Heyland
    Carlotta Pari
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 1307 - 1312
  • [28] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [29] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [30] Study of anatomical parameters and intraoperative fluoroscopic techniques for transiliac crest anterograde lag screws fixation of the posterior column of the acetabulum
    Sun, Yangyang
    Chen, Jian
    Liu, Fanxiao
    Chen, Zhixue
    Li, Xiaohui
    Lv, Fuxin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)