Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study

被引:0
|
作者
Sibar, Kemal [1 ]
Alemdaroglu, Kadir Bahadir [1 ]
Elibol, Fatma Kubra Erbay [2 ]
Caliskan, Ozde Irem [2 ]
Demir, Teyfik [3 ]
机构
[1] SBU Ankara Training & Res Hosp, Ankara, Turkiye
[2] TOBB ETU, Biomed Engn, Ankara, Turkiye
[3] TOBB ETU Mech Engn, TR-06560 Ankara, Turkiye
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷 / 10期
关键词
Talon screw; Cannulated screw; Posterior column fracture; Acetabular fracture; Biomechanical; Axial loading; Static loading; Maximum torque; Dynamic loading; Stiffness; PERCUTANEOUS FIXATION; INTERNAL-FIXATION; BLOOD-LOSS; SCREW; REDUCTION; OUTCOMES; HIP;
D O I
10.1016/j.injury.2023.110964
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To compare the amount of displacement and rigidity at the fracture line under static & dynamic axial loading and torsional stress of conventional cannulated screw (CS), plate screw fixation including inter-fragmentary screw (PL), and talon cannulated compression device or talon screw in other words (TS) in posterior column fracture models. Synthetic hemipelvis bone models presenting a posterior column fracture were used in this study. Group PL, CS, and TS were created with ten bone models prepared for each group for dynamic and static loading tests and another ten for torsional tests. Rigidity and displacement amounts before and after loading were measured at the reference points AL, BL, and CL, located at the acetabulum's top, middle, and bottom, respectively. Torsional tests for each group were used to calculate torsional rigidity and maximum torque values. In dynamic axial loading tests, Group CS showed more displacement than PL at the BL point (p = 0,032) and Group TS at AL (p = 0,032) and CL (p = 0,004) points. In static axial loading tests, Group CS significantly displaced more than TS at AL and CL points (p = 0,05 and p = 0,014, respectively). Group PL and Group TS exhibited similar behavior in dynamic, static axial loading tests and torsional rigidity. The maximum torque that Group PL could withstand was statistically significantly higher than the other two groups (p <0,001). Talon cannulated screws had promising results in posterior column fractures of the acetabulum, which may decline the need for open surgery for stable fixation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Biomechanical performance of talon cannulated compression device in pauwels type III fractures: a comparative study
    Taskent, Hayri Can
    Alemdarog, Kadir Bahadir
    Uslan, Yunus
    Ercan, Niyazi
    Demir, Teyfik
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (11):
  • [2] Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws-A biomechanical study on standardized osteoporotic artificial bone
    Berk, Till
    Zderic, Ivan
    Schwarzenberg, Peter
    Pastor, Torsten
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Richards, Geoff
    Hierholzer, Christian
    Halvachizadeh, Sascha
    Pape, Hans-Christoph
    Gueorguiev, Boyko
    PLOS ONE, 2024, 19 (06):
  • [3] Antegrade Posterior Column Acetabulum Fracture Screw Fixation via Posterior Approach: A Biomechanical Comparative Study
    Berk, Till
    Zderic, Ivan
    Schwarzenberg, Peter
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Pfeifer, Roman
    Pastor, Tatjana
    Richards, Geoff
    Gueorguiev, Boyko
    Pape, Hans-Christoph
    MEDICINA-LITHUANIA, 2023, 59 (07):
  • [4] Biomechanical comparison of three different fixation techniques for anterior column posterior hemitransverse acetabular fractures using anterior intrapelvic approach
    Tanoglu, Oguzhan
    Alemdaroglu, Kadir Bahadir
    Iltar, Serkan
    Ozmeric, Ahmet
    Demir, Teyfik
    Erbay, Fatma Kubra
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1513 - 1519
  • [5] Fractures of the posterior wall of the acetabulum: treatment using cannulated screws
    Im, GI
    Chung, WS
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (08): : 782 - 786
  • [6] The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison
    Hinz, Nico
    Baumeister, Dirk
    Dehoust, Julius
    Muench, Matthias
    Frosch, Karl-Heinz
    Augat, Peter
    Hartel, Maximilian J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2573 - 2582
  • [7] Is cannulated-screw fixation an alternative to plate osteosynthesis in open book fractures? A biomechanical analysis
    Lazaro Gonzalvez, Angel
    Martinez Reina, Javier
    Cano Luis, Pedro
    Jimenez Baquero, Juan
    Sueiro Fernandez, Jose
    Giraldez Sanchez, Miguel Angel
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S72 - S77
  • [8] Clinical and radiological outcomes of antegrade posterior column screw fixation of the acetabulum
    Cavalie, Guillaume
    Boudissa, Mehdi
    Kerschbaumer, Gael
    Seurat, Olivier
    Ruatti, Sebastien
    Tonetti, Jerome
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (04)
  • [9] Comparison of Ordinary Cannulated Compression Screw and Double-Head Cannulated Compression Screw Fixation in Vertical Femoral Neck Fractures
    Zhang, Yuelei
    Yan, Chao
    Zhang, Lecheng
    Zhang, Wei
    Wang, Gang
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [10] Evaluation of cannulated compression headless screws as an alternative implant for superior pubic ramus fracture fixation: a biomechanical study
    Berk, Till
    Zderic, Ivan
    Schwarzenberg, Peter
    Pastor, Tatjana
    Lesche, Felix
    Halvachizadeh, Sascha
    Richards, R. Geoff
    Gueorguiev, Boyko
    Pape, Hans-Christoph
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (04) : 1079 - 1087