A Novel Scheme for Suppression of Human Motion Effects in Non-Contact Heart Rate Detection

被引:4
作者
Chen, Zekun [1 ]
Liu, Yunxue [1 ]
Sui, Chenhong [1 ]
Zhou, Min [1 ]
Song, Yuqing [1 ]
机构
[1] Yantai Univ, Sch Phys & Elect Informat, Yantai 264005, Peoples R China
基金
中国国家自然科学基金;
关键词
APSEM method; frequency-modulated continuous-wave (FMCW) radar; human motion; KFRV method; MCA; non-contact heart rate detection; VITAL SIGNS DETECTION; EXTRACTION;
D O I
10.1109/ACCESS.2023.3302918
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The technology of non-contact heart rate detection has been proven of great use. However, it is still limited by several challenges, particularly the influence of human motion and random disturbances, which significantly degrade the accuracy of the measurement. To address these challenges, this paper proposes a novel scheme for heart rate detection. Firstly, the proposed scheme utilizes the Multi-Channel Averaging (MCA) technique to improve the signal-to-noise ratio (SNR) of the extracted phase signal from the echoes in the multiple receivers, and a high-pass filter to roughly extract a heartbeat signal. Secondly, to suppress motion artifacts (MA) in the heartbeat signal caused by human motion, the Adaptive Parameter Selection for Expectation-Maximization (APSEM) method is proposed. Further, a novel processing sub-framework which combines the Kalman filtering, the Variational Mode Extraction (VME) algorithm, and the Rife spectral analysis method (called KFRV method) is proposed to mitigate the effect of random disturbances and achieve accurate frequency estimation. Experimental results using the Polar H10 heart rate sensor as a reference show that the proposed scheme achieves accurate heart rate detection in the presence of human motion, with the Mean Absolute Error (MAE) of less than 2.5 beats per minute (bpm), which is much better than traditional schemes. Compared to traditional methods, the proposed scheme exhibits negligible loss in heart rate detection under static state, with an average MAE of 0.99 bpm. Overall, the experimental results demonstrate the applicability of the proposed scheme for accurate heart rate detection in both human motion and static states.
引用
收藏
页码:84241 / 84257
页数:17
相关论文
共 35 条
[1]   Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar [J].
Alizadeh, Mostafa ;
Shaker, George ;
Martins De Almeida, Joao Carlos ;
Morita, Plinio Pelegrini ;
Safavi-Naeini, Safeddin .
IEEE ACCESS, 2019, 7 :54958-54968
[2]   Improved Contactless Heartbeat Estimation in FMCW Radar via Kalman Filter Tracking [J].
Arsalan, Muhammad ;
Santra, Avik ;
Will, Christoph .
IEEE SENSORS LETTERS, 2020, 4 (05)
[3]  
Chen Zekun, 2022, 2022 Global Reliability and Prognostics and Health Management (PHM-Yantai), P1, DOI 10.1109/PHM-Yantai55411.2022.9942111
[4]   Variational Mode Decomposition [J].
Dragomiretskiy, Konstantin ;
Zosso, Dominique .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2014, 62 (03) :531-544
[5]  
Ernst R., 2017, P IEEE SENSORS, P1
[6]  
He Y., 2016, Radar Data Processing With Applications
[7]  
[侯培国 Hou Peiguo], 2014, [传感器与微系统, Transducer and Microsystem Technology], V33, P1
[8]  
Ji S., 2022, THESIS SE U JIANGSU
[9]  
Jing Y., 2021, China Med. Devices, V36, P1
[10]   Human Vital Signs Detection Methods and Potential Using Radars: A Review [J].
Kebe, Mamady ;
Gadhafi, Rida ;
Mohammad, Baker ;
Sanduleanu, Mihai ;
Saleh, Hani ;
Al-Qutayri, Mahmoud .
SENSORS, 2020, 20 (05)