Precision of Ultrasound-Guided versus Anatomical Palpation-Guided Needle Placement of the Ulnar Nerve at the Cubital Tunnel: A Cadaveric Study

被引:2
|
作者
Lopez-de-Celis, Carlos [1 ,2 ,3 ]
Fernandez-de-Las-Penas, Cesar [4 ]
Malo-Urries, Miguel [5 ]
Albarova-Corral, Isabel [5 ]
Arias-Buria, Jose L. [4 ]
Perez-Bellmunt, Albert [1 ,2 ]
Rodriguez-Sanz, Jacobo [1 ,2 ]
Gonzalez-Rueda, Vanessa [1 ,2 ,3 ]
Borella-Andres, Sergio [5 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Barcelona 08028, Spain
[2] ACTIUM Funct Anat Grp, Barcelona 08028, Spain
[3] Univ Recerca Atencio, Fundacio Inst, Primaria Salut Jordi Gol i Gurina IDIAPJGol, Barcelona 08028, Spain
[4] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys, Alcorcon 28922, Spain
[5] Univ Zaragoza, Hlth Sci Fac, Dept Physiatry & Nursery, Zaragoza 50009, Spain
关键词
needle; ultrasound; ulnar nerve; cubital tunnel; accuracy; palpation; REGIONAL ANESTHESIA; BRACHIAL-PLEXUS; STIMULATION; NEUROSTIMULATION; PAIN;
D O I
10.3390/healthcare11111603
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 +/- 1.37 vs. 2.01 +/- 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 +/- 23.19 vs. 24.57 +/- 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Evaluation of the Effectiveness and Safety of Ultrasound-Guided Percutaneous Carpal Tunnel Release A Cadaveric Study
    Burnham, Robert
    Playfair, Larry
    Loh, Eldon
    Roberts, Shannon
    Agur, Anne
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2017, 96 (07) : 457 - 463
  • [42] A PROSPECTIVE COMPARISON OF ULTRASOUND GUIDED VERSUS PALPATION METHOD FOR RADIAL ARTERY CATHETER PLACEMENT
    Kumar, Kamal
    Khuwaja, Amin Muhammad
    Mangi, Ali Raza
    Khan, Sajjad Ahmed
    Tariq, Hamna
    Zaheeruddin, Sayed
    Akhtar, Saleha
    PAKISTAN HEART JOURNAL, 2023, 56 (01): : 28 - 32
  • [43] Palpation Versus Ultrasound-Guided Acromioclavicular Joint Intra-articular Corticosteroid Injections: A Retrospective Comparative Clinical Study
    Park, Ki Deok
    Kim, Tai Kon
    Lee, Jihae
    Lee, Woo Yong
    Ahn, Jae Ki
    Park, Yongbum
    PAIN PHYSICIAN, 2015, 18 (04) : 333 - 341
  • [44] Development of an ultrasound-guided technique for retrobulbar nerve block in dromedary camels: a cadaveric study
    Badawy, Adel M.
    Eshra, Eman A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2018, 45 (02) : 175 - 182
  • [45] An anatomical study of so-called fibrous bands around the ulnar nerve distal to the cubital tunnel
    Guedes-Correa, Jose Fernando
    Brown, Rosana Siqueira
    ACTA NEUROCHIRURGICA, 2018, 160 (08) : 1591 - 1596
  • [46] An anatomical study of so-called fibrous bands around the ulnar nerve distal to the cubital tunnel
    José Fernando Guedes-Correa
    Rosana Siqueira Brown
    Acta Neurochirurgica, 2018, 160 : 1591 - 1596
  • [47] The Maximum Effective Needle-to-Nerve Distance for Ultrasound-Guided Interscalene Block An Exploratory Study
    Albrecht, Eric
    Kirkham, Kyle R.
    Taffe, Patrick
    Endersby, Ryan V. W.
    Chan, Vincent W. S.
    Tse, Cyrus
    Brull, Richard
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2014, 39 (01) : 56 - 60
  • [48] Ultrasound-guided approach to nerves (direct vs. tangential) and the incidence of intraneural injection: a cadaveric study
    Sermeus, L. A.
    Sala-Blanch, X.
    McDonnell, J. G.
    Lobo, C. A.
    Nicholls, B. J.
    van Geffen, G. J.
    Choquet, O.
    Iohom, G.
    Maria Galve, B. de Jose
    Hermans, C.
    Lammens, M.
    ANAESTHESIA, 2017, 72 (04) : 461 - 469
  • [49] Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses
    Okasha, Hussein Hassan
    Naga, Mazen Ibrahim
    Esmat, Serag
    Naguib, Mohamed
    Hassanein, Mohamed
    Hassani, Mohamed
    El-Kassas, Mohamed
    Mahdy, Reem Ezzat
    El-Gemeie, Emad
    Farag, Ali Hassan
    Foda, Ayman Mohamed
    ENDOSCOPIC ULTRASOUND, 2013, 2 (04) : 190 - 193
  • [50] Ultrasound-Guided Versus Palpation-Guided Techniques to Achieve Vascular Access in Children Undergoing Cardiac Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials
    Ibrahim, Ahmed A.
    Allam, Abdallah R.
    Amin, Ahmed Mazen
    Rakab, Mohamed Saad
    Alhadeethi, Abdulhameed
    Hageen, Ahmed W.
    Mahmoud, Abdelrahman
    Abuelazm, Mohamed
    Abdelazeem, Basel
    PEDIATRIC CARDIOLOGY, 2024,