Precision of Ultrasound-Guided versus Anatomical Palpation-Guided Needle Placement of the Ulnar Nerve at the Cubital Tunnel: A Cadaveric Study

被引:2
|
作者
Lopez-de-Celis, Carlos [1 ,2 ,3 ]
Fernandez-de-Las-Penas, Cesar [4 ]
Malo-Urries, Miguel [5 ]
Albarova-Corral, Isabel [5 ]
Arias-Buria, Jose L. [4 ]
Perez-Bellmunt, Albert [1 ,2 ]
Rodriguez-Sanz, Jacobo [1 ,2 ]
Gonzalez-Rueda, Vanessa [1 ,2 ,3 ]
Borella-Andres, Sergio [5 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Barcelona 08028, Spain
[2] ACTIUM Funct Anat Grp, Barcelona 08028, Spain
[3] Univ Recerca Atencio, Fundacio Inst, Primaria Salut Jordi Gol i Gurina IDIAPJGol, Barcelona 08028, Spain
[4] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys, Alcorcon 28922, Spain
[5] Univ Zaragoza, Hlth Sci Fac, Dept Physiatry & Nursery, Zaragoza 50009, Spain
关键词
needle; ultrasound; ulnar nerve; cubital tunnel; accuracy; palpation; REGIONAL ANESTHESIA; BRACHIAL-PLEXUS; STIMULATION; NEUROSTIMULATION; PAIN;
D O I
10.3390/healthcare11111603
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 +/- 1.37 vs. 2.01 +/- 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 +/- 23.19 vs. 24.57 +/- 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Cadaveric Model Simulations for Training in Ultrasound-Guided Percutaneous Placement of a Novel Peripheral Nerve Stimulation Electrode
    Gazzeri, Roberto
    Piraccini, Emanuele
    Cesaroni, Alessandro
    Micheli, Fabrizio
    Amorizzo, Ezio
    Raggi, Massimiliano
    Occhigrossi, Felice
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [22] Morphology of the Cubital Tunnel: An Anatomical and Biomechanical Study With Implications for Treatment of Ulnar Nerve Compression
    James, Jaison
    Sutton, Levi G.
    Werner, Frederick W.
    Basu, Niladri
    Allison, Mari A.
    Palmer, Andrew K.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (12): : 1988 - 1995
  • [23] Ultrasound-guided block of sciatic and femoral nerves: an anatomical study
    Waag, Sonja
    Stoffel, Michael H.
    Spadavecchia, Claudia
    Eichenberger, Urs
    Rohrbach, Helene
    LABORATORY ANIMALS, 2014, 48 (02) : 97 - 104
  • [24] Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study
    Patel, Deepan N.
    Nayyar, Samir
    Hasan, Saqib
    Khatib, Omar
    Sidash, Stanislav
    Jazrawi, Laith M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (12) : 1664 - 1668
  • [25] Ultrasound-Guided Pudendal Nerve Block versus Ultrasound-Guided Dorsal Penile Nerve Block for Pediatric Distal Hypospadias Surgery
    Ozen, Volkan
    Ozen, Nurten
    UROLOGIA INTERNATIONALIS, 2023, 107 (04) : 370 - 376
  • [26] Ultrasound-guided midthigh sciatic nerve block - A clinical and anatomical study
    Barrington, Michael J.
    Lai, Su-Ling K.
    Briggs, Chris A.
    Ivanusic, Jason J.
    Gledhill, Samuel R.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2008, 33 (04) : 369 - 376
  • [27] Assessing the Accuracy of Ultrasound-Guided Needle Placement in Sacroiliac Joint Injections
    De Luigi, Arthur Jason
    Saini, Vikramjeet
    Mathur, Rajat
    Saini, Amanpreet
    Yokel, Nathan
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2019, 98 (08) : 666 - 670
  • [28] Ultrasound-guided versus Nonguided Tibiotalar Joint and Sinus Tarsi Injections: A Cadaveric Study
    Wisniewski, Steve J.
    Smith, Jay
    Patterson, Denis G.
    Carmichael, Stephen W.
    Pawlina, Wojciech
    PM&R, 2010, 2 (04) : 277 - 281
  • [29] Cadaveric ultrasound imaging for training in ultrasound-guided peripheral nerve blocks: Upper extremity
    Ban C. H. Tsui
    Derek Dillane
    Anil H. Walji
    Canadian Journal of Anesthesia, 2007, 54
  • [30] Ultrasound-Guided versus Palpation-Guided Radial Artery Catheterization in Adult Population: Updated Meta-Analysis and Systematic Review of Randomized Controlled Trials
    Moussa, Pacha Homam
    Soud, Mohamad
    Alahdab, Fares
    Khadra, Yasser
    Darmoch, Fahed
    Kaki, Amir
    Alraies, M. Chadi
    CIRCULATION, 2018, 138