Different reactivities of H3O+(H2O)n with unsaturated and saturated aldehydes: ligand-switching reactions govern the quantitative analytical sensitivity of SESI-MS

被引:6
作者
Spanel, Patrik [1 ]
Dryahina, Kseniya [1 ]
Omezzine Gnioua, Maroua [1 ,2 ]
Smith, David [1 ]
机构
[1] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 8, Czech Republic
[2] Charles Univ Prague, Fac Math & Phys, Dept Surface & Plasma Sci, Prague, Czech Republic
关键词
ION FLOW TUBE; ELECTROSPRAY-IONIZATION; SIFT; H3O+; BREATH; NO+; O-2(+); SERIES; AIR;
D O I
10.1002/rcm.9496
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleThe detection sensitivity of secondary electrospray ionisation mass spectrometry (SESI-MS) is much lower for saturated aldehydes than for unsaturated aldehydes. This needs to be understood in terms of gas phase ion-molecule reaction kinetics and energetics to make SESI-MS analytically more quantitative. MethodsParallel SESI-MS and selected ion flow tube mass spectrometry (SIFT-MS) analyses were carried out of air containing variable accurately determined concentrations of saturated (C5, pentanal; C7, heptanal; C8 octanal) and unsaturated (C5, 2-pentenal; C7, 2-heptenal; C8, 2-octenal) aldehyde vapours. The influence of the source gas humidity and the ion transfer capillary temperature, 250 and 300 degrees C, in a commercial SESI-MS instrument was explored. Separate experiments were carried out using SIFT to determine the rate coefficients, k(73), for the ligand-switching reactions of the H3O+(H2O)(3) ions with the six aldehydes. ResultsThe relative slopes of the plots of SESI-MS ion signal against SIFT-MS concentration were interpreted as the relative SESI-MS sensitivities for these six compounds. The sensitivities for the unsaturated aldehydes were 20 to 60 times greater than for the corresponding C5, C7 and C8 saturated aldehydes. Additionally, the SIFT experiments revealed that the measured k(73) are three or four times greater for the unsaturated than for the saturated aldehydes. ConclusionsThe trends in SESI-MS sensitivities are rationally explained by differences in the rates of the ligand-switching reactions, which are justified by theoretically calculated equilibrium rate constants derived from thermochemical density functional theory (DFT) calculations of Gibb's free energy changes. The humidity of SESI gas thus favours the reverse reactions of the saturated aldehyde analyte ions, effectively suppressing their signals in contrast to their unsaturated counterparts.
引用
收藏
页数:10
相关论文
共 28 条
[1]   Extension of the D3 dispersion coefficient model [J].
Caldeweyher, Eike ;
Bannwarth, Christoph ;
Grimme, Stefan .
JOURNAL OF CHEMICAL PHYSICS, 2017, 147 (03)
[2]   Ionization of vapor molecules by an electrospray cloud [J].
de la Mora, Juan Fernandez .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 300 (2-3) :182-193
[3]   Optimisation of secondary electrospray ionisation (SESI) for the trace determination of gas-phase volatile organic compounds [J].
Dillon, Leonard A. ;
Stone, Victoria N. ;
Croasdell, Laura A. ;
Fielden, Peter R. ;
Goddard, Nicholas J. ;
Thomas, C. L. Paul .
ANALYST, 2010, 135 (02) :306-314
[4]   Sensitivity of secondary electrospray ionization mass spectrometry to a range of volatile organic compounds: Ligand switching ion chemistry and the influence of Zspray™ guiding electric fields [J].
Dryahina, Kseniya ;
Polasek, Miroslav ;
Smith, David ;
Spanel, Patrik .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (22)
[5]   Reagent and analyte ion hydrates in secondary electrospray ionization mass spectrometry (SESI-MS), their equilibrium distributions and dehydration in an ion transfer capillary: Modelling and experiments [J].
Dryahina, Kseniya ;
Som, Suman ;
Smith, David ;
Spanel, Patrik .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (07)
[6]   Avogadro: an advanced semantic chemical editor, visualization, and analysis platform [J].
Hanwell, Marcus D. ;
Curtis, Donald E. ;
Lonie, David C. ;
Vandermeersch, Tim ;
Zurek, Eva ;
Hutchison, Geoffrey R. .
JOURNAL OF CHEMINFORMATICS, 2012, 4
[7]   How Soft Is Secondary Electrospray Ionization? [J].
Kaeslin, Jerome ;
Wuethrich, Cedric ;
Giannoukos, Stamatios ;
Zenobi, Renato .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (10) :1967-1974
[8]   Minimizing ion competition boosts volatile metabolome coverage by secondary electrospray ionization orbitrap mass spectrometry [J].
Lan, Jiayi ;
Kaeslin, Jerome ;
Greter, Giorgia ;
Zenobi, Renato .
ANALYTICA CHIMICA ACTA, 2021, 1150
[9]   Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry [J].
Liu, Chao ;
Zeng, Jiafa ;
Sinues, Pablo ;
Fang, Mingliang ;
Zhou, Zhen ;
Li, Xue .
ANALYTICA CHIMICA ACTA, 2021, 1180
[10]   Electrospray ionization of volatiles in breath [J].
Martinez-Lozano, P. ;
Fernandez de la Mora, J. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 265 (01) :68-72