An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma

被引:6
|
作者
Engel, Anett [1 ]
Ruhe, Lena [1 ]
Singh, Neeraj [2 ]
Wright, Jo Anne [2 ]
Liesch, Franziska [2 ]
Bauland, Friederike [3 ]
Ostermann, Annika I. I. [1 ]
Sumalowitsch, Tamara [1 ]
Schweinsberg, Vincent J. T. [4 ]
Geistanger, Andrea [2 ]
Hegel, Johannes Kolja [1 ]
Geletneky, Christian [2 ]
Taibon, Judith [2 ,5 ]
机构
[1] Lab Berlin Charite Vivantes Serv GmbH, Collaborat & Innovat Management, Dept Studies, Berlin, Germany
[2] Roche Diagnost GmbH, Berlin, Germany
[3] Chrestos Concept GmbH & Co KG, Essen, Germany
[4] Lab Berlin Charite Vivantes GmbH, Dept Lab Med & Toxicol, Berlin, Germany
[5] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
关键词
isotope dilution LC-MS/MS; methotrexate; qNMR; reference measurement procedure; SI units; traceability; LC-MS/MS ASSAY; PHARMACOKINETICS; VALIDATION; METABOLITE; CHILDREN;
D O I
10.1515/cclm-2022-1001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma.Methods: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines.Results: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 mu mol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was <= 4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4. 5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was <= 3.4%.Conclusions: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.
引用
收藏
页码:1917 / 1929
页数:13
相关论文
共 50 条
  • [42] Dried plasma spot-based liquid chromatography-tandem mass spectrometry for the quantification of methotrexate in human plasma and its application in therapeutic drug monitoring
    Cao, Haiwei
    Li, Li
    Wang, Shaomin
    Guo, Haiyang
    Ren, Wenbo
    Li, Yanyan
    Huang, Jing
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (06) : 1153 - 1161
  • [43] Determination of plasma Levetiracetam level by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS-MS) and its application in pharmacokinetics studies in neonates
    Jenjirattithigarn, Nuttawut
    Worachat, Nattha
    Horsuwan, Suchawadee
    Puangpetch, Apichaya
    Prempunpong, Chatchay
    Khongkhatithum, Chaiyos
    Thampratankul, Lunliya
    Prommas, Santirat
    Visudtibhan, Anannit
    Sukasem, Chonlaphat
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1085 : 13 - 20
  • [44] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Assay for the Determination of Total and Unbound Ciprofloxacin Concentrations in Human Plasma
    de Vroom, Suzanne L.
    Pistorius, Marcel C. M.
    Bijleveld, Yuma A.
    Geerlings, Suzanne E.
    Mathot, Ron A. A.
    van Hest, Reinier M.
    Jager, Nynke G. L.
    THERAPEUTIC DRUG MONITORING, 2022, 44 (04) : 552 - 557
  • [45] Development and validation of a simple isotope dilution-liquid chromatography-tandem mass spectrometry method for detecting vitamins A and E in serum and amniotic fluid
    Yu, Songlin
    Yin, Yicong
    Wang, Danchen
    Xie, Shaowei
    Cheng, Qian
    Cheng, Xinqi
    Qiu, Ling
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 435 : 118 - 123
  • [46] Isotope-dilution liquid chromatography-tandem mass spectrometry method for serum beta 2-microglobulin quantification
    Yang, Sheng
    Tian, Xue
    Chen, Yu
    Shen, Lei
    Wang, Jianxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1211
  • [47] Quantification of 5,7-dimethoxyflavone in mouse plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and its application to a pharmacokinetic study
    Bei, Di
    An, Guohua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 978 : 11 - 17
  • [48] An isotope dilution LC-MS/MS based candidate reference method for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood
    Taibon, Judith
    van Rooij, Milou
    Schmid, Rupert
    Singh, Neeraj
    Albrecht, Eva
    Wright, Jo Anne
    Geletneky, Christian
    Schuster, Carina
    Moerlein, Sophie
    Vogeser, Michael
    Seger, Christoph
    Pongratz, Stephan
    Kobold, Uwe
    CLINICAL BIOCHEMISTRY, 2020, 82 : 73 - 84
  • [49] Comparison of the docetaxel concentration in human plasma measured with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and a nanoparticle immunoassay and clinical applications of that assay
    Geng, Chunmei
    Li, Pingli
    Chen, Xuwang
    Yuan, Guiyan
    Guo, Nan
    Liu, Huanjun
    Zhang, Rui
    Guo, Ruichen
    BIOSCIENCE TRENDS, 2017, 11 (02) : 202 - 208
  • [50] Determination of 2-hydroxyflutamide in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS): Application to a bioequivalence study on Chinese volunteers
    Zheng, Heng
    Wu, Dan
    Qian, Zhen-yu
    Xiang, Yi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1611 - 1615