An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma

被引:6
|
作者
Engel, Anett [1 ]
Ruhe, Lena [1 ]
Singh, Neeraj [2 ]
Wright, Jo Anne [2 ]
Liesch, Franziska [2 ]
Bauland, Friederike [3 ]
Ostermann, Annika I. I. [1 ]
Sumalowitsch, Tamara [1 ]
Schweinsberg, Vincent J. T. [4 ]
Geistanger, Andrea [2 ]
Hegel, Johannes Kolja [1 ]
Geletneky, Christian [2 ]
Taibon, Judith [2 ,5 ]
机构
[1] Lab Berlin Charite Vivantes Serv GmbH, Collaborat & Innovat Management, Dept Studies, Berlin, Germany
[2] Roche Diagnost GmbH, Berlin, Germany
[3] Chrestos Concept GmbH & Co KG, Essen, Germany
[4] Lab Berlin Charite Vivantes GmbH, Dept Lab Med & Toxicol, Berlin, Germany
[5] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
关键词
isotope dilution LC-MS/MS; methotrexate; qNMR; reference measurement procedure; SI units; traceability; LC-MS/MS ASSAY; PHARMACOKINETICS; VALIDATION; METABOLITE; CHILDREN;
D O I
10.1515/cclm-2022-1001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma.Methods: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines.Results: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 mu mol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was <= 4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4. 5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was <= 3.4%.Conclusions: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.
引用
收藏
页码:1917 / 1929
页数:13
相关论文
共 50 条
  • [31] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify serum voriconazole
    Mak, Justin
    Sujishi, Kirk K.
    French, Deborah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 94 - 99
  • [32] Comparison of bracketing calibration and classical calibration curve quantification methods in establishing a candidate reference measurement procedure for human serum 17β-estradiol by isotope dilution liquid chromatography tandem mass spectrometry
    Zhang, Qiaoxuan
    Cai, Zhiliang
    Liu, Yingyi
    Lin, Haibiao
    Wang, Qiqin
    Yan, Jun
    Han, Liqiao
    Wang, Jianbing
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    MICROCHEMICAL JOURNAL, 2020, 152
  • [33] Quantitation of Phenolic Benzotriazole Class Compounds in Plasma by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Mutlu, Esra
    South, Natalie
    Pierfelice, Jessica
    Djonabaye, Alison
    Pauff, Mindy
    Burback, Brian
    Waidyanatha, Suramya
    ANALYTICAL LETTERS, 2022, 55 (13) : 2074 - 2088
  • [34] Rapid and accurate method for quantifying busulfan in plasma samples by isocratic liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Villena-Ortiz, Yolanda
    Castellote-Belles, Laura
    Martinez-Sanchez, Luisa
    Benitez-Carabante, Maria I.
    Miarons, Marta
    Vima-Bofarull, Jaume
    Barquin-DelPino, Raquel
    Paciucci, Rosanna
    Rodriguez-Frias, Francisco
    Ferrer-Costa, Roser
    Casis, Ernesto
    Lopez-Hellin, Joan
    ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2022, 3 (03): : 263 - 271
  • [35] Measurement of serum 17-hydroxyprogesterone using isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method and evaluation of the performance for three routine methods
    Long, Qichen
    Zhang, Tianjiao
    Yan, Ying
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Li, Shuijun
    Zhang, Jiangtao
    Zeng, Qingzhang
    Zhao, Beibei
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) : 523 - 532
  • [36] Measurement of progesterone in human serum by isotope dilution liquid chromatography-tandem mass spectrometry and comparison with the commercial chemiluminescence immunoassay
    Lee, Hwashim
    Park, Chang Joon
    Lee, Gaeho
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1713 - 1719
  • [37] A high-accuracy measurement procedure for salbutamol, ractopamine, and clenbuterol in pork by isotope dilution-liquid chromatography/tandem mass spectrometry
    Zhou, Xia
    Tian, Tian
    Li, Xiuqin
    Liu, Shuyu
    Zhang, Qinghe
    FOOD CHEMISTRY, 2024, 459
  • [38] A reference measurement procedure for amino acids in blood using isotope dilution ultra-performance liquid chromatography-tandem mass spectrometry
    Kim, Juok
    Tran, Thi Thanh Huong
    Hong, Seon-Pyo
    Jeong, Ji-Seon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1055 : 72 - 80
  • [39] An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma
    Moosavi, Seyed Mojtaba
    Shekar, Kiran
    Fraser, John F.
    Smith, Maree T.
    Ghassabian, Sussan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 : 118 - 122
  • [40] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues
    Munyeza, Chiedza F.
    Shobo, Adeola
    Baijnath, Sooraj
    Bratkowska, Dominika
    Naiker, Suhashni
    Bester, Linda A.
    Singh, Sanil D.
    Maguire, Glenn E. M.
    Kruger, Hendrik G.
    Naicker, Tricia
    Govender, Thavendran