An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma

被引:6
|
作者
Engel, Anett [1 ]
Ruhe, Lena [1 ]
Singh, Neeraj [2 ]
Wright, Jo Anne [2 ]
Liesch, Franziska [2 ]
Bauland, Friederike [3 ]
Ostermann, Annika I. I. [1 ]
Sumalowitsch, Tamara [1 ]
Schweinsberg, Vincent J. T. [4 ]
Geistanger, Andrea [2 ]
Hegel, Johannes Kolja [1 ]
Geletneky, Christian [2 ]
Taibon, Judith [2 ,5 ]
机构
[1] Lab Berlin Charite Vivantes Serv GmbH, Collaborat & Innovat Management, Dept Studies, Berlin, Germany
[2] Roche Diagnost GmbH, Berlin, Germany
[3] Chrestos Concept GmbH & Co KG, Essen, Germany
[4] Lab Berlin Charite Vivantes GmbH, Dept Lab Med & Toxicol, Berlin, Germany
[5] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
关键词
isotope dilution LC-MS/MS; methotrexate; qNMR; reference measurement procedure; SI units; traceability; LC-MS/MS ASSAY; PHARMACOKINETICS; VALIDATION; METABOLITE; CHILDREN;
D O I
10.1515/cclm-2022-1001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma.Methods: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines.Results: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 mu mol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was <= 4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4. 5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was <= 3.4%.Conclusions: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.
引用
收藏
页码:1917 / 1929
页数:13
相关论文
共 50 条
  • [21] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Zhang, Qiaoxuan
    Zhang, Lu
    Lin, Haibiao
    Cai, Zhiliang
    Yan, Jun
    Wang, Qiqin
    Han, Liqiao
    Wang, Jianbing
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (27) : 7095 - 7104
  • [22] An isotope dilution LC-MS/MS-based candidate reference method for the quantification of androstenedione in human serum and plasma
    Gradl, Katrin
    Taibon, Judith
    Singh, Neeraj
    Albrecht, Eva
    Geistanger, Andrea
    Pongratz, Stephan
    Hutzler, Stefan
    Mayer, Magdalena
    Kleinschmidt, Christine
    Geletneky, Christian
    Hofmann, Verena
    Koeppl, Daniel
    Rauh, Manfred
    Kobold, Uwe
    CLINICAL MASS SPECTROMETRY, 2020, 16 : 1 - 10
  • [23] Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry
    Han, Liqiao
    Huang, Xiaoting
    Zhang, Lu
    Zhang, Qiaoxuan
    Wang, Jianbing
    Lin, Haibiao
    Yan, Jun
    Zhuang, Junhua
    Huang, Xianzhang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 124 - 129
  • [24] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Bei Xu
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1087 - 1094
  • [25] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1087 - 1094
  • [26] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography–tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Qiaoxuan Zhang
    Lu Zhang
    Haibiao Lin
    Zhiliang Cai
    Jun Yan
    Qiqin Wang
    Liqiao Han
    Jianbing Wang
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7095 - 7104
  • [27] Isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedures for the quantification of 24(R),25-dihydroxyvitamin D2 and 24(R),25-dihydroxyvitamin D3 in human serum and plasma
    Kandler, Kerstin
    Stadlmeier, Michael
    Singh, Neeraj
    Bauland, Friederike
    Geistanger, Andrea
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
  • [28] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of voriconazole in human cerebrospinal fluid
    Dong, Liuhan
    Bai, Nan
    Wang, Tianlin
    Cai, Yun
    ANALYTICAL METHODS, 2021, 13 (39) : 4585 - 4593
  • [29] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of free and total dabigatran in human plasma and its application to a pharmacokinetic study
    Shaikh, Khurshid
    Mungantiwar, Ashish
    Halde, Supriya
    Pandita, Nancy
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2021, 47 (11) : 1835 - 1846
  • [30] Isotope-dilution liquid chromatography-tandem mass spectrometry for quantification of human retinol binding protein 4 in serum
    Tian, Xue
    Yang, Sheng
    Tang, Qu
    Ji, Huoyan
    Shen, Lei
    Wang, Jianxin
    ANALYTICAL BIOCHEMISTRY, 2022, 645