Gravity compensation of a 2R1T mechanism with remote center of motion for minimally invasive transnasal surgery applications

被引:4
作者
Aldanmaz, Ataol Behram [1 ]
Ayit, Orhan [1 ]
Kiper, Gokhan [1 ]
机构
[1] Izmir Inst Technol, Dept Mech Engn, TR-35430 Izmir, Turkey
关键词
static balancing; gravity compensation; surgical robots; parallel manipulators; remote center of motion; DESIGN;
D O I
10.1017/S0263574722000534
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This work addresses the gravity balancing of a 2R1T (2 rotations - 1 translation) mechanism with remote center of motion. A previously developed balancing solution is modified and applied to a prototype, and test results are presented. The mechanism is an endoscope holder for minimally invasive transnasal pituitary gland surgery. In this surgery, the endoscope is inserted through a nostril of the patient through a natural path to the pituitary gland. During the surgery, it is vital for the manipulator to be statically balanced so that in case of a motor failure, the patient is protected against any harmful motion of the endoscope. Additionally, static balancing takes the gravitational load from the actuators and hence facilitates the control of the mechanism. The mechanism is a 2URRR-URR type parallel manipulator with three legs. The payload mass is distributed to the legs on the sides. By using counter-masses for two links of each leg, the center of mass of each leg is lumped on the proximal link which simplifies the problem of balancing of a two degree-of-freedom inverted pendulum. The two proximal links with the lumped mass are statically balanced via springs. Dynamic simulations indicate that when the mechanism is statically balanced, generated actuator torques are reduced by 93.5%. Finally, the balancing solution is implemented on the prototype of the manipulator. The tests indicate that the manipulator is statically balanced within its task space when the actuators are disconnected. When the actuators are connected, the torque requirements decrease by about 37.8% with balancing.
引用
收藏
页码:807 / 820
页数:14
相关论文
共 12 条
[1]   Human-Robot Interfaces of the NeuRoboScope: A Minimally Invasive Endoscopic Pituitary Tumor Surgery Robotic Assistance System [J].
Dede, Mehmet Ismet Can ;
Kiper, Gokhan ;
Ayav, Tolga ;
Ozdemirel, Barbaros ;
Tatlicioglu, Enver ;
Hanalioglu, Sahin ;
Isikay, Ilkay ;
Berker, Mustafa .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2021, 15 (01)
[2]  
Herder J.L., 2001, ENERGY FREE SYSTEMS
[3]  
Jean M, 1996, IEEE INT CONF ROBOT, P3732, DOI 10.1109/ROBOT.1996.509282
[4]  
Maaroof O., 2021, INT J ADV ROBOT SYST, V18, P1
[5]  
Maaroof O. W. N., 2020, THESIS IZMIR I TECHN
[6]   Algorithm for the static balancing of serial and parallel mechanisms combining counterweights and springs: Generation, assessment and ranking of effective design variants [J].
Martini, Alberto ;
Troncossi, Marco ;
Rivola, Alessandro .
MECHANISM AND MACHINE THEORY, 2019, 137 :336-354
[7]   Static balancing of a parallel kinematics machine with Linear-Delta architecture: theory, design and numerical investigation [J].
Martini, Alberto ;
Troncossi, Marco ;
Carricato, Marco ;
Rivola, Alessandro .
MECHANISM AND MACHINE THEORY, 2015, 90 :128-141
[8]   Static balancing of parallel robots [J].
Russo, A ;
Sinatra, R ;
Xi, FF .
MECHANISM AND MACHINE THEORY, 2005, 40 (02) :191-202
[9]   Energy-free adjustment of gravity equilibrators by adjusting the spring stiffness [J].
van Dorsser, W. D. ;
Barents, R. ;
Wisse, B. M. ;
Schenk, M. ;
Herder, J. L. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (09) :1839-1846
[10]   A geometric approach to the static balancing of mechanisms constructed using spherical kinematic chain units [J].
Wang, Jieyu ;
Kong, Xianwen .
MECHANISM AND MACHINE THEORY, 2019, 140 :305-320