Closed-Loop Insulin Delivery Systems for People with Type 1 Diabetes and Chronic Very Poor Metabolic Control: It Works and Is Safe!

被引:4
作者
Deepchand, Sonia [1 ]
Balla, Vanessa [1 ]
Eroukhmanoff, Juliette [1 ]
Sall, Khadijatou Ly [1 ]
Romain, Benedicte [1 ]
Lejeune, Marie [1 ]
Penfornis, Alfred [1 ,2 ]
Amadou, Coralie [1 ,2 ,3 ]
机构
[1] Sud Francilien Hosp, Diabet Dept, Corbeil Essonnes, France
[2] Paris Saclay Univ, Med Sch, Paris, France
[3] Sud Francilien Hosp, Diabet Dept, F-91190 Corbeil Essonnes, France
关键词
Closed-loop systems; Continuous glucose monitoring; Type; 1; diabetes; Poor metabolic control; GLYCEMIC CONTROL; RETINOPATHY;
D O I
10.1089/dia.2023.0379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the percentage of patients with type 1 diabetes (T1D) and very poor metabolic control who would agree to be treated with a hybrid closed-loop (HCL) insulin delivery system, and to assess metabolic improvement and safety. In a single center, we identified all patients aged >18 years with hemoglobin A1c (HbA1c) >11% (97 mmol/mol) before HCL treatment. We collected metabolic control and safety data up to 1 year post-HCL in those who accepted HCL after it was proposed to them. We identified 65 patients eligible for the study, 32 (50%) already used, or accepted to start using HCL. Patients were aged 18-49 years; mean(+/- standard deviation) baseline HbA1c was 12.5(+/- 1.8)% (113 +/- 20 mmol/mol). After 1 year, 25 patients (78%) were still using HCL and their mean HbA1c decreased to 9.4(+/- 1.9)% (79 mmol/mol) (P < 0.001). The rate of acute metabolic events was similar during the year of follow-up to the rate in the 3 years before HCL initiation. HCL systems should be considered in patients with T1D and very poor metabolic control.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 13 条
[1]   Long-term real-life glycaemic outcomes with a hybrid closed-loop system compared with sensor-augmented pump therapy in patients with type 1 diabetes [J].
Akturk, Halis Kaan ;
Giordano, Dominique ;
Champakanath, Anagha ;
Brackett, Scott ;
Garg, Satish ;
Snell-Bergeon, Janet .
DIABETES OBESITY & METABOLISM, 2020, 22 (04) :583-589
[2]   Diabeloop DBLG1 Closed-Loop System Enables Patients With Type 1 Diabetes to Significantly Improve Their Glycemic Control in Real-Life Situations Without Serious Adverse Events: 6-Month Follow-up [J].
Amadou, Coralie ;
Franc, Sylvia ;
Benhamou, Pierre-Yves ;
Lablanche, Sandrine ;
Huneker, Erik ;
Charpentier, Guillaume ;
Penfornis, Alfred .
DIABETES CARE, 2021, 44 (03) :844-846
[3]   6. Glycemic Targets: Standards of Medical Care in Diabetes-2022 [J].
American Diabetes Association Professional Practice Committee .
DIABETES CARE, 2022, 45 :S83-S96
[4]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[5]   Impact of Advanced Hybrid Closed Loop on Youth With High-Risk Type 1 Diabetes Using Multiple Daily Injections [J].
Boucsein, Alisa ;
Watson, Antony S. ;
Frewen, Carla M. ;
Sanders, Olivia J. ;
Haszard, Jillian J. ;
Jones, Shirley D. ;
Milford-Hughes, Philippa J. ;
de Bock, Martin I. ;
Wheeler, Benjamin J. .
DIABETES CARE, 2023, 46 (03) :628-632
[6]   One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology [J].
Breton, Marc D. ;
Kovatchev, Boris P. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (09) :601-608
[7]   Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users [J].
Da Silva, Julien ;
Lepore, Giuseppe ;
Battelino, Tadej ;
Arrieta, Arcelia ;
Castaneda, Javier ;
Grossman, Benyamin ;
Shin, John ;
Cohen, Ohad .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (02) :113-119
[8]   LONG-TERM GLYCEMIC CONTROL HAS A NONLINEAR ASSOCIATION TO THE FREQUENCY OF BACKGROUND RETINOPATHY IN ADOLESCENTS WITH DIABETES - FOLLOW-UP OF THE BERLIN RETINOPATHY STUDY [J].
DANNE, T ;
WEBER, B ;
HARTMANN, R ;
ENDERS, I ;
BURGER, W ;
HOVENER, G .
DIABETES CARE, 1994, 17 (12) :1390-1396
[9]   Early worsening of diabetic retinopathy after rapid improvement of blood glucose control in patients with diabetes [J].
Feldman-Billard, S. ;
Larger, E. ;
Massin, P. .
DIABETES & METABOLISM, 2018, 44 (01) :4-14
[10]   Real-World Evidence Supporting Tandem Control-IQ Hybrid Closed-Loop Success in the Medicare and Medicaid Type 1 and Type 2 Diabetes Populations [J].
Forlenza, Gregory P. ;
Carlson, Anders L. ;
Galindo, Rodolfo J. ;
Kruger, Davida F. ;
Levy, Carol J. ;
McGill, Janet B. ;
Umpierrez, Guillermo ;
Aleppo, Grazia .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (11) :814-823