Validation of a New Measuring Instrument for the Assessment of Bite Force

被引:4
作者
Nitschke, Ina [1 ,2 ]
Moede, Celine [1 ]
Hopfenmueller, Werner [3 ,4 ,5 ]
Sobotta, Bernhard A. J. [1 ]
Koenig, Andreas [6 ]
Jockusch, Julia [1 ,7 ]
机构
[1] Univ Leipzig, Dept Prosthet Dent & Mat Sci, Gerodontol Sect, Liebigstr 12, D-04103 Leipzig, Germany
[2] Univ Zurich, Ctr Dent Med, Clin Gen Special Care & Geriatr Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
[3] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, D-10117 Berlin, Germany
[4] Free Univ Berlin, Humboldt Univ Berlin, D-10117 Berlin, Germany
[5] Berlin Inst Hlth, D-10117 Berlin, Germany
[6] Univ Leipzig, Dept Prosthet Dent & Mat Sci, Mat Sci Sect, Liebigstr 12, D-04103 Leipzig, Germany
[7] Univ Zurich, Univ Res Prior Program Dynam Hlth Aging, CH-8050 Zurich, Switzerland
关键词
occlusal force; measuring device; prototype; measurement accuracy; chewing function; MASTICATORY PERFORMANCE; OCCLUSAL FORCE; QUANTITATIVE-EVALUATION; CHEWING EFFICIENCY; ABILITY; MUSCLE; SIZE; OVERDENTURES; ASSOCIATION; DENTURES;
D O I
10.3390/diagnostics13233498
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: this study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10 (R) (OFM) (Morita, Nagano Keiki, Higashimagome, Ohta-ku, Tokyo, Japan) and a prototype (PRO) by comparing them to a calibrated universal testing machine (ZWICK). Part 2 involved analyzing the devices' reliability based on clinical bite force measurements from study participants. Results: both devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO's intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups. Conclusion: both devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.
引用
收藏
页数:23
相关论文
共 58 条
[1]   Maximum occlusal bite forces in Jordanian individuals with different dentofacial vertical skeletal patterns [J].
Abu Alhaija, Elham S. J. ;
Al Zo'ubi, Ibraheem A. ;
Al Rousan, Mohammed E. ;
Hammad, Mohammad M. .
EUROPEAN JOURNAL OF ORTHODONTICS, 2010, 32 (01) :71-77
[2]   Maximum Bite Force following Unilateral Fixed Prosthetic Treatment: A Within-Subject Comparison to the Dentate Side [J].
Al-Zarea, Bader K. .
MEDICAL PRINCIPLES AND PRACTICE, 2015, 24 (02) :142-146
[3]  
Bakke M., 2006, SEMIN ORTHOD, V12, P120, DOI [DOI 10.1053/J.SODO.2006.01.005, 10.1053/j.sodo.2006.01.005]
[4]   Correlations between functional and occlusal tooth-surface areas and food texture during natural chewing sequences in humans [J].
Bourdiol, P ;
Mioche, L .
ARCHIVES OF ORAL BIOLOGY, 2000, 45 (08) :691-699
[5]   Improving masticatory performance, bite force, nutritional state and patient's satisfaction with implant overdentures: a systematic review of the literature [J].
Boven, G. C. ;
Raghoebar, G. M. ;
Vissink, A. ;
Meijer, H. J. A. .
JOURNAL OF ORAL REHABILITATION, 2015, 42 (03) :220-233
[6]  
BRAUN S, 1995, ANGLE ORTHOD, V65, P367
[7]   Individual mandibular movement registration and reproduction using an optoeletronic jaw movement analyzer and a dedicated robot: a dental technique [J].
Carossa, Massimo ;
Cavagnetto, Davide ;
Ceruti, Paola ;
Mussano, Federico ;
Carossa, Stefano .
BMC ORAL HEALTH, 2020, 20 (01)
[8]   Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser [J].
Chaturvedi, Saurabh ;
Addas, Mohamed Khaled ;
Alqahtani, Nasser M. ;
Al Ahmari, Nasser M. ;
Alfarsi, Mohammed A. .
TECHNOLOGY AND HEALTH CARE, 2021, 29 (04) :797-811
[9]   Novel System for Bite-Force Sensing and Monitoring Based on Magnetic Near Field Communication [J].
Diaz Lantada, Andres ;
Gonzalez Bris, Carlos ;
Lafont Morgado, Pilar ;
Sanz Maudes, Jesus .
SENSORS, 2012, 12 (09) :11544-11558
[10]   Novel Low-Cost Sensor for Human Bite Force Measurement [J].
Fastier-Wooller, Jarred ;
Hoang-Phuong Phan ;
Dinh, Toan ;
Tuan-Khoa Nguyen ;
Cameron, Andrew ;
Ochsner, Andreas ;
Dao, Dzung Viet .
SENSORS, 2016, 16 (08)