Experimental validation of the theoretical ejector model in a low-grade waste heat refrigeration system using R1233zdE as a working fluid

被引:7
|
作者
Mastrowski, Mikolaj [1 ,2 ]
Smolka, Jacek [3 ]
Butrymowicz, Dariusz [4 ]
Antczak, Lukasz [2 ]
Gagan, Jerzy [4 ]
Smierciew, Kamil [4 ]
机构
[1] Silesian Tech Univ, PhD Sch, Dept Thermal Technol, Akad 2a, PL-44100 Gliwice, Poland
[2] MARANI Ltd, Szybowa 14c, PL-41808 Zabrze, Poland
[3] Silesian Tech Univ, Dept Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
[4] Bialystok Tech Univ, Dept Thermal Engn, Wiejska 45c, PL-15351 Bialystok, Poland
关键词
Ejector; Refrigeration system; Waste heat; Low GWP refrigerant; Model validation; Experimental results; PERFORMANCE-CHARACTERISTICS; SUBCRITICAL OPERATION; GEOMETRY; DROP;
D O I
10.1016/j.applthermaleng.2023.121716
中图分类号
O414.1 [热力学];
学科分类号
摘要
Rising electricity prices and environmental regulations make it increasingly economically justifiable to utilize low-temperature waste heat, generated as a by-product of many technological processes. One potential application is the conversion of heat into cooling capacity using an ejector refrigeration system, to replace conventional electric-consuming cooling systems. Such systems, despite numerous descriptions in the literature, have not found industrial applications up to date. This work presents experimental results on the first commercial prototype cooling system driven by 200 kW waste heat of ultra-low temperature between 60 degrees C and 70 degrees C coming from the oil system of air compressors operating under real industrial operating conditions. A refrigeration system configuration based on the use of heat recovery downstream of the ejector and splitting the waste heat recovery heat exchanger into two stages was applied. The low GWP and low-pressure HFO R1233zd(E) refrigerant was used as a working fluid. The high-temperature cooling parameters, equivalent to the glycol temperature of 16 degrees C/19 degrees C (outlet/inlet of the evaporator), were examined and the COP of 0,25 was obtained. To obtain such a promising COP value, the critical and subcritical parameters of the ejector were investigated. Based on the experimental results the validation of the ejector theoretical model was performed for low-pressure refrigerant. The ejector component characteristic efficiencies were optimized for the ejector calculation model, and ejector key performance parameters were estimated to a high accuracy. The average relative error in the estimation was 7.1%, 4.5%, and 13.7% for the mass entrainment ratio, pressure ratio and ejector total efficiency, respectively. The resulting accuracy is sufficient from the perspective of refrigeration system design.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Investigation of a novel ejector expansion refrigeration system using the working fluid R134a and its potential substitute R1234yf
    Boumaraf, Latra
    Haberschill, Philippe
    Lallemand, Andre
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 45 : 148 - 159
  • [32] Energy Analysis and Working Fluid Selection of Combined ORC-VCC Refrigeration System Operated by Low-Grade Thermal Energy Sources
    Kumar, Rajnesh
    Memon, Abdul Ghafoor
    bin Tariq, Abdullah
    Yousfani, Faqeer Muhammad
    2021 4TH INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE 2021), 2021, : 133 - 138
  • [33] Parametric and working fluid analysis of a combined organic Rankine-vapor compression refrigeration system activated by low-grade thermal energy
    Saleh, B.
    JOURNAL OF ADVANCED RESEARCH, 2016, 7 (05) : 651 - 660
  • [34] Experimental study on a bifunctional heat utilization system of heat pump and power generation using low-grade heat source
    He, Zhonglu
    Zhang, Yufeng
    Wu, Zhangxiang
    Ma, Hongting
    Dong, Shengming
    APPLIED THERMAL ENGINEERING, 2017, 124 : 71 - 82
  • [35] Exergo-environmental analysis of nano fluid ORC low-grade waste heat recovery for hybrid trigeneration system
    Saadatfar, Bahram
    Fakhrai, Reza
    Fransson, Torsten
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 1879 - 1882
  • [36] Experimental investigation of a 250-kW turbine organic Rankine cycle system for low-grade waste heat recovery
    Fu, Ben-Ran
    Lee, Yuh-Ren
    Hsieh, Jui-Ching
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2016, 13 (14) : 1442 - 1450
  • [37] Theoretical study and design of a low-grade heat-driven pilot ejector refrigeration machine operating with butane and isobutane and intended for cooling of gas transported in a gas-main pipeline
    Petrenko, V. O.
    Volovyk, O. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1699 - 1706
  • [38] Experimental study on a small-scale pumpless organic Rankine cycle with R1233zd(E) as working fluid at low temperature heat source
    Lu, Huitong
    Wang, Zixuan
    Wang, Liwei
    Xu, Shengzhi
    Hu, Bin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (03) : 1203 - 1216
  • [39] Exergy Analysis and Advanced Exergy Analysis of a Novel Power/Refrigeration Cascade System for Recovering Low-Grade Waste Heat at 90-150° C
    Liu, Xiaobin
    Yu, Mengxiao
    Liu, Zhiqiang
    Yang, Sheng
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2022, 10 (28) : 9184 - 9193
  • [40] Energy, conventional and advanced exergy analysis for the organic Rankine cycle-vapor compression refrigeration combined system driven by low-grade waste heat
    Xia, Xiaoxia
    Liu, Zhipeng
    Wang, Zhiqi
    Zuo, Qingsong
    Sun, Tong
    APPLIED THERMAL ENGINEERING, 2023, 220