Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses

被引:10
作者
Baur, Isabella D. [1 ]
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ,2 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Heidelberg Univ, David J Apple Ctr Vis Res, Dept Ophthalmol, Heidelberg, Germany
[2] Heidelberg Univ, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
D O I
10.3928/1081597X-20230831-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc).METHODS: An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps. Area under the MTF and simulated visual acuity were calculated for different pupil diameters. Wavefront aberrations were measured with the SHS Ophthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor.RESULTS: All EDOF lenses yielded a simulated far visual acuity of 0.00 logMAR (20/20 Snellen) or better. At the 0.20 logMAR visual acuity level, the EDOF IOLs showed an increased depth of focus of at least 0.75 diopters compared to the monofocal IOL. Pupil dependency was more pronounced with the MiniWell, LuxSmart, and Vivity, whereas the Lentis showed a more consistent behavior at different apertures. The wavefront measurement revealed increased central aberrations for the MiniWell, LuxSmart, and Vivity IOL compared to the monofocal control.CONCLUSIONS: All EDOF IOLs demonstrated increased depth of focus while maintaining good simulated visual acuity at the far focus. Pupil dependency differed between the IOL models. The wavefront analysis revealed the complex design of the different EDOF IOLs with several zones with varying aberrations.
引用
收藏
页码:668 / 675
页数:8
相关论文
共 20 条
  • [1] Preclinical metrics to predict through-focus visual acuity for pseudophakic patients
    Alarcon, Aixa
    Canovas, Carmen
    Rosen, Robert
    Weeber, Henk
    Tsai, Linda
    Hileman, Kendra
    Piers, Patricia
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05): : 1877 - 1888
  • [2] Multifocal intraocular lenses: An overview
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Fernandez-Buenaga, Roberto
    Pikkel, Joseph
    Maldonado, Miguel
    [J]. SURVEY OF OPHTHALMOLOGY, 2017, 62 (05) : 611 - 634
  • [3] Extended depth-of-focus (EDOF) AcrySof® IQ Vivity® intraocular lens implant: a real-life experience
    Arrigo, Alessandro
    Gambaro, Gianpiera
    Fasce, Francesco
    Aragona, Emanuela
    Figini, Innocente
    Bandello, Francesco
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (09) : 2717 - 2722
  • [4] Multicountry clinical outcomes of a new nondiffractive presbyopia-correcting IOL
    Bala, Chandra
    Poyales, Francisco
    Guarro, Merce
    Ruiz Mesa, Ramon
    Mearza, Ali
    Varma, Devesh Kumar
    Jasti, Srichand
    Lemp-Hull, Jessie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02) : 136 - 143
  • [5] Visualization of Ray Propagation through Extended Depth-of-Focus Intraocular Lenses
    Baur, Isabella D.
    Auffarth, Gerd U.
    Yan, Weijia
    Labuz, Grzegorz
    Khoramnia, Ramin
    [J]. DIAGNOSTICS, 2022, 12 (11)
  • [6] A New Extended Depth of Focus Intraocular Lens Based on Spherical Aberration
    Bellucci, Roberto
    Curatolo, Maria C.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (06) : 389 - +
  • [7] Breyer DRH, 2017, ASIA-PAC J OPHTHALMO, V6, P339, DOI 10.22608/APO.2017186
  • [8] Preliminary Clinical Outcomes of a New Enhanced Depth of Focus Intraocular Lens
    Campos, Nuno
    Loureiro, Tomas
    Rodrigues-Barros, Sandra
    Carreira, Ana Rita
    Gouveia-Moraes, Filipe
    Carreira, Pedro
    Machado, Ines
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 4801 - 4807
  • [9] English D., 2000, (ISO 11979-2:1999). English version of DIN EN ISO 11979-2
  • [10] Functional results and photic phenomena with new extended-depth-of-focus intraocular Lens
    Giers, Bert C.
    Khoramnia, Ramin
    Varadi, Dorottya
    Wallek, Hannah
    Son, Hyeck-Soo
    Attia, Mary S.
    Auffarth, Gerd U.
    [J]. BMC OPHTHALMOLOGY, 2019, 19 (01)