On the measurement of radiation isocenter for medical accelerators using 3D polymer gel dosimetry. Introduction, application, and good practices

被引:7
|
作者
Kozicki, Marek [1 ,2 ]
Maras, Piotr [2 ,3 ]
机构
[1] Lodz Univ Technol, Fac Mat Technol & Text Design, Dept Mech Engn Informat & Chem Polymer Mat, PL-90543 Lodz, Poland
[2] GeVero Co, Lodz, Poland
[3] Copernicus Hosp, Dept Radiotherapy Planning, PL-93513 Lodz, Poland
关键词
Radiotherapy dosimetry; 3D dosimetry; Quality Assurance; polyGeVero-CT; Accelerators tests; IONIZING-RADIATION; QUALITY-ASSURANCE; RADIOSURGERY; VERIFICATION; ENHANCEMENT; SYSTEM;
D O I
10.1016/j.measurement.2023.113585
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work reviews the issue of determining the radiation isocenter for quality assurance tests of medical accelerators. High resolution 3D polymer gel dosimetry is employed, which is composed of a polymer gel dosimeter, iterative cone-beam computed tomography and a dedicated software package. Among the approaches for the determination of radiation isocenter, the centroid does not always produce a good result and a gradientbased optimization method is the slowest, however produces the same results as an analytical solution for the smallest intersecting circle. A protocol of using the 3D dosimetry for the radiation isocenter determination is presented, which includes the preparation and handling of the 3D dosimeter, star-shot irradiation with 10,000 MU per each of four beams of a medical accelerator following by immediate 3D scanning (Pelvis mode) and data processing (averaging signal, background subtraction). Uncertainty budget points to 1.3 mm spatial uncertainty. Potential problems when determining the radiation isocenter are discussed.
引用
收藏
页数:12
相关论文
共 27 条
  • [1] Measurement of the radiation dose and radiation isocenter of the TrueBeam accelerator using 3D polymer gel dosimeters from the VIPAR family with different chemical history
    Kozicki, M.
    Jaszczak, M.
    Maras, P.
    Kadlubowski, S.
    MEASUREMENT, 2023, 221
  • [2] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35
  • [3] Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
    Maras, Piotr
    Kozicki, Marek
    MATERIALS, 2022, 15 (19)
  • [4] Optical Scanner for 3D Radiotherapy Polymer Gel Dosimetry
    Sobotka, P.
    Kozicki, M.
    Maras, P.
    Boniecki, L.
    Kacperski, K.
    Domanski, A. W.
    ACTA PHYSICA POLONICA A, 2012, 122 (05) : 969 - 974
  • [5] Feasibility Study of Polymer Gel Dosimetry Using a 3D Printed Phantom for Liver Cancer Radiotherapy
    Minsik Lee
    Seonyeong Noh
    KyoungJun Yoon
    Sang-Wook Lee
    Sang Min Yoon
    Jinhong Jung
    Chiyoung Jeong
    Jungwon Kwak
    Journal of the Korean Physical Society, 2020, 76 : 453 - 457
  • [6] Feasibility Study of Polymer Gel Dosimetry Using a 3D Printed Phantom for Liver Cancer Radiotherapy
    Lee, Minsik
    Noh, Seonyeong
    Yoon, KyoungJun
    Lee, Sang-Wook
    Yoon, Sang Min
    Jung, Jinhong
    Jeong, Chiyoung
    Kwak, Jungwon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (06) : 453 - 457
  • [7] Application of a linear interpolation algorithm in radiation therapy dosimetry for 3D dose point acquisition
    Guo, Yixiao
    Li, Bo
    Li, Yazhou
    Du, Wen
    Feng, Weigui
    Feng, Shifang
    Miao, Guoying
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [8] New normoxic N-(Hydroxymethyl)acrylamide based polymer gel for 3D dosimetry in radiation therapy
    Rabaeh, Khalid A.
    Basfar, Ahmed A.
    Almousa, Akram A.
    Devic, Slobodan
    Moftah, Belal
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 121 - 126
  • [9] On the validity of 3D polymer gel dosimetry: I. Reproducibility study
    Vandecasteele, Jan
    De Deene, Yves
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01): : 19 - 42
  • [10] TTC-Pluronic 3D radiochromic gel dosimetry of ionizing radiation
    Kozicki, Marek
    Kwiatos, Klaudia
    Kadlubowski, Slawomir
    Dudek, Mariusz
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14): : 5668 - 5690