Parameters optimization and trajectory planning of a novel 3-UPU parallel mechanism for ankle rehabilitation

被引:2
作者
Chen, Xuechan [1 ,2 ]
Guo, Yu [1 ,2 ]
Xin, Chao [1 ,2 ]
Ji, Chaoyang [1 ,2 ]
Fan, Jianxun [1 ,2 ]
Chen, Ziming [1 ,2 ]
机构
[1] Yanshan Univ, Sch Mech Engn, Qinhuangdao, Hebei, Peoples R China
[2] Yanshan Univ, Parallel Robot & Mechatron Syst Lab Hebei Prov, Qinhuangdao, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
ankle rehabilitation; parallel mechanism; kinematic analysis; optimization of parameters; trajectory planning; ROBOT; KINEMATICS; MOBILITY; COMPLEX; DESIGN; JOINTS; AXIS;
D O I
10.1017/S0263574723000711
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Ankle rehabilitation robots are widely used due to nerve injuries and sports injuries leading to decreased mobility of the ankle joint. However, the motion of most ankle rehabilitation robots has distinctions with human ankle physiological structure. In order to achieve more accurate rehabilitation training of the ankle joint, this paper proposes a novel 3-UPU parallel rehabilitation mechanism. In a certain range, the mechanism can perform rotation around any axis within the midplane, which means that the mechanism can achieve non-fixed-point rotation around the instantaneous axis of the ankle joint. The mechanism has three degrees of freedom and can perform ankle pronation/supination and inversion/eversion movements. Taking into account the structural differences of different human bodies, the rotating axis of the mechanism can be adjusted in both height and angle. Then, the workspace of the mechanism was solved, and the size parameters of the mechanism are analyzed based on the characteristics of the size parameters of the mechanism and the motion range of the ankle. A genetic algorithm was employed to optimize the mechanism's parameters. Next, the motion trajectory of the mechanism was planned, and the length change of the mechanism driving pair during the motion planning of the angle was obtained through kinematics simulation. Finally, experimental verification of the above rehabilitation training methods indicates that the mechanism meets the requirements of ankle rehabilitation.
引用
收藏
页码:3235 / 3251
页数:17
相关论文
共 41 条
  • [1] Design of a novel two degree-of-freedom ankle-foot orthosis
    Agrawal, Abhishek
    Sangwan, Vivek
    Banala, Sai K.
    Agrawal, Sunil K.
    Binder-Macleod, Stuart A.
    [J]. JOURNAL OF MECHANICAL DESIGN, 2007, 129 (11) : 1137 - 1143
  • [2] Robot-assisted ankle rehabilitation: a review
    Alvarez-Perez, Marian G.
    Garcia-Murillo, Mario A.
    Jesus Cervantes-Sanchez, J.
    [J]. DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2020, 15 (04) : 394 - 408
  • [3] BARNETT CH, 1952, J ANAT, V86, P1
  • [4] Ortega AB, 2013, REV FAC ING-UNIV ANT, P183
  • [5] Articulated external fixation of the ankle: minimizing motion resistance by accurate axis alignment
    Bottlang, M
    Marsh, JL
    Brown, TD
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (01) : 63 - 70
  • [6] Carney D. D., 2023, FOOT ANKLE ORTHOP, V8, p24730114221151080
  • [7] Kinematics and reliable analysis of decoupled parallel mechanism for ankle rehabilitation
    Chang, Ting-Cheng
    Zhang, Xiao-Dong
    [J]. MICROELECTRONICS RELIABILITY, 2019, 99 : 203 - 212
  • [8] FORCE/POSITION CONTROL STRATEGY OF 3-PRS ANKLE REHABILITATION ROBOT
    Chen, Guoqiang
    Zhou, Hongpeng
    Yang, Pengcheng
    [J]. INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2020, 16 (02): : 481 - 494
  • [9] Chen Z., DISABIL REHABIL ASSI, V41, P1
  • [10] Symmetrical 2R1T parallel mechanism without parasitic motion
    Chen Z.
    Zhang Y.
    Huang K.
    Huang Z.
    [J]. Chen, Ziming (chenzm@ysu.edu.cn), 1600, Chinese Mechanical Engineering Society (52): : 9 - 17