A method for sizing air source heat pump considering the joint effect of outdoor air temperature and relative humidity

被引:38
作者
Li, Zhaoyang [1 ]
Wei, Wenzhe [1 ]
Wang, Wei [1 ,2 ]
Sun, Yuying [1 ]
Wang, Shiquan [1 ]
Lin, Yao [1 ]
Huang, Chengyang [1 ]
Wu, Yong [1 ]
Deng, Shiming [3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
[2] Beijing Inst Petrochem Technol, Sch Safety Engn, Beijing 102627, Peoples R China
[3] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 65卷
基金
中国博士后科学基金;
关键词
Air source heat pump; Frosting; Sizing method; Output heating capacity; Capacity design correction factor; TECHNOECONOMIC ANALYSIS; PERFORMANCE; DESIGN; OPTIMIZATION; PREDICTION; SYSTEMS; INDEX;
D O I
10.1016/j.jobe.2022.105815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
When operated in a highly humid environment, frost may accumulate on the surface of the outdoor coil in air source heat pump units (ASHPs), leading to a reduction in its output heating capacity. Currently, the existing methods for sizing ASHPs only considered the effect of outdoor air temperature, Ta, without taking into account the effect of relative humidity, RH, on output heating capacity. This often resulted in an insufficient heating capacity from an ASHP selected. To resolve this issue, a model for predicting the output heating capacity of ASHPs, Qh, was estab-lished firstly. Then, considering the variation in the rated output heating capacity of ASHPs, a method for sizing ASHPs considering the joint effect of Ta and RH has been developed. Besides, for practical application, a capacity design correction factor, K, was proposed, evaluated, and plotted as a cloud picture. Evaluating results indicated that K can be used for sizing ASHPs accurately. When the effect of frosting on Qh was considered, the maximum rates of decrease in the output heating capacity correction factor, KQ, was between 43.8% and 50.0%, and the outdoor air design temperatures for space heating in six typical Chinese cities were decreased by 1.8-3.5 degrees C, with the average of 2.8 degrees C. For highly humid cities, such as Qiannan area China, even if its outdoor air design temperature was 1.4 degrees C higher than that in Chongqing City, the K value was 0.24 lower.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Control strategy and experimental study on a novel defrosting method for air-source heat pump
    Liang, Cai-Hua
    Zhang, Xiao-Song
    Li, Xiu-Wei
    Chen, Zhen-Qian
    APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 892 - 899
  • [42] Dynamic characteristics of refrigerant evaporation temperature in air-water heat source heat pump
    Tan, Xin
    Long, Jibo
    Li, Jinhua
    Li, Zhongwen
    Jiang, Hanyu
    Liu, Hang
    APPLIED THERMAL ENGINEERING, 2024, 247
  • [43] An advanced exhausting airflow photovoltaic curtain wall system coupled with an air source heat pump for outdoor air treatment: Energy-saving performance assessment
    Tang, Yayun
    Ji, Jie
    Zhang, Chengyan
    Ke, Wei
    Xie, Hao
    ENERGY CONVERSION AND MANAGEMENT, 2024, 299
  • [44] A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load
    Wei, Wenzhe
    Ni, Long
    Li, Shuyi
    Wang, Wei
    Yao, Yang
    Xu, Laifu
    Yang, Yahua
    RENEWABLE ENERGY, 2020, 161 : 184 - 199
  • [45] ENERGY AND EXERGY ANALYSIS OF AN AIR SOURCE HEAT PUMP UNDER VARIABLE AMBIENT CONDITIONS
    Streckiene, Giedre
    Kropas, Tomas
    Mikucioniene, Ruta
    Dziugaite-Tumeniene, Rasa
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2024, 32 (01) : 12 - 21
  • [46] A data-driven evaluating method on the defrosting effect of the air source heat pump system in Beijing
    Guo, Yanhua
    Shao, Shuangquan
    Geng, Xudong
    Li, Hao
    Wang, Zhichao
    Akkurt, Nevzat
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [47] Solar-assisted temperature vacuum swing adsorption for direct air capture: Effect of relative humidity
    Ji, Y.
    Liu, W.
    Yong, J. Y.
    Zhang, X. J.
    Jiang, L.
    APPLIED ENERGY, 2023, 348
  • [48] The effectiveness of vapor-injection for an inverter air-source heat pump compared with vapor-return
    Wang, Jijin
    Guo, Jianxiang
    Qv, Dehu
    Zhang, Linyang
    Liu, Na
    Ni, Long
    APPLIED THERMAL ENGINEERING, 2024, 245
  • [49] Impact of relative humidity, temperature difference, and surface type on humid air condensation heat transfer
    Dehghani, Parisa
    Ahmadi, Hesam Ami
    Hosseinalipour, Seyed Mostafa
    Akbari, Habibollah
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 203
  • [50] Controlling Temperature and Relative Humidity of Ventilation Air by using a Cooling Coil and Rotary Heat Exchangers
    Ibrahim, Furugaan
    Chirarattananon, Surapong
    Rakkwamsuk, Pattana
    Chaiwiwatworakul, Pipat
    Chuangchote, Surawut
    Hien, Vu Duc
    INTERNATIONAL ENERGY JOURNAL, 2021, 21 (03): : 401 - 414