A method for sizing air source heat pump considering the joint effect of outdoor air temperature and relative humidity

被引:38
作者
Li, Zhaoyang [1 ]
Wei, Wenzhe [1 ]
Wang, Wei [1 ,2 ]
Sun, Yuying [1 ]
Wang, Shiquan [1 ]
Lin, Yao [1 ]
Huang, Chengyang [1 ]
Wu, Yong [1 ]
Deng, Shiming [3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
[2] Beijing Inst Petrochem Technol, Sch Safety Engn, Beijing 102627, Peoples R China
[3] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 65卷
基金
中国博士后科学基金;
关键词
Air source heat pump; Frosting; Sizing method; Output heating capacity; Capacity design correction factor; TECHNOECONOMIC ANALYSIS; PERFORMANCE; DESIGN; OPTIMIZATION; PREDICTION; SYSTEMS; INDEX;
D O I
10.1016/j.jobe.2022.105815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
When operated in a highly humid environment, frost may accumulate on the surface of the outdoor coil in air source heat pump units (ASHPs), leading to a reduction in its output heating capacity. Currently, the existing methods for sizing ASHPs only considered the effect of outdoor air temperature, Ta, without taking into account the effect of relative humidity, RH, on output heating capacity. This often resulted in an insufficient heating capacity from an ASHP selected. To resolve this issue, a model for predicting the output heating capacity of ASHPs, Qh, was estab-lished firstly. Then, considering the variation in the rated output heating capacity of ASHPs, a method for sizing ASHPs considering the joint effect of Ta and RH has been developed. Besides, for practical application, a capacity design correction factor, K, was proposed, evaluated, and plotted as a cloud picture. Evaluating results indicated that K can be used for sizing ASHPs accurately. When the effect of frosting on Qh was considered, the maximum rates of decrease in the output heating capacity correction factor, KQ, was between 43.8% and 50.0%, and the outdoor air design temperatures for space heating in six typical Chinese cities were decreased by 1.8-3.5 degrees C, with the average of 2.8 degrees C. For highly humid cities, such as Qiannan area China, even if its outdoor air design temperature was 1.4 degrees C higher than that in Chongqing City, the K value was 0.24 lower.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Prediction of evaporation temperature in air-water heat source heat pump based on artificial neural network
    Li, Chuanming
    Li, Nianping
    Tan, Xin
    Yongga, A.
    Long, Jibo
    Shen, Xiaohang
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [32] Experimental investigation on a screw-type air source heat pump system with air heat absorption defrosting
    Jia, Jikang
    Si, Pengfei
    Rong, Xiangyang
    Liu, Boran
    Xiang, Bo
    Shi, Lijun
    Zhang, Min
    APPLIED THERMAL ENGINEERING, 2024, 241
  • [33] Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump
    Yu, X.
    Wang, R. Z.
    Zhai, X. Q.
    ENERGY, 2011, 36 (02) : 1309 - 1318
  • [34] Analysis of a dual-temperature air source heat pump cycle with an ejector
    Wang, Min
    Cheng, Yue
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2021, 193
  • [35] Optimization method for multiple heat source operation including ground source heat pump considering dynamic variation in ground temperature
    Ikeda, Shintaro
    Choi, Wonjun
    Ooka, Ryozo
    APPLIED ENERGY, 2017, 193 : 466 - 478
  • [36] Experimental study on hot liquid subcooling defrosting of an air source heat pump with multi-connected outdoor units
    Ma, Guoyuan
    Lu, Tianyu
    Liu, Fusheng
    Niu, Jianhui
    Xu, Shuxue
    ENERGY AND BUILDINGS, 2023, 291
  • [37] Experimental investigation of an air source heat pump with multigroup heat pipe radiators
    Xu, Shuxue
    Niu, Jianhui
    Ma, Guoyuan
    SOLAR ENERGY, 2023, 260 : 137 - 146
  • [38] A visual defrosting control method for air source heat pump system based on machine vision
    Zhao, Han
    Liu, Zihan
    Sang, Yufeng
    Chang, Junzhi
    Zheng, Xuejing
    Jurasz, Jakub
    Zheng, Wandong
    ENERGY, 2024, 302
  • [39] The variable water temperature control strategy of the air-source heat pump compatible with floor heating system for an apartment
    Liu, Yanrong
    Nan, Xiaohong
    Han, Han
    Li, Jie
    JOURNAL OF BUILDING ENGINEERING, 2024, 90
  • [40] Experimental study on heat storage air source heat pump system with"no frost effect"
    Zhao H.
    Yu S.
    Qiu G.
    Shen C.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (04): : 61 - 67