A method for sizing air source heat pump considering the joint effect of outdoor air temperature and relative humidity

被引:38
作者
Li, Zhaoyang [1 ]
Wei, Wenzhe [1 ]
Wang, Wei [1 ,2 ]
Sun, Yuying [1 ]
Wang, Shiquan [1 ]
Lin, Yao [1 ]
Huang, Chengyang [1 ]
Wu, Yong [1 ]
Deng, Shiming [3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
[2] Beijing Inst Petrochem Technol, Sch Safety Engn, Beijing 102627, Peoples R China
[3] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 65卷
基金
中国博士后科学基金;
关键词
Air source heat pump; Frosting; Sizing method; Output heating capacity; Capacity design correction factor; TECHNOECONOMIC ANALYSIS; PERFORMANCE; DESIGN; OPTIMIZATION; PREDICTION; SYSTEMS; INDEX;
D O I
10.1016/j.jobe.2022.105815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
When operated in a highly humid environment, frost may accumulate on the surface of the outdoor coil in air source heat pump units (ASHPs), leading to a reduction in its output heating capacity. Currently, the existing methods for sizing ASHPs only considered the effect of outdoor air temperature, Ta, without taking into account the effect of relative humidity, RH, on output heating capacity. This often resulted in an insufficient heating capacity from an ASHP selected. To resolve this issue, a model for predicting the output heating capacity of ASHPs, Qh, was estab-lished firstly. Then, considering the variation in the rated output heating capacity of ASHPs, a method for sizing ASHPs considering the joint effect of Ta and RH has been developed. Besides, for practical application, a capacity design correction factor, K, was proposed, evaluated, and plotted as a cloud picture. Evaluating results indicated that K can be used for sizing ASHPs accurately. When the effect of frosting on Qh was considered, the maximum rates of decrease in the output heating capacity correction factor, KQ, was between 43.8% and 50.0%, and the outdoor air design temperatures for space heating in six typical Chinese cities were decreased by 1.8-3.5 degrees C, with the average of 2.8 degrees C. For highly humid cities, such as Qiannan area China, even if its outdoor air design temperature was 1.4 degrees C higher than that in Chongqing City, the K value was 0.24 lower.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A method for sizing air source heat pump and electric boiler considering the peak and valley electricity prices
    Zhang, Haotian
    Zhang, Xiaoming
    Wang, Qiang
    Ma, Yinghan
    Zhao, Shiyu
    Wang, Chenzheng
    Chen, Qili
    Wang, Xinwei
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [2] Performance analysis of air source heat pump according to outside temperature and relative humidity with mathematical modeling
    Sezen, Kutbay
    Gungor, Afsin
    ENERGY CONVERSION AND MANAGEMENT, 2022, 263
  • [3] Operation Parameters Variation of Air Source Heat Pump According to the Outdoor Temperature
    Sezen, Kutbay
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (03): : 1179 - 1184
  • [4] The frost restraining effect of solar air collector applied to air source heat pump
    Jiang, Yan
    Pu, Jiaxuan
    Zhang, Huan
    Liu, Sujie
    Wang, Yaran
    You, Shijun
    Wan, Zhihao
    Wu, Zhangxiang
    Fan, Xianwang
    Liu, Zhikai
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [5] Inversion Method for Optimizing the Condensing Heat Recovery System of an Air-Source Heat Pump
    Su, Huan
    Gong, Guangcai
    Zhang, Yunzhi
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (04)
  • [6] A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit
    Bai, Xiaoxia
    Liu, Shengnan
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [7] Dynamic defrosting characteristics of air source heat pump and effects of outdoor air parameters on defrost cycle performance
    Chen, Yi-guang
    Guo, Xian-min
    APPLIED THERMAL ENGINEERING, 2009, 29 (13) : 2701 - 2707
  • [8] Impact of ambient temperature and humidity on the performance of a novel anti-frosting air source heat pump system
    Lyu, Ning
    Feng, Guozeng
    He, Hui
    Liang, Caihua
    Zhang, Xiaosong
    Wang, Feng
    Zhu, Minqiang
    ENERGY, 2025, 314
  • [9] Evaluation of the coefficient of performance of an air source heat pump unit and an air to water heat pump
    Tangwe, S.
    Kusakana, K.
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2021, 32 (01) : 27 - 40
  • [10] A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
    Long, Zhang
    Dong Jiankai
    Jiang Yiqiang
    Yang, Yao
    APPLIED ENERGY, 2014, 133 : 101 - 111