A Novel Portable Unilateral Magnetic Resonance Magnet for Noninvasive Quantification of Human Liver Fat

被引:0
|
作者
Lu, Rongsheng [1 ]
Jiang, Xiaowen [1 ]
Zhang, Jinxiang [1 ]
Hu, Jianxiong [2 ]
Chen, Xiao [2 ]
Wu, Ziyue [2 ]
Qian, Zhiyong
Luo, Hai [2 ]
Ni, Zhonghua [1 ]
Yi, Hong [1 ]
机构
[1] Southeast Univ, Sch Mech Engn, Jiangsu Key Lab Design & Manufacture Micronano Bio, Nanjing 211189, Peoples R China
[2] Wuxi Marvel Stone Healthcare Co Ltd, Wuxi 214000, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; Fats; Nuclear magnetic resonance; Magnetic fields; Magnetic field measurement; Liver diseases; Radio frequency; Liver fat quantification; magnetic resonance; noninvasive measurement; relaxometry; single-sided magnet; DISEASE; CONNECTIONS; ULTRASOUND; STEATOSIS; OBESITY;
D O I
10.1109/TIM.2023.3268480
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fatty liver disease has become one of the common liver diseases seriously affecting people's health and quality of life. Existing means to quantify liver fat content are usually invasive and high-cost. Our research aims to design a single-sided magnet to develop a low-cost, noninvasive, and lightweight unilateral magnetic resonance (UMR) system that can satisfy the needs for fatty liver screening and diagnosis. A novel single-sided permanent magnet with a pear-shaped magnetic field iso-surface was designed to avoid the excitation of subcutaneous tissue in the human body. The weight of the magnet was optimized to 12.9 kg, and the mean magnetic field strength of the region of interest (ROI) was 0.07 T. The radio frequency (RF) coil set, the pulse sequence, and the modeling method for measuring proton density fat fraction (PDFF) were also introduced. Experiments for phantoms and volunteers were carried out by the UMR system to verify the performance of detection. The phantom detection results show that the UMR system can effectively avoid the influence of the subcutaneous tissue part on PDFF detection, with reasonable accuracy (around 5% fat fraction error) and robustness (within 10% relative error). Compared with a conventional magnetic resonance imaging (MRI) scanner, measurement results of volunteers (around 3% fat fraction error) show the effectiveness of the UMR system for screening fatty liver diseases. The UMR system developed based on the proposed portable single-sided magnet could be a low-cost and reliable diagnostic tool for noninvasive fatty liver disease diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantification of liver fat infiltration by magnetic resonance
    Herrera, Rodrigo
    Penaloza, Francisco
    Arrietal, Cristobal
    Zacconi, Flavia
    Saavedra, Victor
    Saavedra, Carla
    Branes, Cecilia
    Hack, Thomas
    Uribe, Sergio
    REVISTA MEDICA DE CHILE, 2019, 147 (07) : 821 - 827
  • [2] Radiofrequency coil design for improving human liver fat quantification in a portable single-side magnetic resonance system
    Yang, Shiwei
    Chen, Xiao
    Chen, Suen
    Chen, Hao
    Zhao, Yue
    Wu, Ziyue
    Luo, Hai
    Zhang, Zhiyong
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [3] Quantification of Liver Fat with Magnetic Resonance Imaging
    Reeder, Scott B.
    Sirlin, Claude B.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 337 - +
  • [4] Magnetic Resonance Imaging Quantification of Liver Iron
    Sirlin, Claude B.
    Reeder, Scott B.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 359 - +
  • [5] Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification
    Hamilton, Gavin
    Middleton, Michael S.
    Bydder, Mark
    Yokoo, Takeshi
    Schwimmer, Jeffrey B.
    Kono, Yuko
    Patton, Heather M.
    Lavine, Joel E.
    Sirlin, Claude B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 145 - 152
  • [6] Performing Quality Control on Magnetic Resonance Imaging Liver Fat/Iron Quantification Studies: A Critical Requirement
    Hajibonabi, Farid
    Sharma, Puneet
    Davarpanah, Amir H.
    Balthazar, Patricia
    Moreno, Courtney C.
    Pectasides, Melina
    Nandwana, Sadhna B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (05) : 689 - 697
  • [7] Utility of magnetic resonance proton density fat fraction technique in quantification of liver fat in living donors for liver transplantation
    Sherif, Fatma Mohamed
    Elmogy, Sabry Alameldeen
    Abd EL-wahab, Rihame Mohamed
    Wahab, Mohamed Abdel
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01)
  • [8] Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design
    Paulsen, Jeffrey L.
    Franck, John
    Demas, Vasiliki
    Bouchard, Louis-S.
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (12) : 4582 - 4590
  • [9] Proton magnetic resonance spectroscopy and ultrasound for hepatic fat quantification
    Mehta, Sanjeev R.
    Thomas, Elizabeth Louise
    Patel, Nayna
    Crofton, Mary E.
    McCarthy, John
    Eliahoo, Joseph
    Morin, Stanislas X.
    Fitzpatrick, Julie
    Durighel, Giuliana
    Goldstone, Anthony P.
    Johnston, Desmond G.
    Bell, Jimmy D.
    Taylor-Robinson, Simon D.
    HEPATOLOGY RESEARCH, 2010, 40 (04) : 399 - 406
  • [10] Noninvasive depth profiling of walls by portable nuclear magnetic resonance
    Bluemich, Bernhard
    Haber, Agnes
    Casanova, Federico
    Del Federico, Eleonora
    Boardman, Victoria
    Wahl, Gerhard
    Stilliano, Antonella
    Isolani, Licio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (07) : 3117 - 3125