Ultra-high field MRI: parallel-transmit arrays and RF pulse design

被引:22
作者
Williams, Sydney N. [1 ]
McElhinney, Paul [1 ]
Gunamony, Shajan [1 ,2 ]
机构
[1] Univ Glasgow, Imaging Ctr Excellence, Glasgow, Scotland
[2] MR CoilTech Ltd, Glasgow, Scotland
基金
“创新英国”项目;
关键词
radiofrequency (RF) coils; ultra-high field (UHF) magnetic resonance imaging (MRI); parallel transmission (pTx); electromagnetic (EM) fields; specific absorption rate (SAR); TO-NOISE RATIO; CERVICAL-SPINAL CORD; RATE INTERSUBJECT VARIABILITY; LEAST-SQUARES OPTIMIZATION; INNER-VOLUME EXCITATIONS; ABSORPTION RATE; HIGH-RESOLUTION; HUMAN BRAIN; COIL ARRAY; RADIOFREQUENCY COIL;
D O I
10.1088/1361-6560/aca4b7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper reviews the field of multiple or parallel radiofrequency (RF) transmission for magnetic resonance imaging (MRI). Currently the use of ultra-high field (UHF) MRI at 7 tesla and above is gaining popularity, yet faces challenges with non-uniformity of the RF field and higher RF power deposition. Since its introduction in the early 2000s, parallel transmission (pTx) has been recognized as a powerful tool for accelerating spatially selective RF pulses and combating the challenges associated with RF inhomogeneity at UHF. We provide a survey of the types of dedicated RF coils used commonly for pTx and the important modeling of the coil behavior by electromagnetic (EM) field simulations. We also discuss the additional safety considerations involved with pTx such as the specific absorption rate (SAR) and how to manage them. We then describe the application of pTx with RF pulse design, including a practical guide to popular methods. Finally, we conclude with a description of the current and future prospects for pTx, particularly its potential for routine clinical use.
引用
收藏
页数:32
相关论文
共 266 条
  • [1] MAPPING OF METABOLITES IN WHOLE ANIMALS BY P-31 NMR USING SURFACE COILS
    ACKERMAN, JJH
    GROVE, TH
    WONG, GG
    GADIAN, DG
    RADDA, GK
    [J]. NATURE, 1980, 283 (5743) : 167 - 170
  • [2] Transmit and receive transmission line arrays for 7 tesla parallel imaging
    Adriany, G
    Van de Moortele, PF
    Wiesinger, F
    Moeller, S
    Strupp, JP
    Andersen, P
    Snyder, C
    Zhang, XL
    Chen, W
    Pruessmann, KP
    Boesiger, P
    Vaughan, T
    Ugurbil, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 434 - 445
  • [3] A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    Adriany, Gregor
    De Moortele, Pierre-Francois Van
    Ritter, Johannes
    Moeller, Steen
    Auerbach, Edward J.
    Akguen, Can
    Snyder, Carl J.
    Vaughan, Thomas
    Ugurbill, Kamil
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 590 - 597
  • [4] Adriany G, 2019, PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), P1171, DOI [10.1109/ICEAA.2019.8879131, 10.1109/iceaa.2019.8879131]
  • [5] A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla
    Adriany, Gregor
    Auerbach, Edward J.
    Snyder, Carl J.
    Gozubuyuk, Ark
    Moeller, Steen
    Ritter, Johannes
    Van de Moortele, Pierre-Francois
    Vaughan, Tommy
    Ugurbil, Kamil
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1478 - 1485
  • [6] Time optimal control-based RF pulse design under gradient imperfections
    Aigner, Christoph S.
    Rund, Armin
    Seada, Samy Abo
    Price, Anthony N.
    Hajnal, Joseph, V
    Malik, Shaihan J.
    Kunisch, Karl
    Stollberger, Rudolf
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 561 - 574
  • [7] Calibration-free pTx of the human heart at 7T via 3D universal pulses
    Aigner, Christoph Stefan
    Dietrich, Sebastian
    Schaeffter, Tobias
    Schmitter, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 70 - 84
  • [8] Ajanovic A., 2020, P 28 ANN M ISMRM, P4251
  • [9] [Anonymous], 2017, FDA CLEARS 1 7T MAGN
  • [10] [Anonymous], 2020, FDA CLEARS MOST POW