Free-breathing simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) with isotropic resolution using 3D golden-angle radial trajectory

被引:6
作者
Wang, Yajie [1 ]
Qi, Haikun [2 ]
Wang, Yishi [3 ]
Xiao, Ming [4 ,5 ]
Xiang, Canhong [5 ]
Dong, Jiahong [5 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
[3] Philips Healthcare, Beijing, Peoples R China
[4] Shandong Univ, Dept Hepatobiliary Surg, Hosp 2, Jinan, Peoples R China
[5] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Hepatopancreato Biliary Ctr, Sch Clin Med, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Water-fat separation; fat fraction (FF); T1; mapping; liver; INVERSION-RECOVERY MOLLI; QUANTIFICATION; T-1; PROTON; RECONSTRUCTION; MRI;
D O I
10.21037/qims-22-748
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional liver T1 mapping techniques are typically performed under breath-holding conditions; they have limited slice coverage and often rely on multiple acquisitions. Furthermore, liver fat affects the accuracy of T1 quantification. Therefore, we aim to propose a free-breathing technique for simultaneous water-fat separation and T1 mapping of the whole liver (SWALI) in a single scan.Methods: The proposed SWALI sequence included an inversion recovery (IR) preparation pulse followed by a series of multiecho three-dimensional (3D) golden-angle radial acquisitions. For each echo time (TE), a series of images containing a mix of water and fat were reconstructed using a sliding window method. For each inversion time (TI), water and fat were separated, and then water and fat T1 estimation was conducted. The fat fraction (FF) was calculated based on the last TI image. The FF and water T1 quantification accuracy were compared with the gold standard sequences in the phantom. The in vivo feasibility was tested in 9 healthy volunteers, 2 patients with fatty liver, and 3 patients with hepatocellular carcinoma (HCC). The reproducibility was evaluated in the patients with fatty liver and in the healthy volunteers.Results: The mean FF and the mean water T1 values obtained by the SWALI sequence showed good agreements with chemical shift-encoded magnetic resonance imaging (CSE-MRI; r=0.998; P<0.001) and fat-suppressed (FS) IR-spin echo (SE; r=0.997; P<0.001) in the phantom. For the patients with fatty liver and the healthy volunteers, the SWALI sequence showed no significant difference with CSE-MRI in FF quantification (P=0.53). In T1 quantification, comparable T1 values were obtained with the SWALI sequence and modified Look-Locker inversion recovery (MOLLI; P=0.10) in healthy volunteers, while the water T1 estimated by the SWALI sequence was significantly lower than the water-fat compound T1 estimated by MOLLI (P<0.001) in patients with fatty liver. In the reproducibility study, the intraclass correlation coefficients (ICCs) for the estimated FF and water T1 were 0.997 and 0.943, respectively. Water T1 of the patients with HCC calculated using the SWALI sequence showed a significant reduction after the contrast administration (P<0.001). Conclusions: Free-breathing water-fat separation and T1 mapping of the whole liver with 2.5 mm isotropic spatial resolution were achieved simultaneously using the SWALI sequence in a 5-min scan.
引用
收藏
页码:912 / 923
页数:12
相关论文
共 27 条
  • [21] Free-breathing high isotropic resolution quantitative susceptibility mapping (QSM) of liver using 3D multi-echo UTE cones acquisition and respiratory motion-resolved image reconstruction
    Kang, MungSoo
    Behr, Gerald G.
    Jafari, Ramin
    Gambarin, Maya
    Otazo, Ricardo
    Kee, Youngwook
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 1844 - 1858
  • [22] Free-breathing dynamic T1WI using compressed sensing-golden angle radial sparse parallel imaging for liver MRI in patients with limited breath-holding capability
    Park, Jin Young
    Lee, Sang Min
    Lee, Jeong Sub
    Chang, Won
    Yoon, Jeong Hee
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 152
  • [23] Simultaneous proton density, T1, T2, and flip-angle mapping of the brain at 7 T using multiparametric 3D SSFP imaging and parallel-transmission universal pulses
    Leroi, Lisa
    Gras, Vincent
    Boulant, Nicolas
    Ripart, Mathilde
    Poirion, Emilie
    Santin, Mathieu D.
    Valabregue, Romain
    Mauconduit, Franck
    Hertz-Pannier, Lucie
    Le Bihan, Denis
    de Rochefort, Ludovic
    Vignaud, Alexandre
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3286 - 3299
  • [24] Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI
    Yu, Nan
    Duan, Haifeng
    Yang, Chuangbo
    Yu, Yong
    Dang, Shan
    CANCER IMAGING, 2021, 21 (01)
  • [25] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [26] Combination of free-breathing radial 3D fat-suppressed T1-weighted gradient-echo sequence with diffusion weighted images: Potential for differentiating malignant from benign peripheral solid pulmonary masses
    Dang, Shan
    Gao, Xiang
    Ma, Guangming
    Yu, Nan
    Han, Dong
    Yang, Qi
    Tian, Xin
    Duan, Haifeng
    MAGNETIC RESONANCE IMAGING, 2019, 57 : 271 - 276
  • [27] Free-running 3D whole-heart T1 and T2 mapping and cine MRI using low-rank reconstruction with non-rigid cardiac motion correction
    Phair, Andrew
    Cruz, Gastao
    Qi, Haikun
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 217 - 232