Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma

被引:48
作者
Baffour, Francis I. [1 ]
Huber, Nathan R. [1 ]
Ferrero, Andrea [1 ]
Rajendran, Kishore [1 ]
Glazebrook, Katrina N. [1 ]
Larson, Nicholas B. [2 ]
Kumar, Shaji [3 ]
Cook, Joselle M. [3 ]
Leng, Shuai [1 ]
Shanblatt, Elisabeth R. [4 ]
McCollough, Cynthia H. [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Dept Quantitat Hlth Sci, 200 First St SW, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Med, Div Hematol, 200 First St SW, Rochester, MN 55905 USA
[4] Siemens Med Solut USA, Malvern, PA USA
关键词
CRITERIA;
D O I
10.1148/radiol.220311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT.Purpose: To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods: Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thick-ness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT imag-es were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results: Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 partici-pants compared with the 2-mm EID CT images (P < .001). Conclusion: Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 22 条
[1]   Role of imaging in multiple myeloma [J].
Baffour, Francis I. ;
Glazebrook, Katrina N. ;
Kumar, Shaji K. ;
Broski, Stephen M. .
AMERICAN JOURNAL OF HEMATOLOGY, 2020, 95 (08) :966-977
[2]   Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT [J].
Flohr, T. G. ;
Stierstorfer, K. ;
Suess, C. ;
Primak, A. N. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2007, 34 (05) :1712-1723
[3]   Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI) [J].
Gleeson, T. G. ;
Moriarty, J. ;
Shortt, C. P. ;
Gleeson, J. P. ;
Fitzpatrick, P. ;
Byrne, B. ;
McHugh, J. ;
O'Connell, M. ;
O'Gorman, P. ;
Eustace, S. J. .
SKELETAL RADIOLOGY, 2009, 38 (03) :225-236
[4]   Image Quality Assessment for Clinical Cadmium Telluride-Based Photon-Counting Computed Tomography Detector in Cadaveric Wrist Imaging [J].
Grunz, Jan-Peter ;
Huflage, Henner ;
Heidenreich, Julius Frederik ;
Erguen, Suleyman ;
Petersilka, Martin ;
Allmendinger, Thomas ;
Bley, Thorsten Alexander ;
Petritsch, Bernhard .
INVESTIGATIVE RADIOLOGY, 2021, 56 (12) :785-790
[5]   Organ dose and total effective dose of whole-body CT in multiple myeloma patients [J].
Hemke, Robert ;
Yang, Kai ;
Husseini, Jad ;
Bredella, Miriam A. ;
Simeone, F. Joseph .
SKELETAL RADIOLOGY, 2020, 49 (04) :549-554
[6]   Location and direction dependence in the 3D MTF for a high-resolution CT system [J].
Hernandez, Andrew M. ;
Wu, Pengwei ;
Mahesh, Mahadevappa ;
Siewerdsen, Jeffrey H. ;
Boone, John M. .
MEDICAL PHYSICS, 2021, 48 (06) :2760-2771
[7]   International myeloma working group consensus recommendations on imaging in monoclonal plasma cell disorders [J].
Hillengass, Jens ;
Usmani, Saad ;
Rajkumar, S. Vincent ;
Durie, Brian G. M. ;
Mateos, Maria-Victoria ;
Lonial, Sagar ;
Joao, Cristina ;
Anderson, Kenneth C. ;
Garcia-Sanz, Ramon ;
Riva Serra, Eloisa ;
Du, Juan ;
van de Donk, Niels ;
Berdeja, Jesus G. ;
Terpos, Evangelos ;
Zamagni, Elena ;
Kyle, Robert A. ;
San Miguel, Jesus ;
Goldschmidt, Hartmut ;
Giralt, Sergio ;
Kumar, Shaji ;
Raje, Noopur ;
Ludwig, Heinz ;
Ocio, Enrique ;
Schots, Rik ;
Einsele, Hermann ;
Schjesvold, Fredrik ;
Chen, Wen-Ming ;
Abildgaard, Niels ;
Lipe, Brea C. ;
Dytfeld, Dominik ;
Wirk, Baldeep Mona ;
Drake, Matthew ;
Cavo, Michele ;
Jose Lahuerta, Juan ;
Lentzsch, Suzanne .
LANCET ONCOLOGY, 2019, 20 (06) :E302-E312
[8]   Clinical evaluation of a phantom-based deep convolutional neural network for whole-body-low-dose and ultra-low-dose CT skeletal surveys [J].
Huber, Nathan ;
Anderson, Tara ;
Missert, Andrew ;
Adkins, Mark ;
Leng, Shuai ;
Fletcher, Joel ;
McCollough, Cynthia ;
Yu, Lifeng ;
Glazebrook, Katrina N. .
SKELETAL RADIOLOGY, 2022, 51 (01) :145-151
[9]   Efficacy of multidetector row computed tomography of the spine in patients with multiple myeloma: Comparison with magnetic resonance imaging and fluorodeoxyglucose-positron emission tomography [J].
Hur, Jin ;
Yoon, Choon-Sik ;
Ryu, Young Hoon ;
Yun, Mi Jin ;
Suh, Jin-Suck .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (03) :342-347
[10]   Bone microarchitectural analysis using ultra-high-resolution CT in tiger vertebra and human tibia [J].
Inai, Ryota ;
Nakahara, Ryuichi ;
Morimitsu, Yusuke ;
Akagi, Noriaki ;
Marukawa, Youhei ;
Matsushita, Toshi ;
Tanaka, Takashi ;
Tada, Akihiro ;
Hiraki, Takao ;
Nasu, Yoshihisa ;
Nishida, Keiichiro ;
Ozaki, Toshifumi ;
Kanazawa, Susumu .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)