CO2 Measurement under Different Pressure and Vibration Conditions Using Tunable Diode Laser Absorption Spectroscopy

被引:1
|
作者
Ban, Deyue [1 ]
Li, Nan [1 ]
Zheng, Yongqiu [1 ]
Xue, Chenyang [1 ]
机构
[1] North Univ China, State Key Lab Dynam Measurement Technol, Taiyuan 030051, Peoples R China
关键词
tunable laser absorption spectroscopy; WMS; pressure; vibration; flue gas duct; TEMPERATURE; TDLAS;
D O I
10.3390/photonics11020146
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The greenhouse effect resulting from fuel combustion has drawn growing attention, and CO2 emissions from fossil fuel power stations are one of the main sources of greenhouse gases. It is crucial to monitor the concentration of CO2 in the flue gas ducts of these stations. However, pressure and vibration caused by the combustion of boilers make the measurement of CO2 in flue gas ducts extremely challenging. In this study, tunable diode laser absorption spectroscopy (TDLAS) combined with Wave Modulation Spectroscopy (WMS) was employed to measure the concentration of CO2 under different pressure and vibration conditions in the laboratory. The absorption line of CO2 at the wavenumber 6357.38 cm(-1) was recorded under varying pressure conditions ranging from 0 to 1.4 atm, acceleration conditions ranging from 0 to 7.7 m/s(2), and a combination of both. Firstly, a negative linear correlation was found between the pressure and the amplitude of the second harmonic, with a maximum relative error of 4.645% observed at a pressure of 1.4 atm. Secondly, the maximum acceleration that the system can withstand was determined to be 7.3 m/s(2), as it was not possible to provide a sufficiently low fitting error at higher accelerations. For the combined effects of the pressure and vibration, a dramatic increase in the relative error of amplitude can be observed within the acceleration range of 5.0 similar to 6.0 m/s(2) while under the pressure conditions of 0.6 atm, 1.0 atm, and 1.4 atm. Moreover, the maximum endurable acceleration decreases with the increase in pressure, which infers that effective measurements can be achieved when the acceleration is below 5 m/s(2) within the pressure range of 0 similar to 1.4 atm. This suggests that TDLAS combined with WMS possesses a potential for online measuring of CO2 concentrations in flue gas ducts within a certain acceleration range. This work can provide some insights for stable gas detection using TDLAS under varied pressure and vibration conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Temperature and Pressure Measurement based on Tunable Diode Laser Absorption Spectroscopy with gas absorption Linewidth Detection
    Meng, Yunxia
    Liu, Tiegen
    Liu, Kun
    Jiang, Junfeng
    Wang, Tao
    Wang, Ranran
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VI, 2014, 9274
  • [22] Measurement of Oxygen concentration using tunable diode laser absorption spectroscopy and wavelength modulation spectroscopy
    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
    Zhongguo Jiguang, 2008, 10 (1558-1562):
  • [23] Optimization for hydrogen gas quantitative measurement using tunable diode laser absorption spectroscopy
    Xiafukaiti, Alifu
    Lagrosas, Nofel
    Ogita, Masakazu
    Oi, Nobuhiko
    Ichikawa, Yuji
    Sugimoto, Sachiyo
    Asahi, Ippei
    Yamaguchi, Shigeru
    Shiina, Tatsuo
    OPTICS AND LASER TECHNOLOGY, 2025, 180
  • [24] Using tunable diode laser spectroscopy to measure carbon isotope discrimination and mesophyll conductance to CO2 diffusion dynamically at different CO2 concentrations
    Tazoe, Youshi
    Von Caemmerer, Susanne
    Estavillo, Gonzalo M.
    Evans, John R.
    PLANT CELL AND ENVIRONMENT, 2011, 34 (04): : 580 - 591
  • [25] Tunable Diode Laser Atomic Absorption Spectroscopy for Detection of Potassium under Optically Thick Conditions
    Qu, Zhechao
    Steinvall, Erik
    Ghorbani, Ramin
    Schmidt, Florian M.
    ANALYTICAL CHEMISTRY, 2016, 88 (07) : 3754 - 3760
  • [26] Measurement on gas temperature distribution by tunable diode laser absorption spectroscopy
    State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China
    Guang Pu Xue Yu Guang Pu Fen Xi, 2008, 8 (1708-1712):
  • [27] Ethanol vapor measurement based on tunable diode laser absorption spectroscopy
    Geng Hui
    Liu Jian-Guo
    Zhang Yu-Jun
    Kan Rui-Feng
    Xu Zhen-Yu
    Yao Lu
    Ruan Jun
    ACTA PHYSICA SINICA, 2014, 63 (04)
  • [28] Measurement on gas temperature distribution by tunable diode laser absorption Spectroscopy
    Li Ning
    Yan Jian-hua
    Wang Fei
    Chi Yong
    Cen Ke-fa
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1708 - 1712
  • [29] The use of tunable diode laser absorption spectroscopy for the measurement of flame dynamics
    Hendricks, AG
    Vandsburger, U
    Saunders, WR
    Baumann, WT
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (01) : 139 - 144
  • [30] Entropy transfer function measurement with tunable diode laser absorption spectroscopy
    Dharmaputra, Bayu
    Shcherbanev, Sergey
    Blonde, Audrey
    Schuermans, Bruno
    Noiray, Nicolas
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2023, 39 (04) : 4621 - 4630