CO2 Measurement under Different Pressure and Vibration Conditions Using Tunable Diode Laser Absorption Spectroscopy

被引:1
|
作者
Ban, Deyue [1 ]
Li, Nan [1 ]
Zheng, Yongqiu [1 ]
Xue, Chenyang [1 ]
机构
[1] North Univ China, State Key Lab Dynam Measurement Technol, Taiyuan 030051, Peoples R China
关键词
tunable laser absorption spectroscopy; WMS; pressure; vibration; flue gas duct; TEMPERATURE; TDLAS;
D O I
10.3390/photonics11020146
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The greenhouse effect resulting from fuel combustion has drawn growing attention, and CO2 emissions from fossil fuel power stations are one of the main sources of greenhouse gases. It is crucial to monitor the concentration of CO2 in the flue gas ducts of these stations. However, pressure and vibration caused by the combustion of boilers make the measurement of CO2 in flue gas ducts extremely challenging. In this study, tunable diode laser absorption spectroscopy (TDLAS) combined with Wave Modulation Spectroscopy (WMS) was employed to measure the concentration of CO2 under different pressure and vibration conditions in the laboratory. The absorption line of CO2 at the wavenumber 6357.38 cm(-1) was recorded under varying pressure conditions ranging from 0 to 1.4 atm, acceleration conditions ranging from 0 to 7.7 m/s(2), and a combination of both. Firstly, a negative linear correlation was found between the pressure and the amplitude of the second harmonic, with a maximum relative error of 4.645% observed at a pressure of 1.4 atm. Secondly, the maximum acceleration that the system can withstand was determined to be 7.3 m/s(2), as it was not possible to provide a sufficiently low fitting error at higher accelerations. For the combined effects of the pressure and vibration, a dramatic increase in the relative error of amplitude can be observed within the acceleration range of 5.0 similar to 6.0 m/s(2) while under the pressure conditions of 0.6 atm, 1.0 atm, and 1.4 atm. Moreover, the maximum endurable acceleration decreases with the increase in pressure, which infers that effective measurements can be achieved when the acceleration is below 5 m/s(2) within the pressure range of 0 similar to 1.4 atm. This suggests that TDLAS combined with WMS possesses a potential for online measuring of CO2 concentrations in flue gas ducts within a certain acceleration range. This work can provide some insights for stable gas detection using TDLAS under varied pressure and vibration conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Tunable diode laser absorption spectroscopy on 2.05 μm for the CO2 concentration measurement
    Pranovich, Alina
    Divoky, Martin
    Prochazka, Ivan
    Mocek, Tomas
    OPTICAL SENSORS 2015, 2015, 9506
  • [2] Study on CO2 Measurement Using Tunable Multi-Mode Diode Laser Absorption Spectroscopy
    Gao Guang-zhen
    Chen Bao-xue
    Hu Bo
    Long Xiu-hui
    Li Ai-ping
    Li Rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (12) : 3269 - 3272
  • [3] Volcanic CO2 flux measurement at Campi Flegrei by tunable diode laser absorption spectroscopy
    Pedone, M.
    Aiuppa, A.
    Giudice, G.
    Grassa, F.
    Cardellini, C.
    Chiodini, G.
    Valenza, M.
    BULLETIN OF VOLCANOLOGY, 2014, 76 (04) : 1 - 13
  • [4] Volcanic CO2 flux measurement at Campi Flegrei by tunable diode laser absorption spectroscopy
    M. Pedone
    A. Aiuppa
    G. Giudice
    F. Grassa
    C. Cardellini
    G. Chiodini
    M. Valenza
    Bulletin of Volcanology, 2014, 76
  • [5] Measurements of CO2 Concentration at High Temperature and Pressure Environments Using Tunable Diode Laser Absorption Spectroscopy
    Cai Ting-dong
    Gao Guang-zhen
    Wang Min-rui
    Wang Gui-shi
    Gao Xiao-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (07) : 1769 - 1773
  • [6] Measurement of CO2 concentration at high-temperature based on tunable diode laser absorption spectroscopy
    Chen, Jiuying
    Li, Chuanrong
    Zhou, Mei
    Liu, Jianguo
    Kan, Ruifeng
    Xu, Zhenyu
    INFRARED PHYSICS & TECHNOLOGY, 2017, 80 : 131 - 137
  • [7] CO2 Detection Based on Infrared Tunable Diode Laser Absorption Spectroscopy
    Wei Li
    Zhang Fan
    Liu Zhigang
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1-2, 2008, : 443 - 446
  • [8] Remote Detection of Breath CO2 with Tunable Diode Laser Absorption Spectroscopy
    Wright, A. O.
    Frish, M. B.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1473 - 1473
  • [9] Highly sensitive tunable diode laser absorption spectroscopy of CO2 around 1.31 μm
    Laboratory of Atmospheric Optics, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    Guang Pu Xue Yu Guang Pu Fen Xi, 2006, 2 (213-217):
  • [10] Highly sensitive tunable diode laser absorption spectroscopy of CO2 around 1.31 μm
    Shao, J
    Gao, XM
    Deng, LH
    Huang, W
    Yang, Y
    Pei, SX
    Yuan, YQ
    Zhang, WJ
    CHINESE PHYSICS LETTERS, 2004, 21 (10) : 1908 - 1910