Behaviour of T-shaped stiffened concrete-filled steel tubular stub columns after uniform and non-uniform fire exposure

被引:1
作者
Lyu, Xuetao [1 ,2 ]
Li, Ying [3 ]
Wang, Weiwei [4 ]
Liu, Faqi [2 ,5 ,7 ]
Xu, Yang [6 ]
机构
[1] Foshan Univ, Sch Transportat & Civil Engn & Architecture, Adv & Sustainable Infrastruct Mat Grp, Foshan, Peoples R China
[2] Minist Educat, Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Harbin, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin, Peoples R China
[4] Guangzhou Vocat & Tech Univ Sci & Technol, Sch Architectural Engn, Guangzhou, Peoples R China
[5] Minist Ind & Informat Technol, Harbin Inst Technol, Key Lab Smart Prevent Mitigat Civil Engn Disasters, Harbin, Peoples R China
[6] Liaoning Tech Univ, Sch Civil Engn, Fuxin, Peoples R China
[7] Minist Educ, Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
t-shaped stiffened concrete-filled steel tubular stub columns; post-fire; residual bearing capacity; axial compression stiffness; ductility index; SEISMIC BEHAVIORS; STATIC BEHAVIOR; RHS COLUMNS; PERFORMANCE; STRENGTH;
D O I
10.1177/13694332231214999
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire behaviour of T-shaped stiffened concrete-filled steel tubular stub columns was investigated by the heating and residual mechanical performance tests. Key parameters, such as heating duration, number of surfaces exposed to fire and the influence of the stiffening steel bars, were studied. Temperature distribution, failure modes, mid-height strain curves, and load-displacement curves were obtained and discussed. The study reveals that the number of fire-exposure surfaces significantly affects the temperature distribution of the specimen section. Both the bearing capacity and compressive stiffness decrease with the increase of fire exposure surfaces and heating time, whereas the ductility follows an inverse pattern. The transverse stiffeners can enhance the mechanical performance of these stub columns, especially for ductility.
引用
收藏
页码:72 / 84
页数:13
相关论文
共 35 条
[1]  
Chen Z., 2000, J BUILD STRUCT, V21, P2
[2]  
China National Emergency Broadcasting, 2017, NAT FIR ACC STAT 201
[3]  
GB/T 50081-2019, 2019, STANDARD TEST METHOD
[4]  
Guo Z, 2011, EXPERIMENT AND CALCULATION OF REINFORCED CONCRETE AT ELEVATED TEMPERATURES, P1
[5]  
HAN L.H., 2007, Concrete-filled steel tubular structure-Theory and Practice
[6]   Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard [J].
Han, LH ;
Huo, JS .
JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (01) :68-78
[7]   Residual strength of concrete-filled RHS columns after exposure to the ISO-834 standard fire [J].
Han, LH ;
Yang, YF ;
Yang, H ;
Huo, JS .
THIN-WALLED STRUCTURES, 2002, 40 (12) :991-1012
[8]   Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members [J].
Han, Lin-Hai ;
Li, Wei ;
Bjorhovde, Reidar .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 100 :211-228
[9]   Cyclic behaviours of concrete-filled steel tubular columns with pre-load after exposure to fire [J].
Huo, Jingsi ;
Zeng, Xiang ;
Xiao, Yan .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (04) :727-739
[10]  
ISO-12570:2000, 2000, ISO125702000