Experimental analysis of heat exchanger using perforated conical rings, twisted tape inserts and CuO/H2O nanofluids

被引:13
|
作者
Kumar, Anil [1 ]
Ali, Masood Ashraf [2 ]
Maithani, Rajesh [1 ]
Gupta, Naveen Kumar [3 ]
Sharma, Sachin [1 ]
Kumar, Sunil [4 ]
Sharma, Lohit [5 ]
Thakur, Robin [5 ]
Alam, Tabish [6 ]
Dobrota, Dan [7 ]
Eldin, Sayed M. [8 ]
机构
[1] UPES, Mech Engn Dept, Dehra Dun 248007, Uttarakhand, India
[2] Prince Sattam Bin Abdulaziz Univ, Coll Engn, Dept Ind Engn, Al Kharj 11942, Saudi Arabia
[3] GLA Univ, Inst Engn & Technol, Mathura 281406, India
[4] Shoolini Univ, Yogananda Sch Artificial Intelligence Comp & Data, Solan 173229, India
[5] Shoolini Univ, Sch Core Engn, Solan, India
[6] CSIR Cent Bldg Res Inst, Roorkee 247667, India
[7] Lucian Blaga Univ Sibiu, Fac Engn, Dept Ind Engn & Management, Sibiu 550024, Romania
[8] Future Univ Egypt, Fac Engn, Ctr Res, New Cairo 11835, Egypt
关键词
Nanofluid; Heat exchanger; Nusselt number; Twisted tape; Thermohydraulic performance; TRANSFER ENHANCEMENT; FRICTION FACTOR; TUBE; FLOW; PERFORMANCE; CONVECTION; SINGLE;
D O I
10.1016/j.csite.2023.103255
中图分类号
O414.1 [热力学];
学科分类号
摘要
This research paper presents an experimental analysis on a heat exchanger tube using a newly designed perforated conical ring combined with twisted tape as inserts. The investigation analyzes various geometric and flow parameters in the experimental setup, including a wide range of Reynolds numbers, varying from 6000 to 30000, nanoparticle volume concentration (& phi;np) of 0.251.0%, the ratio of inlet flow dia to inner print dia of the ring (DIR /DBR) of 1.33-2.33, ring pitch ratio (RP/ DED) of 1.41-2.51, twist ratio (TL/ WT) of 3.33-4.38, with fixed values for other parameters: relative ring height ((DED/ WR) of 2.33 and nanoparticle diameter (dnp) of 30 nm. The optimal result of the thermal-hydraulic performance parameter (& eta;TT) is 1.45 at DIR/DBR = 1.83, TL/ WT = 3.50 and RP/ DED = 1.76. For the CuO/H2O nanofluids flow heat exchanger tube with perforated conical rings, empirical correlations were developed for the Nusselt number and the friction factor. These correlations were established with a range of 9.0% and 8.0%, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Experimental Study of Double Pipe Heat Exchanger Performance Equipped with Perforated Twisted Tape Considering Various Twist Ratio
    Ariwibowo, Teguh Hady
    Permatasari, Prima Dewi
    Kurniawan, Ardika
    2017 INTERNATIONAL ELECTRONICS SYMPOSIUM ON ENGINEERING TECHNOLOGY AND APPLICATIONS (IES-ETA), 2017, : 203 - 206
  • [22] Improving hydrothermal performance of double-tube heat exchanger with modified twisted tape inserts using hybrid nanofluid
    Singh, Sumit Kr.
    Sarkar, Jahar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 143 (06) : 4287 - 4298
  • [23] Experimental investigation of a solar desalination system using twisted tape and wire coil inside of spiral heat exchanger
    Hosseini, Seyed Sharifodin
    Farhadi, Mousa
    Sedighi, Kurosh
    DESALINATION, 2017, 420 : 34 - 44
  • [24] Experimental investigation on enhancement of heat transfer using Al2O3/water nanofluid in a u-tube with twisted tape inserts
    Prasad, P. V. Durga
    Gupta, A. V. S. S. K. S.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 75 : 154 - 161
  • [25] Effect of twisted tape inserts on heat transfer, friction factor of Fe3O4 nanofluids flow in a double pipe U-bend heat exchanger
    Kumar, N. T. Ravi
    Bhramara, P.
    Kirubeil, A.
    Syam Sundar, L.
    Singh, Manoj K.
    Sousa, Antonio C. M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 95 : 53 - 62
  • [26] A comprehensive second law analysis for a heat exchanger tube equipped with the rod inserted straight and twisted tape and using water/CuO nanofluid
    Dagdevir, Toygun
    Ozceyhan, Veysel
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 181
  • [27] ENHANCING THE THERMAL PERFORMANCE OF A MICRO FINNED TUBE WITH TiO2-WATER NANOFLUIDS USING TWISTED TAPE INSERTS
    Mageshbabu, D.
    Kabeel, A. E.
    Sathyamurthy, Ravishankar
    El-Agouz, S. A.
    Chamkha, Ali J.
    Girija, M. S.
    Madhu, B.
    HEAT TRANSFER RESEARCH, 2019, 50 (09) : 851 - 863
  • [28] Experimental investigation of heat transfer and fluid flow behaviour in multiple square perforated twisted tape with square wing inserts heat exchanger tube
    Suri, Amar Raj Singh
    Kumar, Anil
    Maithani, Rajesh
    HEAT AND MASS TRANSFER, 2018, 54 (06) : 1813 - 1826
  • [29] Experimental evaluation and thermal performance analysis of a twisted tape with dimple configuration in a heat exchanger
    Heeraman, Jatoth
    Kumar, Ravinder
    Chaurasiya, Prem Kumar
    Beloev, Hristo Ivanov
    Iliev, Iliya Krastev
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 46
  • [30] EXPERIMENTAL INVESTIGATION OF ENHANCING INFLUENCE OF Al2O3 NANOPARTICLES ON THE CONVECTIVE HEAT TRANSFER IN A TUBE EQUIPPED WITH TWISTED TAPE INSERTS
    Mozaffari, Javad
    Mirjalily, Seyed Ali Agha
    Ahrar, Amir Javad
    THERMAL SCIENCE, 2021, 25 (01): : 541 - 551