The evaluation of an on-site monitoring program for activity meter quality assurance with exemption-level sources

被引:0
|
作者
Feng, Chen-Ju [1 ,2 ]
Wu, Chin-Hui [3 ]
Lin, Chin-Hsiung [1 ,2 ,4 ]
Yuan, Ming-Chen [5 ]
Lee, Shen-Hao [6 ,7 ]
Huang, David Y. C. [8 ]
Lin, Jo-Yu [1 ,2 ]
Chen, Ying-Fang [1 ,2 ]
Hsu, Shih-Ming [1 ,2 ,7 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Med Phys & Radiat Measurements Lab, Taipei, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[3] Tzu Chi Univ Sci & Technol, Dept Med Imaging & Radiol Sci, Hualien, Taiwan
[4] Koo Fdn Sun Yat Sen Canc Ctr, Dept Med Phys, Taipei, Taiwan
[5] Inst Nucl Energy Res, Hlth Phys Div, Taoyuan City, Taiwan
[6] Chang Gung Mem Hosp, Dept Radiat Oncol, Taoyuan City, Taiwan
[7] Chinese Soc Med Phys, Taipei, Taiwan
[8] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Jiangsu, Peoples R China
关键词
activity meter; quality assurance; questionnaire; on-site visit; exemption-level source; NUCLEAR-MEDICINE; DOSIMETRY; CALIBRATORS;
D O I
10.1088/1361-6498/accc96
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper discusses the feasibility of a monitoring program for the quality assurance status of activity meters. We sent a questionnaire to clinical nuclear medicine departments of medical institutions, requesting information on their activity meters and quality assurance practices. On-site visits were conducted with exemption-level standard sources (Co-57, Cs-137 and Ba-133) for dose calibrators in nuclear medicine departments including physical inspection, accuracy and reproducibility. A method offering a quick check on the detection efficiency of the space dimension inside the activity meters was also introduced. For dose calibrator quality assurance, the daily checks had the highest implementation. However, annual checks and upon acceptance/after a repair check were reduced to 50% and 44%, respectively. The accuracy results of dose calibrators showed that all models exceeded the +/- 10% criteria with Co-57 and Cs-137 sources. The reproducibility results showed that some models exceeded the +/- 5% criteria with Co-57 and Cs-137 sources. The appropriate application of exemption-level standard sources considering the uncertainty that affects the measurement is discussed.
引用
收藏
页数:10
相关论文
共 7 条
  • [1] Nutrition Program Quality Assurance through a Formalized Process of On-site Program Review
    Paddock, Joan Doyle
    Dollahite, Jamie
    JOURNAL OF NUTRITION EDUCATION AND BEHAVIOR, 2012, 44 (02) : 183 - 188
  • [2] Quality assurance in an epidemiological cohort study: on-site monitoring in gynaecological practices
    Zeissig, Sylke R.
    Radde, Kathrin
    Kaiser, Melanie
    Blettner, Maria
    Klug, Stefanie J.
    ZEITSCHRIFT FUR EVIDENZ FORTBILDUNG UND QUALITAET IM GESUNDHEITSWESEN, 2014, 108 (8-9): : 517 - 527
  • [3] Rapid on-site evaluation using telecytology: Quality assurance study at a high-volume cancer center
    Alhamar, Mohamed
    Rudomina, Dorota
    Wang, Lu
    Feratovic, Rusmir
    Oen, Handy
    Lin, Oscar
    Wei, Xiao-Jun
    CANCER CYTOPATHOLOGY, 2025, 133 (01)
  • [4] Rapid On-Site Evaluation Technical Exercise Using Digital Pathology: Peer Comparison in an External Quality Assurance Setting
    Greaves, Janelle
    Pagliuso, Julia
    Ross, Jennifer
    Badrick, Tony
    ACTA CYTOLOGICA, 2022, 66 (03) : 235 - 243
  • [5] Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules
    Bak, Mihaly
    Hidvegi, Judit
    Andi, Judit
    Bahery, Maria
    Kovacs, Eszter
    Schneider, Ferenc
    Kostic, Szilard
    Renyi-Vamos, Ferenc
    Szoke, Janos
    Nyari, Tibor
    Godeny, Maria
    Kasler, Miklos
    ORVOSI HETILAP, 2013, 154 (01) : 28 - 32
  • [6] Evaluation of an emergency radiology quality assurance program at a level I trauma center: Abdominal and pelvic CT studies
    Yoon, LS
    Haims, AH
    Brink, JA
    Rabinovici, R
    Forman, HP
    RADIOLOGY, 2002, 224 (01) : 42 - 46