Time-resolved Fluorescence DNA-based Sensors for Reducing Background Fluorescence of Environment

被引:5
|
作者
Esmaelpourfarkhani, Masoomeh [1 ,2 ]
Ramezani, Mohammad [3 ]
Alibolandi, Mona [3 ]
Abnous, Khalil [3 ]
Taghdisi, Seyed Mohammad [1 ,4 ]
机构
[1] Mashhad Univ Med Sci, Pharmaceut Technol Inst, Targeted Drug Delivery Res Ctr, Mashhad, Iran
[2] Mashhad Univ Med Sci, Sch Pharm, Dept Med Chem, Mashhad, Iran
[3] Mashhad Univ Med Sci, Pharmaceut Technol Inst, Pharmaceut Res Ctr, Mashhad, Iran
[4] Mashhad Univ Med Sci, Sch Pharm, Dept Pharmaceut Biotechnol, Mashhad, Iran
关键词
Time-resolved fluorescence; Complexes of lanthanide ions; Aptasensor; Lanthanide-doped inorganic nanoparticles; Mn-doped ZnS QDs; Pyrene excimer; ENERGY-TRANSFER; QUANTUM DOTS; LABEL-FREE; ULTRASENSITIVE DETECTION; COLORIMETRIC APTASENSOR; SENSITIZED LUMINESCENCE; OPTICAL SPECTROSCOPY; GOLD NANOPARTICLE; EUROPIUM CHELATE; SPLIT APTAMER;
D O I
10.1007/s10895-023-03239-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fluorescence assay is one of the popular methods that is applied for detection of different targets. However, this method may show low sensitivity and high background in biological samples due to the natural fluorescence of different compounds in complicated samples. In addition, it inevitably affects the detection results accuracy. A fundamental solution to this problem is the use of the time-resolved fluorescence technique (TRF). The main component of this technique is the use of long fluorescence lifetime reagents. In this review, various time-resolved fluorescent reagents such as complexes of lanthanide ions, lanthanide-doped inorganic nanoparticles; Mn-doped ZnS quantum dots (QDs) and pyrene excimer are introduced. Moreover, TRF sensors, especially TRF aptasensors (DNA-based sensors) are discussed. This review will give new ideas for researchers to develop novel high-sensitive TRF sensors that can remove or decrease background fluorescence and use them for the detection of various targets in complicated samples without treatment.
引用
收藏
页码:2145 / 2160
页数:16
相关论文
共 50 条
  • [41] Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument
    Guo, ZY
    Tian, Z
    Jia, YL
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 222 - 226
  • [42] Preparation and time-resolved fluorescence study of RGB organic crystals
    Fang, Hong-Hua
    Lu, Shi-Yang
    Wang, Lei
    Ding, Ran
    Wang, Hai-Yu
    Feng, Jing
    Chen, Qi-Dai
    Sun, Hong-Bo
    ORGANIC ELECTRONICS, 2013, 14 (01) : 389 - 395
  • [43] DIRECT TIME-RESOLVED FLUORESCENCE IMMUNOASSAY FOR SERUM ESTRADIOL BASED ON THE IDIOTYPIC ANTIIDIOTYPIC APPROACH
    ALTAMIRANOBUSTAMANTE, A
    BARNARD, G
    KOHEN, F
    JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 138 (01) : 95 - 101
  • [44] A Compact Analog Histogramming SPAD-Based CMOS Chip for Time-Resolved Fluorescence
    Dieguez, Angel
    Canals, Joan
    Franch, Nil
    Dieguez, Joel
    Alonso, Oscar
    Vila, Anna
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (02) : 343 - 351
  • [45] Determination of ammonia-oxidizing bacteria based on time-resolved fluorescence and tandem probe
    Lv, Xiaoxiao
    Li, Zhizhang
    Niu, Chenggang
    Ruan, Min
    Hang, Dawei
    Zeng, Guangming
    WATER SCIENCE AND TECHNOLOGY, 2012, 66 (06) : 1361 - 1368
  • [46] The use of time-resolved fluorescence in gel-based proteomics for improved biomarker discovery
    Sandberg, AnnSofi
    Buschmann, Volker
    Kapusta, Peter
    Erdmann, Rainer
    Wheelock, Asa M.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VIII, 2010, 7568
  • [47] Lanthanide-based time-resolved fluorescence of in cyto ligand-receptor interactions
    Handl, HL
    Vagner, J
    Yamamura, HI
    Hruby, VJ
    Gillies, RJ
    ANALYTICAL BIOCHEMISTRY, 2004, 330 (02) : 242 - 250
  • [48] Real time optical Biopsy: Time-resolved Fluorescence Spectroscopy instrumentation and validation
    Kittle, David S.
    Vasefi, Fartash
    Patil, Chirag G.
    Mamelak, Adam
    Black, Keith L.
    Butte, Pramod V.
    SCIENTIFIC REPORTS, 2016, 6
  • [49] 340 nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection
    Rodenko, Olga
    Fodgaard, Henrik
    Tidemand-Lichtenberg, Peter
    Pedersen, Christian
    OPTICAL DIAGNOSTICS AND SENSING XVII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2017, 10072
  • [50] Analytical performances of a DNA-ligand system using time-resolved fluorescence for the determination of ochratoxin A in wheat
    De Girolamo, Annalisa
    Le, Linda
    Penner, Gregory
    Schena, Roberto
    Visconti, Angelo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (09) : 2627 - 2634